<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v2.0 20040830//EN" "http://dtd.nlm.nih.gov/publishing/2.0/journalpublishing.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" article-type="research-article" dtd-version="2.0">
  <front>
    <journal-meta>
      <journal-id journal-id-type="publisher-id">JMIR Human Factors</journal-id>
      <journal-id journal-id-type="nlm-ta">JMIR Hum Factors</journal-id>
      <journal-title>JMIR Human Factors</journal-title>
      <issn pub-type="epub">2292-9495</issn>
      <publisher>
        <publisher-name>JMIR Publications</publisher-name>
        <publisher-loc>Toronto, Canada</publisher-loc>
      </publisher>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="publisher-id">v10i1e48270</article-id>
      <article-id pub-id-type="pmid">37535417</article-id>
      <article-id pub-id-type="doi">10.2196/48270</article-id>
      <article-categories>
        <subj-group subj-group-type="heading">
          <subject>Original Paper</subject>
        </subj-group>
        <subj-group subj-group-type="article-type">
          <subject>Original Paper</subject>
        </subj-group>
      </article-categories>
      <title-group>
        <article-title>Accuracy and Reliability of a Suite of Digital Measures of Walking Generated Using a Wrist-Worn Sensor in Healthy Individuals: Performance Characterization Study</article-title>
      </title-group>
      <contrib-group>
        <contrib contrib-type="editor">
          <name>
            <surname>Eysenbach</surname>
            <given-names>Gunther</given-names>
          </name>
        </contrib>
        <contrib contrib-type="editor">
          <name>
            <surname>Kushniruk</surname>
            <given-names>Andre</given-names>
          </name>
        </contrib>
      </contrib-group>
      <contrib-group>
        <contrib contrib-type="reviewer">
          <name>
            <surname>Bennasar</surname>
            <given-names>Mohamed</given-names>
          </name>
        </contrib>
        <contrib contrib-type="reviewer">
          <name>
            <surname>Peterson</surname>
            <given-names>Barry</given-names>
          </name>
        </contrib>
      </contrib-group>
      <contrib-group>
        <contrib id="contrib1" contrib-type="author" corresp="yes" equal-contrib="yes">
          <name name-style="western">
            <surname>Kowahl</surname>
            <given-names>Nathan</given-names>
          </name>
          <degrees>MS</degrees>
          <xref rid="aff1" ref-type="aff">1</xref>
          <address>
            <institution>Verily Life Sciences</institution>
            <addr-line>269 E Grand Ave</addr-line>
            <addr-line>South San Francisco, CA, 94080</addr-line>
            <country>United States</country>
            <phone>1 415 504 2681</phone>
            <email>natekowahl@verily.com</email>
          </address>
          <ext-link ext-link-type="orcid">https://orcid.org/0000-0002-7049-4793</ext-link>
        </contrib>
        <contrib id="contrib2" contrib-type="author" equal-contrib="yes">
          <name name-style="western">
            <surname>Shin</surname>
            <given-names>Sooyoon</given-names>
          </name>
          <degrees>PhD</degrees>
          <xref rid="aff1" ref-type="aff">1</xref>
          <ext-link ext-link-type="orcid">https://orcid.org/0000-0002-0339-4856</ext-link>
        </contrib>
        <contrib id="contrib3" contrib-type="author">
          <name name-style="western">
            <surname>Barman</surname>
            <given-names>Poulami</given-names>
          </name>
          <degrees>MS</degrees>
          <xref rid="aff1" ref-type="aff">1</xref>
          <ext-link ext-link-type="orcid">https://orcid.org/0000-0002-4604-9868</ext-link>
        </contrib>
        <contrib id="contrib4" contrib-type="author">
          <name name-style="western">
            <surname>Rainaldi</surname>
            <given-names>Erin</given-names>
          </name>
          <degrees>MS</degrees>
          <xref rid="aff1" ref-type="aff">1</xref>
          <ext-link ext-link-type="orcid">https://orcid.org/0000-0003-1082-7055</ext-link>
        </contrib>
        <contrib id="contrib5" contrib-type="author">
          <name name-style="western">
            <surname>Popham</surname>
            <given-names>Sara</given-names>
          </name>
          <degrees>PhD</degrees>
          <xref rid="aff1" ref-type="aff">1</xref>
          <ext-link ext-link-type="orcid">https://orcid.org/0000-0002-1203-5724</ext-link>
        </contrib>
        <contrib id="contrib6" contrib-type="author">
          <name name-style="western">
            <surname>Kapur</surname>
            <given-names>Ritu</given-names>
          </name>
          <degrees>PhD</degrees>
          <xref rid="aff1" ref-type="aff">1</xref>
          <ext-link ext-link-type="orcid">https://orcid.org/0000-0003-3488-9963</ext-link>
        </contrib>
      </contrib-group>
      <aff id="aff1">
        <label>1</label>
        <institution>Verily Life Sciences</institution>
        <addr-line>South San Francisco, CA</addr-line>
        <country>United States</country>
      </aff>
      <author-notes>
        <corresp>Corresponding Author: Nathan Kowahl <email>natekowahl@verily.com</email></corresp>
      </author-notes>
      <pub-date pub-type="collection">
        <year>2023</year>
      </pub-date>
      <pub-date pub-type="epub">
        <day>3</day>
        <month>8</month>
        <year>2023</year>
      </pub-date>
      <volume>10</volume>
      <elocation-id>e48270</elocation-id>
      <history>
        <date date-type="received">
          <day>21</day>
          <month>4</month>
          <year>2023</year>
        </date>
        <date date-type="rev-request">
          <day>14</day>
          <month>5</month>
          <year>2023</year>
        </date>
        <date date-type="rev-recd">
          <day>22</day>
          <month>5</month>
          <year>2023</year>
        </date>
        <date date-type="accepted">
          <day>21</day>
          <month>6</month>
          <year>2023</year>
        </date>
      </history>
      <copyright-statement>©Nathan Kowahl, Sooyoon Shin, Poulami Barman, Erin Rainaldi, Sara Popham, Ritu Kapur. Originally published in JMIR Human Factors (https://humanfactors.jmir.org), 03.08.2023.</copyright-statement>
      <copyright-year>2023</copyright-year>
      <license license-type="open-access" xlink:href="https://creativecommons.org/licenses/by/4.0/">
        <p>This is an open-access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work, first published in JMIR Human Factors, is properly cited. The complete bibliographic information, a link to the original publication on https://humanfactors.jmir.org, as well as this copyright and license information must be included.</p>
      </license>
      <self-uri xlink:href="https://humanfactors.jmir.org/2023/1/e48270" xlink:type="simple"/>
      <abstract>
        <sec sec-type="background">
          <title>Background</title>
          <p>Mobility is a meaningful aspect of an individual’s health whose quantification can provide clinical insights. Wearable sensor technology can quantify walking behaviors (a key aspect of mobility) through continuous passive monitoring.</p>
        </sec>
        <sec sec-type="objective">
          <title>Objective</title>
          <p>Our objective was to characterize the analytical performance (accuracy and reliability) of a suite of digital measures of walking behaviors as critical aspects in the practical implementation of digital measures into clinical studies.</p>
        </sec>
        <sec sec-type="methods">
          <title>Methods</title>
          <p>We collected data from a wrist-worn device (the Verily Study Watch) worn for multiple days by a cohort of volunteer participants without a history of gait or walking impairment in a real-world setting. On the basis of step measurements computed in 10-second epochs from sensor data, we generated individual daily aggregates (participant-days) to derive a suite of measures of walking: step count, walking bout duration, number of total walking bouts, number of long walking bouts, number of short walking bouts, peak 30-minute walking cadence, and peak 30-minute walking pace. To characterize the accuracy of the measures, we examined agreement with truth labels generated by a concurrent, ankle-worn, reference device (Modus StepWatch 4) with known low error, calculating the following metrics: intraclass correlation coefficient (ICC), Pearson <italic>r</italic> coefficient, mean error, and mean absolute error. To characterize the reliability, we developed a novel approach to identify the time to reach a reliable readout (time to reliability) for each measure. This was accomplished by computing mean values over aggregation scopes ranging from 1 to 30 days and analyzing test-retest reliability based on ICCs between adjacent (nonoverlapping) time windows for each measure.</p>
        </sec>
        <sec sec-type="results">
          <title>Results</title>
          <p>In the accuracy characterization, we collected data for a total of 162 participant-days from a testing cohort (n=35 participants; median observation time 5 days). Agreement with the reference device–based readouts in the testing subcohort (n=35) for the 8 measurements under evaluation, as reflected by ICCs, ranged between 0.7 and 0.9; Pearson <italic>r</italic> values were all greater than 0.75, and all reached statistical significance (<italic>P</italic>&#60;.001). For the time-to-reliability characterization, we collected data for a total of 15,120 participant-days (overall cohort N=234; median observation time 119 days). All digital measures achieved an ICC between adjacent readouts of &#62;0.75 by 16 days of wear time.</p>
        </sec>
        <sec sec-type="conclusions">
          <title>Conclusions</title>
          <p>We characterized the accuracy and reliability of a suite of digital measures that provides comprehensive information about walking behaviors in real-world settings. These results, which report the level of agreement with high-accuracy reference labels and the time duration required to establish reliable measure readouts, can guide the practical implementation of these measures into clinical studies. Well-characterized tools to quantify walking behaviors in research contexts can provide valuable clinical information about general population cohorts and patients with specific conditions.</p>
        </sec>
      </abstract>
      <kwd-group>
        <kwd>digital measurements</kwd>
        <kwd>wearable technology</kwd>
        <kwd>mobility measurements</kwd>
        <kwd>walking patterns</kwd>
        <kwd>wearable</kwd>
        <kwd>wearables</kwd>
        <kwd>sensor</kwd>
        <kwd>sensors</kwd>
        <kwd>mobility</kwd>
        <kwd>measurement</kwd>
        <kwd>measurements</kwd>
        <kwd>walk</kwd>
        <kwd>walking</kwd>
        <kwd>gait</kwd>
        <kwd>step</kwd>
        <kwd>wrist-worn</kwd>
        <kwd>reliability</kwd>
        <kwd>accuracy</kwd>
      </kwd-group>
    </article-meta>
  </front>
  <body>
    <sec sec-type="introduction">
      <title>Introduction</title>
      <p>Assessing an individual’s mobility can provide meaningful insights into their general health status. In clinical settings, mobility is a fundamental factor to define prognosis and care as it is closely associated with a wide array of health outcomes [<xref ref-type="bibr" rid="ref1">1</xref>-<xref ref-type="bibr" rid="ref3">3</xref>]. However, accurate and reliable quantification of mobility in real-world settings remains challenging because self-reported data from instruments such as the International Physical Activity Questionnaire can be biased by limited recall and social desirability [<xref ref-type="bibr" rid="ref4">4</xref>,<xref ref-type="bibr" rid="ref5">5</xref>].</p>
      <p>The interest in quantifying physical activity using wearable devices has recently increased, as these technologies can collect objective individualized data [<xref ref-type="bibr" rid="ref6">6</xref>]. Wearable sensors have been incorporated into clinical studies across different disease states to enable movement analyses and the quantification of discrete physical activities to develop clinically meaningful end points [<xref ref-type="bibr" rid="ref7">7</xref>,<xref ref-type="bibr" rid="ref8">8</xref>].</p>
      <p>Yet, to cement their research utility, two aspects of these digital measurements need to be properly characterized: (1) the accuracy with which a digital measurement reads the parameters of interest [<xref ref-type="bibr" rid="ref9">9</xref>] and (2) the amount of aggregated data needed to reliably capture an individual’s underlying behavioral state, minimizing noise related to natural variability, which usually translates into an aggregation time period for data collection (time to reliability). Although accuracy is always a critical aspect in the characterization of a measure’s performance, time to reliability tends to be ignored, even though it is key for establishing fundamental study design specifications (eg, collection time periods and length of wear time per day), defining baselines, or computing power calculations for the detection of intervention effects or other changes.</p>
      <p>Studies characterizing the performance of digital walking measures often focus on step count. However, the literature around these studies shows considerable heterogeneity across designs and some notable limitations. First, analyses tend to rely on truth labels originated by participants’ self-reports, short-term close monitoring [<xref ref-type="bibr" rid="ref10">10</xref>-<xref ref-type="bibr" rid="ref12">12</xref>], or from reference devices with suboptimal accuracy (mean absolute percentage error &#62;20%) and with the same body placement as the investigational devices, which would bias agreement results [<xref ref-type="bibr" rid="ref13">13</xref>]. Second, these studies are often conducted in artificial laboratory environments, which inherently limit behavior range and are susceptible to subjectivity, assessment bias, and unreliability [<xref ref-type="bibr" rid="ref14">14</xref>-<xref ref-type="bibr" rid="ref16">16</xref>]. Third, reliability characterization for investigational digital measurements is often absent from studies, despite having been acknowledged as an important element for the validation of clinically important research metrics, such as patient-reported outcomes [<xref ref-type="bibr" rid="ref17">17</xref>]. Beyond step counts, there have been studies that have used other digital measures (eg, walking intensity captured by the peak 30-minute cadence) to generate clinical insights but without full characterization of their performance [<xref ref-type="bibr" rid="ref18">18</xref>-<xref ref-type="bibr" rid="ref29">29</xref>].</p>
      <p>In a previous study, we developed an algorithm that accurately classifies ambulatory status from data collected from a wrist-worn device, characterizing its performance across diverse demographic groups in a real-world setting [<xref ref-type="bibr" rid="ref30">30</xref>]. Further, results from a substudy of an interventional randomized phase 2 trial demonstrated that digital measures of physical activity (step count and ambulatory time) could be sensitive to treatment effects in patients with Lewy body dementia [<xref ref-type="bibr" rid="ref31">31</xref>].</p>
      <p>Herein, we report on the development of a series of measures that can capture walking behavior comprehensively, characterizing their analytical performance in accuracy and reliability. These measures included (1) step count, (2) walking bout duration, (3) number of total walking bouts, (4) number of long walking bouts, (5) number of short walking bouts, (6) peak 30-minute walking cadence, and (7) peak 30-minute walking pace. To characterize their accuracy, we compared the measure readouts generated from a study device with highly accurate truth labels from an ankle-worn reference device in healthy volunteers. To characterize their reliability, we developed a novel approach to calculate the aggregated time required to reach a reliable readout (time to reliability) for each measure.</p>
    </sec>
    <sec sec-type="methods">
      <title>Methods</title>
      <sec>
        <title>Study Participants</title>
        <p>The study cohort (pilot program study) included adult volunteer participants, recruited among Verily Life Sciences employees in 2 locations (South San Francisco, CA, and Cambridge, MA), without specific selection criteria. Gender and age information was collected for the accuracy characterization (not for the reliability characterization). This study was determined to be exempt research that did not require institutional review board review.</p>
      </sec>
      <sec>
        <title>Devices</title>
        <p>The Verily Study Watch was the study device. This is a wrist-worn smartwatch that records acceleration data via an onboard inertial measurement unit with a 30 Hz 3-axis accelerometer. The study device also has a photoplethysmography sensor and an additional accelerometer and gyroscope with a 100 to 200 Hz sample rate, which this study did not use.</p>
        <p>For the accuracy characterization, we used the ankle-worn Modus StepWatch 4, a Food and Drug Administration–listed, 200 Hz 3-axis accelerometer device, as a reference to obtain ground truth labels for step counts (and, subsequently, the other derived walking measures); raw acceleration data from this device were not used for this study. This device has shown the greatest accuracy for step counting relative to other wearable devices compared with human counting in real-world and in-lab settings [<xref ref-type="bibr" rid="ref24">24</xref>,<xref ref-type="bibr" rid="ref32">32</xref>].</p>
      </sec>
      <sec>
        <title>Generation of Digital Measurements</title>
        <p>We collected continuous, raw accelerometer sensor data from the study smartwatch, computing step counts for every 10-second, nonoverlapping epoch (for additional information about the algorithm associated with the study device to determine step counts, see <xref ref-type="supplementary-material" rid="app1">Multimedia Appendix 1</xref>), and collected step count outputs from the reference device (generated by the algorithm associated with the StepWatch) also in 10-second epochs. From the 10-second epoch-based step counts, other measures of walking were derived, applying the same computations to the step counts from both devices (summarized in <xref ref-type="table" rid="table1">Table 1</xref>). We report the measure readouts as daily aggregates for individual participants (ie, participant-days).</p>
        <table-wrap position="float" id="table1">
          <label>Table 1</label>
          <caption>
            <p>Summary of walking measure definitions.</p>
          </caption>
          <table width="1000" cellpadding="5" cellspacing="0" border="1" rules="groups" frame="hsides">
            <col width="330"/>
            <col width="670"/>
            <thead>
              <tr valign="top">
                <td>Daily walking measure</td>
                <td>Definition</td>
              </tr>
            </thead>
            <tbody>
              <tr valign="top">
                <td>Step count</td>
                <td>Summed number of steps per day</td>
              </tr>
              <tr valign="top">
                <td>Number of walking bouts<sup>a</sup></td>
                <td>Summed number of walking bouts per participant-day</td>
              </tr>
              <tr valign="top">
                <td>Number of short walking bouts</td>
                <td>Summed number of walking bouts lasting between ≥30 seconds and &#60;1 minute, per participant-day</td>
              </tr>
              <tr valign="top">
                <td>Number of long walking bouts</td>
                <td>Summed number of walking bouts lasting ≥2 minutes per participant-day</td>
              </tr>
              <tr valign="top">
                <td>Walking bout duration, mean</td>
                <td>Mean duration of daily walking bouts</td>
              </tr>
              <tr valign="top">
                <td>Walking bout duration, SD</td>
                <td>SD of the duration of daily walking bouts</td>
              </tr>
              <tr valign="top">
                <td>Walking bout duration, 95th percentile</td>
                <td>Highest bout duration below the top 5% longest bouts</td>
              </tr>
              <tr valign="top">
                <td>Peak 30-minute walking cadence<sup>b</sup></td>
                <td>For each participant-day, average cadence for the 180 ten-second epochs (ie, 30 minutes, not necessarily contiguous) with the highest cadence</td>
              </tr>
              <tr valign="top">
                <td>Peak 30-minute walking pace</td>
                <td>For each participant-day, average pace (calculated from the cadence and estimated stride length based on gender and height) for the 180 ten-second epochs (ie, 30 minutes) with the highest cadence (namely, the daily peak 30-minute cadence); measured as meter/second</td>
              </tr>
            </tbody>
          </table>
          <table-wrap-foot>
            <fn id="table1fn1">
              <p><sup>a</sup>A walking bout was defined as a series of contiguous 10-second epochs containing ≥6 steps each and lasting for ≥30 seconds (ie, at least 3 epochs). Epochs were considered contiguous if they were not interrupted by &#62;20 seconds (ie, by no more than two 10-second epochs).</p>
            </fn>
            <fn id="table1fn2">
              <p><sup>b</sup>Walking cadence was defined as the number of steps per unit of time (in this study, per second—steps/second).</p>
            </fn>
          </table-wrap-foot>
        </table-wrap>
      </sec>
      <sec>
        <title>Analyses</title>
        <sec>
          <title>Accuracy Characterization</title>
          <p>For the characterization of accuracy, the observation period ranged from June 2019 to December 2019. The overall analysis cohort (N=70) was split into 2 equal subcohorts (n=35): training and testing groups (Figure S1 in <xref ref-type="supplementary-material" rid="app1">Multimedia Appendix 1</xref>). Participants were required to wear the 2 devices, the smartwatch and the reference device, throughout waking hours for up to 10 days. Step counts were obtained for both the study and the reference devices, for as long as both devices had been worn simultaneously by each participant, and filtered for days with ≥8 hours of wear time and &#62;100 steps. Each subsequent measure was derived based on step counts from each device (<xref ref-type="table" rid="table1">Table 1</xref>) and compared for agreement. Agreement was examined using the following metrics: Fisher intraclass correlation coefficient (ICC) as the main metric, Pearson <italic>r</italic> coefficient, mean error, and mean absolute error. For each metric, we calculated 95% CIs by bootstrapping with 1000 resampling iterations to account for multiple days (generally 5) from a given participant. Additionally, to further characterize the degree of agreement and bias of each measure, we examined measurements and distributions between devices and Bland-Altman plots with 95% limits of agreement.</p>
        </sec>
        <sec>
          <title>Reliability Characterization</title>
          <p>For time-to-reliability characterization, the observation period was 20 months (April 13, 2018, to December 31, 2019). This analysis was designed to determine the duration of time (from 1 to 30 days) over which each measure needs to be aggregated (the different lengths of time tested were termed “aggregation scopes”) to yield stable values, indicating that it reliably captures an individual’s underlying behavioral state. Data were considered analyzable for this objective when participants had worn the device for at least double the duration of a given aggregation scope (in order to have data for 2 nonoverlapping time windows), starting from a minimum of 2 days (for the shortest aggregation scope of 1 day) to a minimum of 60 days (for the longest aggregation scope of 30 days); in addition, at least 50% of the days in each time window had to have ≥12 hours of daily wear. The number of participants meeting these criteria varied according to the span of the aggregation scopes (N=234 for the 1-day aggregation scope [ie, the smallest aggregation scope had the largest cohort]; n=81 for the 30-day aggregation scope [smallest cohort for the largest aggregation scope]; Figure S1B in <xref ref-type="supplementary-material" rid="app1">Multimedia Appendix 1</xref>).</p>
          <p>In this analysis, we included the same set of measures as for the accuracy characterization, except the 30-minute peak walking pace, because the measure is derived directly from 30-minute peak walking cadence (<xref ref-type="table" rid="table1">Table 1</xref>); therefore, the results of this analysis were expected to be identical between these 2 measures. We calculated Fisher ICCs between adjacent, nonoverlapping windows of time for each aggregation scope (1-30 days). We computed a rolling mean for each daily aggregated measure over the set number of days for each aggregation scope and then computed the ICC between adjacent windows. We repeated this computation by shifting the start date of each window by 1 day and repeated the computation testing aggregation scopes between 1 and 30 days.</p>
        </sec>
      </sec>
    </sec>
    <sec sec-type="results">
      <title>Results</title>
      <sec>
        <title>Accuracy Characterization</title>
        <p>A total of 162 participant-days worth of data were collected from the 35 participants in the test cohort, with each participant contributing 1 to 10 days (median 5 days). The mean daily step count, daily ambulatory time, and wear time per participant-day were 10,075.88 (SD 4321.07) steps, 1.86 (SD 0.78) hours, and 13.73 (SD 3.00) hours, respectively (Figure S2 in <xref ref-type="supplementary-material" rid="app1">Multimedia Appendix 1</xref>).</p>
        <p>For each measure of interest (see the Methods section), the comparison of the values generated from the study device against the reference device showed ICC values ranging between 0.701 and 0.865 (<xref ref-type="table" rid="table2">Table 2</xref>, <xref rid="figure1" ref-type="fig">Figure 1</xref>); the measure “mean duration of daily bouts” produced the lowest ICC value (0.701), and “daily step count” had the highest (0.865). Pearson <italic>r</italic> values were all greater than 0.75, and all values were statistically significant (<italic>P</italic>&#60;.001; <xref ref-type="table" rid="table2">Table 2</xref>). The Bland-Altman analysis (<xref rid="figure2" ref-type="fig">Figure 2</xref>, middle) revealed that measure differences between the study and reference devices were not dependent on the measure value without significant bias. Scatter plots (<xref rid="figure2" ref-type="fig">Figure 2</xref>, left) and distribution (<xref rid="figure2" ref-type="fig">Figure 2</xref>, right) of measures between study and reference devices showed overlap for all 9 measures of walking.</p>
        <table-wrap position="float" id="table2">
          <label>Table 2</label>
          <caption>
            <p>Summary of results from the characterization of accuracy of the measures generated from the study device compared with those collected from the reference device (N=35).</p>
          </caption>
          <table width="1000" cellpadding="5" cellspacing="0" border="1" rules="groups" frame="hsides">
            <col width="360"/>
            <col width="160"/>
            <col width="150"/>
            <col width="170"/>
            <col width="160"/>
            <thead>
              <tr valign="bottom">
                <td>Accuracy metric</td>
                <td>ICC<sup>a</sup> (95% CI)</td>
                <td>Pearson <italic>r</italic> (95% CI)</td>
                <td>ME<sup>b</sup> (95% CI)</td>
                <td>MAE<sup>c</sup> (95% CI)</td>
              </tr>
            </thead>
            <tbody>
              <tr valign="top">
                <td>Daily step count</td>
                <td>0.865 (0.809 to 0.933)</td>
                <td>0.881 (0.832 to 0.941)</td>
                <td>151.450 (–486.869 to 726.201)</td>
                <td>1643.145 (1196.832 to 1996.216)</td>
              </tr>
              <tr valign="top">
                <td>Mean duration of daily bouts</td>
                <td>0.701 (0.529 to 0.876)</td>
                <td>0.784 (0.657 to 0.922)</td>
                <td>14.143 (9.657 to 17.607)</td>
                <td>17.141 (12.985 to 20.371)</td>
              </tr>
              <tr valign="top">
                <td>Daily bout duration, SD</td>
                <td>0.738 (0.525 to 0.918)</td>
                <td>0.813 (0.659 to 0.948)</td>
                <td>27.813 (17.180 to 36.224)</td>
                <td>32.585 (22.038 to 41.081)</td>
              </tr>
              <tr valign="top">
                <td>95th percentile of daily bout duration</td>
                <td>0.715 (0.433 to 0.918)</td>
                <td>0.763 (0.550 to 0.932)</td>
                <td>50.293 (28.720 to 67.285)</td>
                <td>69.620 (49.051 to 85.290)</td>
              </tr>
              <tr valign="top">
                <td>Number of daily bouts</td>
                <td>0.756 (0.620 to 0.838)</td>
                <td>0.757 (0.632 to 0.848)</td>
                <td>–0.611 (–3.740 to 2.840)</td>
                <td>11.846 (9.743 to 13.698)</td>
              </tr>
              <tr valign="top">
                <td>Number of long daily bouts</td>
                <td>0.755 (0.638 to 0.845)</td>
                <td>0.781 (0.671 to 0.861)</td>
                <td>1.438 (0.780 to 2.103)</td>
                <td>2.858 (2.426 to 3.232)</td>
              </tr>
              <tr valign="top">
                <td>Number of short daily bouts</td>
                <td>0.754 (0.621 to 0.811)</td>
                <td>0.768 (0.648 to 0.830)</td>
                <td>–2.747 (–4.553 to –0.736)</td>
                <td>8.401 (7.172 to 9.542)</td>
              </tr>
              <tr valign="top">
                <td>Daily peak 30-minute cadence</td>
                <td>0.734 (0.603 to 0.841)</td>
                <td>0.773 (0.662 to 0.862)</td>
                <td>0.045 (0.013 to 0.076)</td>
                <td>0.100 (0.080 to 0.118)</td>
              </tr>
              <tr valign="top">
                <td>Daily peak 30-minute pace</td>
                <td>0.784 (0.668 to 0.873)</td>
                <td>0.802 (0.710 to 0.877)</td>
                <td>0.030 (0.007 to 0.051)</td>
                <td>0.070 (0.057 to 0.082)</td>
              </tr>
            </tbody>
          </table>
          <table-wrap-foot>
            <fn id="table2fn1">
              <p><sup>a</sup>ICC: intraclass correlation coefficient.</p>
            </fn>
            <fn id="table2fn2">
              <p><sup>b</sup>ME: mean error.</p>
            </fn>
            <fn id="table2fn3">
              <p><sup>c</sup>MAE: mean absolute error.</p>
            </fn>
          </table-wrap-foot>
        </table-wrap>
        <fig id="figure1" position="float">
          <label>Figure 1</label>
          <caption>
            <p>Accuracy characterization: ICC results (and 95% CIs) obtained from the comparison of the digital measurements generated from the study device against those from the reference device. ICC: intraclass correlation coefficient.</p>
          </caption>
          <graphic xlink:href="humanfactors_v10i1e48270_fig1.png" alt-version="no" mimetype="image" position="float" xlink:type="simple"/>
        </fig>
        <fig id="figure2" position="float">
          <label>Figure 2</label>
          <caption>
            <p>Accuracy characterization: detailed results of the comparisons of the digital measures generated from the study device against those from the reference device. Left column: plots of study device readouts (y-axis) versus reference device readouts (x-axis). Middle column: modified Bland-Altman plot showing the difference in mean values between devices (y-axis) versus mean values from the reference device (x-axis). Right column: readout value distributions for both devices in the testing subcohort. (A) Daily step count. (B) Daily walking bout duration, mean. (C) Daily walking bout duration, SD. (D) Daily walking bout duration, 95th percentile. (E) Number of daily walking bouts. (F) Number of daily long walking bouts. (G) Number of daily short walking bouts. (H) Daily peak 30-minute walking cadence. (I) Daily peak 30-minute walking pace. LoA: limits of agreement. See <xref ref-type="supplementary-material" rid="app2">Multimedia Appendix 2</xref> for higher resolution image.</p>
          </caption>
          <graphic xlink:href="humanfactors_v10i1e48270_fig2.png" alt-version="no" mimetype="image" position="float" xlink:type="simple"/>
        </fig>
      </sec>
      <sec>
        <title>Reliability Characterization</title>
        <p>In the cohort of eligible participants who yielded analyzable data (see the Methods section, N=234), individual participant data were collected for up to 596 (median 119) days for a total of 15,120 participant-days (see Figure S1B in <xref ref-type="supplementary-material" rid="app1">Multimedia Appendix 1</xref>). The mean daily step count, daily ambulatory time, and daily wear time per participant-day were 9701.06 (SD 4321.88) steps, 77.42 (SD 39.77) minutes, and 17.36 (SD 4.04) hours, respectively.</p>
        <p>We defined aggregation scopes of increasing duration from 1 day up to 30 days. For each of these scopes, the participant subcohorts that generated data deemed analyzable were of variable size (generally decreasing as the aggregation scope grew, <xref rid="figure3" ref-type="fig">Figure 3</xref>).</p>
        <fig id="figure3" position="float">
          <label>Figure 3</label>
          <caption>
            <p>Time-to-reliability characterization: size of the participant subcohorts with analyzable data across the aggregation scopes tested.</p>
          </caption>
          <graphic xlink:href="humanfactors_v10i1e48270_fig3.png" alt-version="no" mimetype="image" position="float" xlink:type="simple"/>
        </fig>
        <p>Across all the measures of interest in this analysis, the stability of the measure (estimated using ICC between adjacent time windows for readout) increased with longer aggregation scopes. The metrics “number of daily bouts,” “bout duration, SD,” and “number of short bouts” reached an ICC ≥0.75 at the earliest aggregation scope (12 days). Ultimately, all digital measures achieved an ICC ≥0.75 by 16 days, which we defined as the potential time-to-reliability benchmark in the context of this study (<xref rid="figure4" ref-type="fig">Figure 4</xref>). ICCs reached a plateau at values ranging between 0.78 and 0.84, depending on the measure.</p>
        <fig id="figure4" position="float">
          <label>Figure 4</label>
          <caption>
            <p>Time-to-reliability characterization: ICCs between adjacent readout windows according to aggregation scope duration, for the digital measures of interest. The line represents the ICC value plot, gray shading represents 95% CIs, and red annotations indicate the aggregation scope first exceeding an ICC value of 0.75. ICC: intraclass correlation coefficient. See <xref ref-type="supplementary-material" rid="app3">Multimedia Appendix 3</xref> for higher resolution image.</p>
          </caption>
          <graphic xlink:href="humanfactors_v10i1e48270_fig4.png" alt-version="no" mimetype="image" position="float" xlink:type="simple"/>
        </fig>
      </sec>
    </sec>
    <sec sec-type="discussion">
      <title>Discussion</title>
      <p>This report expands upon prior research [<xref ref-type="bibr" rid="ref30">30</xref>,<xref ref-type="bibr" rid="ref31">31</xref>], presenting a comprehensive application of an algorithm that captures step count and other aspects of mobility, such as walking cadence and bouts. We characterized the accuracy and reliability of this comprehensive set of digital walking measures from users wearing a wrist-worn device in real-world environments. We showed that these measures of walking reached reliable readings at around 16 days of wear time, and their levels of agreement with the reference device, measured by ICC, ranged between 0.7 and 0.9, a performance that supports their deployment in clinical trial settings with confidence.</p>
      <p>Mobility and walking behaviors represent meaningful aspects of health, known to be associated with quality of life in general and clinical prognosis in specific settings [<xref ref-type="bibr" rid="ref33">33</xref>-<xref ref-type="bibr" rid="ref35">35</xref>]. Therefore, improved methods to measure mobility and walking behaviors have the potential to improve clinical care and clinical trial efficiency. One of the goals of our research is to build accurate tools to objectively quantify the aspects of walking behavior and extract clinically meaningful information in discrete populations of interest. In prior work, we have developed algorithms whose outputs (measures for step counts and ambulatory time) demonstrated sensitivity to treatment effects in patients with Lewy body dementia [<xref ref-type="bibr" rid="ref31">31</xref>]. We have also characterized the accuracy of an iteration of that algorithm in a cohort of diverse individuals in the real world [<xref ref-type="bibr" rid="ref30">30</xref>].</p>
      <p>To our knowledge, this report is the first to characterize the amount of data required to ensure that a digital measure is reliable in a real-world setting. We developed a novel analytic approach to characterize time to reliability, that is, the time needed for a measure to reach a degree of stability. Time to reliability is an important consideration to inform the design of clinical studies tracking real-world data, as it relates to specific metrics of interest. In this study, the time to reliability overall for all measures was ≤16 days (ICC ≥0.75 between nonadjacent readouts for all measures at day 16, <xref rid="figure4" ref-type="fig">Figure 4</xref>). This study included healthy individuals; in a clinical context, we anticipate that the stability of any given measure over time will be dependent on the type and severity of the disease of interest. It is reasonable to speculate that a mostly healthy cohort may demonstrate more variability and a larger distribution of walking behaviors than a cohort with disease burden, and this necessitates further research.</p>
      <p>Most importantly, the algorithms developed to quantify daily step count and measures related to walking cadence and bouts were found to be accurate (agreement between the readouts from the study device and a highly accurate reference device ranged between ICCs of 0.7 and 0.9 for all measures, <xref ref-type="table" rid="table2">Table 2</xref>). Our study approach captured the measures of walking behavior in a real-world setting, over multiple days, to closely resemble actual use cases.</p>
      <p>Considering the exponential growth of research on wearable sensors and related devices in recent years, it is important to place the capabilities described in this report in that context. In this work, we incorporated several key innovative approaches to address shortcomings present in comparable studies evaluating interdevice agreement. Prior studies have used colocated investigational and reference sensors (eg, 2 wrist-worn devices). But because of the known potential errors associated with body placement when capturing walking-related data [<xref ref-type="bibr" rid="ref36">36</xref>-<xref ref-type="bibr" rid="ref39">39</xref>], colocation could be vulnerable to bias toward overestimating performance. Our approach sought to mitigate that by using a highly accurate but pragmatic and ankle-worn source for ground truth labels. Further, most studies have narrowly focused on step counts [<xref ref-type="bibr" rid="ref10">10</xref>-<xref ref-type="bibr" rid="ref16">16</xref>] for short time periods in controlled laboratory environments (eg, only a single day in real-world settings), or when investigating walking bout and cadence or pace measures, they had a limited scope, with small samples of less than 40 participants [<xref ref-type="bibr" rid="ref40">40</xref>-<xref ref-type="bibr" rid="ref42">42</xref>] and short tests (sessions lasting 1 hour or less) performed in clinic. Our study addresses these existing evidence gaps, presenting a set of digital walking measures that are comprehensive beyond step counts and characterizing their analytic performance (accuracy and reliability) extensively, with data accrued throughout multiday periods and in the course of daily living activities. Moreover, given the research heterogeneity (comparisons of different devices, different ground truth sources, and with different analytic approaches), any direct comparison of study results side by side has to be done with caution, which highlights the need for standardization noted in professional statements in this field [<xref ref-type="bibr" rid="ref6">6</xref>,<xref ref-type="bibr" rid="ref9">9</xref>,<xref ref-type="bibr" rid="ref43">43</xref>,<xref ref-type="bibr" rid="ref44">44</xref>].</p>
      <p>This study had limitations in regard to the participant population and the performance quality thresholds. First, our cohort was limited in size and consisted of generally healthy participants. Future studies may be needed to characterize the generalizability of the performance of these measures in populations with particular kinetic hallmarks (eg, neurological conditions, stroke, and trauma) or with mobility capacity issues (eg, cardiovascular or respiratory conditions). Our approach to determine time to reliability can be applied across studies in any therapeutic area and can guide study design requirements for wear time compliance. One aspect that will require attention is the optimization of actual compliance with hypothetical protocol specifications about wear time because this is a device intended for daily life use (for instance, our reliability analysis filtered participant-day data based on a threshold of 12 hours of daily wear time for 50% of the days over an evaluation period, but we did so retrospectively). Second, although we report on performance parameters, the definition of an acceptable performance (accuracy and reliability) quality threshold remains undefined in the field. We did not prespecify performance categories in this study, but, for instance, prior accuracy studies have categorized agreement ICC values 0.7-0.9 as moderate to good [<xref ref-type="bibr" rid="ref40">40</xref>,<xref ref-type="bibr" rid="ref45">45</xref>], and reliability studies for patient-reported outcomes have considered test-retest ICC &#62;0.5 as acceptable [<xref ref-type="bibr" rid="ref46">46</xref>]. Importantly, what constitutes a clinically meaningful change for each of the measures of walking will likely depend on the therapeutic area under consideration. Further research is also needed to address which of these measures can provide clinically relevant insights in a given population. This set of digital walking measures has the potential to convey comprehensive information beyond flat quantification (via step counts), about aspects such as maximal walking capacity, endurance, or activity patterns during daily living, which may have different relevance or sensitivity to detect status changes depending on the health setting (for instance, cardiopulmonary conditions, oncology, or neurology). Furthermore, the optimization of the clinical utility of these measures may require their aggregation into composite metrics. The potential complexity of this future research brings to the forefront the importance of establishing first a thorough understanding of their individual analytical performance, which this study does. We believe that the accuracy and reliability results detailed here are the first step to support the use of digital measures of walking as feasible and reliable end points in clinical studies.</p>
      <p>In conclusion, we have developed algorithms that accurately quantify daily step counts and measures of walking cadence and bouts from users wearing a wrist-worn device in a real-world setting. Further, we have also developed a novel method for characterizing the time required for a digital measure to stabilize (time to reliability). Given the growing use of wearable sensors to measure aspects of health, these findings may guide practical implementation of these digital measures of walking behavior into clinical studies.</p>
    </sec>
  </body>
  <back>
    <app-group>
      <supplementary-material id="app1">
        <label>Multimedia Appendix 1</label>
        <p>Additional methods and results.</p>
        <media xlink:href="humanfactors_v10i1e48270_app1.docx" xlink:title="DOCX File , 101 KB"/>
      </supplementary-material>
      <supplementary-material id="app2">
        <label>Multimedia Appendix 2</label>
        <p>High resolution version of Figure 2.</p>
        <media xlink:href="humanfactors_v10i1e48270_app2.png" xlink:title="PNG File , 1229 KB"/>
      </supplementary-material>
      <supplementary-material id="app3">
        <label>Multimedia Appendix 3</label>
        <p>High resolution version of Figure 4.</p>
        <media xlink:href="humanfactors_v10i1e48270_app3.png" xlink:title="PNG File , 881 KB"/>
      </supplementary-material>
    </app-group>
    <glossary>
      <title>Abbreviations</title>
      <def-list>
        <def-item>
          <term id="abb1">ICC</term>
          <def>
            <p>intraclass correlation coefficient</p>
          </def>
        </def-item>
      </def-list>
    </glossary>
    <ack>
      <p>The authors wish to acknowledge writing and editing support from Julia Saiz from Verily Life Sciences. This study was sponsored by Verily Life Sciences who was responsible for data collection. The authors had access to the raw study data in full.</p>
    </ack>
    <notes>
      <sec>
        <title>Data Availability</title>
        <p>Data from this study are not available due to the nature of this program. Participants did not consent for their data to be shared publicly.</p>
      </sec>
    </notes>
    <fn-group>
      <fn fn-type="con">
        <p>NK, ER, and RK conceptualized and designed the study. Verily Life Sciences LLC collected the data. NK, SS, PB, and SP analyzed and interpreted the data. All authors interpreted the results, wrote and reviewed the manuscript, and approved the final manuscript for submission.</p>
      </fn>
      <fn fn-type="conflict">
        <p>All authors report employment and equity ownership in Verily Life Sciences.</p>
      </fn>
    </fn-group>
    <ref-list>
      <ref id="ref1">
        <label>1</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Wohlrab</surname>
              <given-names>M</given-names>
            </name>
            <name name-style="western">
              <surname>Klenk</surname>
              <given-names>J</given-names>
            </name>
            <name name-style="western">
              <surname>Delgado-Ortiz</surname>
              <given-names>L</given-names>
            </name>
            <name name-style="western">
              <surname>Chambers</surname>
              <given-names>M</given-names>
            </name>
            <name name-style="western">
              <surname>Rochester</surname>
              <given-names>L</given-names>
            </name>
            <name name-style="western">
              <surname>Zuchowski</surname>
              <given-names>M</given-names>
            </name>
            <name name-style="western">
              <surname>Schwab</surname>
              <given-names>M</given-names>
            </name>
            <name name-style="western">
              <surname>Becker</surname>
              <given-names>C</given-names>
            </name>
            <name name-style="western">
              <surname>Jaeger</surname>
              <given-names>SU</given-names>
            </name>
          </person-group>
          <article-title>The value of walking: a systematic review on mobility and healthcare costs</article-title>
          <source>Eur Rev Aging Phys Act</source>
          <year>2022</year>
          <volume>19</volume>
          <issue>1</issue>
          <fpage>31</fpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://eurapa.biomedcentral.com/articles/10.1186/s11556-022-00310-3"/>
          </comment>
          <pub-id pub-id-type="doi">10.1186/s11556-022-00310-3</pub-id>
          <pub-id pub-id-type="medline">36581809</pub-id>
          <pub-id pub-id-type="pii">10.1186/s11556-022-00310-3</pub-id>
          <pub-id pub-id-type="pmcid">PMC9798720</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref2">
        <label>2</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Piercy</surname>
              <given-names>KL</given-names>
            </name>
            <name name-style="western">
              <surname>Troiano</surname>
              <given-names>RP</given-names>
            </name>
            <name name-style="western">
              <surname>Ballard</surname>
              <given-names>RM</given-names>
            </name>
            <name name-style="western">
              <surname>Carlson</surname>
              <given-names>SA</given-names>
            </name>
            <name name-style="western">
              <surname>Fulton</surname>
              <given-names>JE</given-names>
            </name>
            <name name-style="western">
              <surname>Galuska</surname>
              <given-names>DA</given-names>
            </name>
            <name name-style="western">
              <surname>George</surname>
              <given-names>SM</given-names>
            </name>
            <name name-style="western">
              <surname>Olson</surname>
              <given-names>RD</given-names>
            </name>
          </person-group>
          <article-title>The physical activity guidelines for Americans</article-title>
          <source>JAMA</source>
          <year>2018</year>
          <volume>320</volume>
          <issue>19</issue>
          <fpage>2020</fpage>
          <lpage>2028</lpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://europepmc.org/abstract/MED/30418471"/>
          </comment>
          <pub-id pub-id-type="doi">10.1001/jama.2018.14854</pub-id>
          <pub-id pub-id-type="medline">30418471</pub-id>
          <pub-id pub-id-type="pii">2712935</pub-id>
          <pub-id pub-id-type="pmcid">PMC9582631</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref3">
        <label>3</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Xiang</surname>
              <given-names>X</given-names>
            </name>
            <name name-style="western">
              <surname>Huang</surname>
              <given-names>L</given-names>
            </name>
            <name name-style="western">
              <surname>Fang</surname>
              <given-names>Y</given-names>
            </name>
            <name name-style="western">
              <surname>Cai</surname>
              <given-names>S</given-names>
            </name>
            <name name-style="western">
              <surname>Zhang</surname>
              <given-names>M</given-names>
            </name>
          </person-group>
          <article-title>Physical activity and chronic obstructive pulmonary disease: a scoping review</article-title>
          <source>BMC Pulm Med</source>
          <year>2022</year>
          <volume>22</volume>
          <issue>1</issue>
          <fpage>301</fpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://bmcpulmmed.biomedcentral.com/articles/10.1186/s12890-022-02099-4"/>
          </comment>
          <pub-id pub-id-type="doi">10.1186/s12890-022-02099-4</pub-id>
          <pub-id pub-id-type="medline">35932050</pub-id>
          <pub-id pub-id-type="pii">10.1186/s12890-022-02099-4</pub-id>
          <pub-id pub-id-type="pmcid">PMC9354440</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref4">
        <label>4</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Skender</surname>
              <given-names>S</given-names>
            </name>
            <name name-style="western">
              <surname>Ose</surname>
              <given-names>J</given-names>
            </name>
            <name name-style="western">
              <surname>Chang-Claude</surname>
              <given-names>J</given-names>
            </name>
            <name name-style="western">
              <surname>Paskow</surname>
              <given-names>M</given-names>
            </name>
            <name name-style="western">
              <surname>Brühmann</surname>
              <given-names>B</given-names>
            </name>
            <name name-style="western">
              <surname>Siegel</surname>
              <given-names>EM</given-names>
            </name>
            <name name-style="western">
              <surname>Steindorf</surname>
              <given-names>K</given-names>
            </name>
            <name name-style="western">
              <surname>Ulrich</surname>
              <given-names>CM</given-names>
            </name>
          </person-group>
          <article-title>Accelerometry and physical activity questionnaires—a systematic review</article-title>
          <source>BMC Public Health</source>
          <year>2016</year>
          <volume>16</volume>
          <fpage>515</fpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://bmcpublichealth.biomedcentral.com/articles/10.1186/s12889-016-3172-0"/>
          </comment>
          <pub-id pub-id-type="doi">10.1186/s12889-016-3172-0</pub-id>
          <pub-id pub-id-type="medline">27306667</pub-id>
          <pub-id pub-id-type="pii">10.1186/s12889-016-3172-0</pub-id>
          <pub-id pub-id-type="pmcid">PMC4910242</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref5">
        <label>5</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Fiedler</surname>
              <given-names>J</given-names>
            </name>
            <name name-style="western">
              <surname>Eckert</surname>
              <given-names>T</given-names>
            </name>
            <name name-style="western">
              <surname>Burchartz</surname>
              <given-names>A</given-names>
            </name>
            <name name-style="western">
              <surname>Woll</surname>
              <given-names>A</given-names>
            </name>
            <name name-style="western">
              <surname>Wunsch</surname>
              <given-names>K</given-names>
            </name>
          </person-group>
          <article-title>Comparison of self-reported and device-based measured physical activity using measures of stability, reliability, and validity in adults and children</article-title>
          <source>Sensors (Basel)</source>
          <year>2021</year>
          <volume>21</volume>
          <issue>8</issue>
          <fpage>2672</fpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://www.mdpi.com/1424-8220/21/8/2672"/>
          </comment>
          <pub-id pub-id-type="doi">10.3390/s21082672</pub-id>
          <pub-id pub-id-type="medline">33920145</pub-id>
          <pub-id pub-id-type="pii">s21082672</pub-id>
          <pub-id pub-id-type="pmcid">PMC8069485</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref6">
        <label>6</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Düking</surname>
              <given-names>P</given-names>
            </name>
            <name name-style="western">
              <surname>Fuss</surname>
              <given-names>FK</given-names>
            </name>
            <name name-style="western">
              <surname>Holmberg</surname>
              <given-names>HC</given-names>
            </name>
            <name name-style="western">
              <surname>Sperlich</surname>
              <given-names>B</given-names>
            </name>
          </person-group>
          <article-title>Recommendations for assessment of the reliability, sensitivity, and validity of data provided by wearable sensors designed for monitoring physical activity</article-title>
          <source>JMIR Mhealth Uhealth</source>
          <year>2018</year>
          <volume>6</volume>
          <issue>4</issue>
          <fpage>e102</fpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://mhealth.jmir.org/2018/4/e102/"/>
          </comment>
          <pub-id pub-id-type="doi">10.2196/mhealth.9341</pub-id>
          <pub-id pub-id-type="medline">29712629</pub-id>
          <pub-id pub-id-type="pii">v6i4e102</pub-id>
          <pub-id pub-id-type="pmcid">PMC5952119</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref7">
        <label>7</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Palmerini</surname>
              <given-names>L</given-names>
            </name>
            <name name-style="western">
              <surname>Reggi</surname>
              <given-names>L</given-names>
            </name>
            <name name-style="western">
              <surname>Bonci</surname>
              <given-names>T</given-names>
            </name>
            <name name-style="western">
              <surname>Del Din</surname>
              <given-names>S</given-names>
            </name>
            <name name-style="western">
              <surname>Micó-Amigo</surname>
              <given-names>ME</given-names>
            </name>
            <name name-style="western">
              <surname>Salis</surname>
              <given-names>F</given-names>
            </name>
            <name name-style="western">
              <surname>Bertuletti</surname>
              <given-names>S</given-names>
            </name>
            <name name-style="western">
              <surname>Caruso</surname>
              <given-names>M</given-names>
            </name>
            <name name-style="western">
              <surname>Cereatti</surname>
              <given-names>A</given-names>
            </name>
            <name name-style="western">
              <surname>Gazit</surname>
              <given-names>E</given-names>
            </name>
            <name name-style="western">
              <surname>Paraschiv-Ionescu</surname>
              <given-names>A</given-names>
            </name>
            <name name-style="western">
              <surname>Soltani</surname>
              <given-names>A</given-names>
            </name>
            <name name-style="western">
              <surname>Kluge</surname>
              <given-names>F</given-names>
            </name>
            <name name-style="western">
              <surname>Küderle</surname>
              <given-names>A</given-names>
            </name>
            <name name-style="western">
              <surname>Ullrich</surname>
              <given-names>M</given-names>
            </name>
            <name name-style="western">
              <surname>Kirk</surname>
              <given-names>C</given-names>
            </name>
            <name name-style="western">
              <surname>Hiden</surname>
              <given-names>H</given-names>
            </name>
            <name name-style="western">
              <surname>D'Ascanio</surname>
              <given-names>I</given-names>
            </name>
            <name name-style="western">
              <surname>Hansen</surname>
              <given-names>C</given-names>
            </name>
            <name name-style="western">
              <surname>Rochester</surname>
              <given-names>L</given-names>
            </name>
            <name name-style="western">
              <surname>Mazzà</surname>
              <given-names>C</given-names>
            </name>
            <name name-style="western">
              <surname>Chiari</surname>
              <given-names>L</given-names>
            </name>
          </person-group>
          <article-title>Mobility recorded by wearable devices and gold standards: the mobilise-D procedure for data standardization</article-title>
          <source>Sci Data</source>
          <year>2023</year>
          <volume>10</volume>
          <issue>1</issue>
          <fpage>38</fpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://www.nature.com/articles/s41597-023-01930-9"/>
          </comment>
          <pub-id pub-id-type="doi">10.1038/s41597-023-01930-9</pub-id>
          <pub-id pub-id-type="medline">36658136</pub-id>
          <pub-id pub-id-type="pii">10.1038/s41597-023-01930-9</pub-id>
          <pub-id pub-id-type="pmcid">PMC9852581</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref8">
        <label>8</label>
        <nlm-citation citation-type="web">
          <article-title>Library of digital endpoints</article-title>
          <source>Digital Medicine Society (DiMe)</source>
          <access-date>2023-06-27</access-date>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://dimesociety.org/communication-education/library-of-digital-endpoints/">https://dimesociety.org/communication-education/library-of-digital-endpoints/</ext-link>
          </comment>
        </nlm-citation>
      </ref>
      <ref id="ref9">
        <label>9</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Goldsack</surname>
              <given-names>JC</given-names>
            </name>
            <name name-style="western">
              <surname>Coravos</surname>
              <given-names>A</given-names>
            </name>
            <name name-style="western">
              <surname>Bakker</surname>
              <given-names>JP</given-names>
            </name>
            <name name-style="western">
              <surname>Bent</surname>
              <given-names>B</given-names>
            </name>
            <name name-style="western">
              <surname>Dowling</surname>
              <given-names>AV</given-names>
            </name>
            <name name-style="western">
              <surname>Fitzer-Attas</surname>
              <given-names>C</given-names>
            </name>
            <name name-style="western">
              <surname>Godfrey</surname>
              <given-names>A</given-names>
            </name>
            <name name-style="western">
              <surname>Godino</surname>
              <given-names>JG</given-names>
            </name>
            <name name-style="western">
              <surname>Gujar</surname>
              <given-names>N</given-names>
            </name>
            <name name-style="western">
              <surname>Izmailova</surname>
              <given-names>E</given-names>
            </name>
            <name name-style="western">
              <surname>Manta</surname>
              <given-names>C</given-names>
            </name>
            <name name-style="western">
              <surname>Peterson</surname>
              <given-names>B</given-names>
            </name>
            <name name-style="western">
              <surname>Vandendriessche</surname>
              <given-names>B</given-names>
            </name>
            <name name-style="western">
              <surname>Wood</surname>
              <given-names>WA</given-names>
            </name>
            <name name-style="western">
              <surname>Wang</surname>
              <given-names>KW</given-names>
            </name>
            <name name-style="western">
              <surname>Dunn</surname>
              <given-names>J</given-names>
            </name>
          </person-group>
          <article-title>Verification, analytical validation, and clinical validation (V3): the foundation of determining fit-for-purpose for Biometric Monitoring Technologies (BioMeTs)</article-title>
          <source>NPJ Digit Med</source>
          <year>2020</year>
          <volume>3</volume>
          <fpage>55</fpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://www.nature.com/articles/s41746-020-0260-4"/>
          </comment>
          <pub-id pub-id-type="doi">10.1038/s41746-020-0260-4</pub-id>
          <pub-id pub-id-type="medline">32337371</pub-id>
          <pub-id pub-id-type="pii">260</pub-id>
          <pub-id pub-id-type="pmcid">PMC7156507</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref10">
        <label>10</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Veerubhotla</surname>
              <given-names>A</given-names>
            </name>
            <name name-style="western">
              <surname>Krantz</surname>
              <given-names>A</given-names>
            </name>
            <name name-style="western">
              <surname>Ibironke</surname>
              <given-names>O</given-names>
            </name>
            <name name-style="western">
              <surname>Pilkar</surname>
              <given-names>R</given-names>
            </name>
          </person-group>
          <article-title>Wearable devices for tracking physical activity in the community after an acquired brain injury: a systematic review</article-title>
          <source>PM R</source>
          <year>2022</year>
          <volume>14</volume>
          <issue>10</issue>
          <fpage>1207</fpage>
          <lpage>1218</lpage>
          <pub-id pub-id-type="doi">10.1002/pmrj.12725</pub-id>
          <pub-id pub-id-type="medline">34689426</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref11">
        <label>11</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Mora-Gonzalez</surname>
              <given-names>J</given-names>
            </name>
            <name name-style="western">
              <surname>Gould</surname>
              <given-names>ZR</given-names>
            </name>
            <name name-style="western">
              <surname>Moore</surname>
              <given-names>CC</given-names>
            </name>
            <name name-style="western">
              <surname>Aguiar</surname>
              <given-names>EJ</given-names>
            </name>
            <name name-style="western">
              <surname>Ducharme</surname>
              <given-names>SW</given-names>
            </name>
            <name name-style="western">
              <surname>Schuna</surname>
              <given-names>JM</given-names>
            </name>
            <name name-style="western">
              <surname>Barreira</surname>
              <given-names>TV</given-names>
            </name>
            <name name-style="western">
              <surname>Staudenmayer</surname>
              <given-names>J</given-names>
            </name>
            <name name-style="western">
              <surname>McAvoy</surname>
              <given-names>CR</given-names>
            </name>
            <name name-style="western">
              <surname>Boikova</surname>
              <given-names>M</given-names>
            </name>
            <name name-style="western">
              <surname>Miller</surname>
              <given-names>TA</given-names>
            </name>
            <name name-style="western">
              <surname>Tudor-Locke</surname>
              <given-names>C</given-names>
            </name>
          </person-group>
          <article-title>A catalog of validity indices for step counting wearable technologies during treadmill walking: the CADENCE-adults study</article-title>
          <source>Int J Behav Nutr Phys Act</source>
          <year>2022</year>
          <volume>19</volume>
          <issue>1</issue>
          <fpage>117</fpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://ijbnpa.biomedcentral.com/articles/10.1186/s12966-022-01350-9"/>
          </comment>
          <pub-id pub-id-type="doi">10.1186/s12966-022-01350-9</pub-id>
          <pub-id pub-id-type="medline">36076265</pub-id>
          <pub-id pub-id-type="pii">10.1186/s12966-022-01350-9</pub-id>
          <pub-id pub-id-type="pmcid">PMC9461139</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref12">
        <label>12</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Wu</surname>
              <given-names>Y</given-names>
            </name>
            <name name-style="western">
              <surname>Petterson</surname>
              <given-names>JL</given-names>
            </name>
            <name name-style="western">
              <surname>Bray</surname>
              <given-names>NW</given-names>
            </name>
            <name name-style="western">
              <surname>Kimmerly</surname>
              <given-names>DS</given-names>
            </name>
            <name name-style="western">
              <surname>O'Brien</surname>
              <given-names>MW</given-names>
            </name>
          </person-group>
          <article-title>Validity of the activPAL monitor to measure stepping activity and activity intensity: a systematic review</article-title>
          <source>Gait Posture</source>
          <year>2022</year>
          <volume>97</volume>
          <fpage>165</fpage>
          <lpage>173</lpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://www.sciencedirect.com/science/article/abs/pii/S0966636222004672?via%3Dihub"/>
          </comment>
          <pub-id pub-id-type="doi">10.1016/j.gaitpost.2022.08.002</pub-id>
          <pub-id pub-id-type="medline">35964334</pub-id>
          <pub-id pub-id-type="pii">S0966-6362(22)00467-2</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref13">
        <label>13</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Ducharme</surname>
              <given-names>SW</given-names>
            </name>
            <name name-style="western">
              <surname>Lim</surname>
              <given-names>J</given-names>
            </name>
            <name name-style="western">
              <surname>Busa</surname>
              <given-names>MA</given-names>
            </name>
            <name name-style="western">
              <surname>Aguiar</surname>
              <given-names>EJ</given-names>
            </name>
            <name name-style="western">
              <surname>Moore</surname>
              <given-names>CC</given-names>
            </name>
            <name name-style="western">
              <surname>Schuna</surname>
              <given-names>JM</given-names>
            </name>
            <name name-style="western">
              <surname>Barreira</surname>
              <given-names>TV</given-names>
            </name>
            <name name-style="western">
              <surname>Staudenmayer</surname>
              <given-names>J</given-names>
            </name>
            <name name-style="western">
              <surname>Chipkin</surname>
              <given-names>SR</given-names>
            </name>
            <name name-style="western">
              <surname>Tudor-Locke</surname>
              <given-names>C</given-names>
            </name>
          </person-group>
          <article-title>A transparent method for step detection using an acceleration threshold</article-title>
          <source>J Meas Phys Behav</source>
          <year>2021</year>
          <volume>4</volume>
          <issue>4</issue>
          <fpage>311</fpage>
          <lpage>320</lpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://europepmc.org/abstract/MED/36274923"/>
          </comment>
          <pub-id pub-id-type="doi">10.1123/jmpb.2021-0011</pub-id>
          <pub-id pub-id-type="medline">36274923</pub-id>
          <pub-id pub-id-type="pmcid">PMC9586317</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref14">
        <label>14</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Stenbäck</surname>
              <given-names>V</given-names>
            </name>
            <name name-style="western">
              <surname>Leppäluoto</surname>
              <given-names>J</given-names>
            </name>
            <name name-style="western">
              <surname>Leskelä</surname>
              <given-names>N</given-names>
            </name>
            <name name-style="western">
              <surname>Viitala</surname>
              <given-names>L</given-names>
            </name>
            <name name-style="western">
              <surname>Vihriälä</surname>
              <given-names>E</given-names>
            </name>
            <name name-style="western">
              <surname>Gagnon</surname>
              <given-names>D</given-names>
            </name>
            <name name-style="western">
              <surname>Tulppo</surname>
              <given-names>M</given-names>
            </name>
            <name name-style="western">
              <surname>Herzig</surname>
              <given-names>KH</given-names>
            </name>
          </person-group>
          <article-title>Step detection and energy expenditure at different speeds by three accelerometers in a controlled environment</article-title>
          <source>Sci Rep</source>
          <year>2021</year>
          <volume>11</volume>
          <issue>1</issue>
          <fpage>20005</fpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://www.nature.com/articles/s41598-021-97299-z"/>
          </comment>
          <pub-id pub-id-type="doi">10.1038/s41598-021-97299-z</pub-id>
          <pub-id pub-id-type="medline">34625578</pub-id>
          <pub-id pub-id-type="pii">10.1038/s41598-021-97299-z</pub-id>
          <pub-id pub-id-type="pmcid">PMC8501125</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref15">
        <label>15</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Sjöberg</surname>
              <given-names>V</given-names>
            </name>
            <name name-style="western">
              <surname>Westergren</surname>
              <given-names>J</given-names>
            </name>
            <name name-style="western">
              <surname>Monnier</surname>
              <given-names>A</given-names>
            </name>
            <name name-style="western">
              <surname>Lo Martire</surname>
              <given-names>R</given-names>
            </name>
            <name name-style="western">
              <surname>Hagströmer</surname>
              <given-names>M</given-names>
            </name>
            <name name-style="western">
              <surname>Äng</surname>
              <given-names>BO</given-names>
            </name>
            <name name-style="western">
              <surname>Vixner</surname>
              <given-names>L</given-names>
            </name>
          </person-group>
          <article-title>Wrist-worn activity trackers in laboratory and free-living settings for patients with chronic pain: criterion validity study</article-title>
          <source>JMIR Mhealth Uhealth</source>
          <year>2021</year>
          <volume>9</volume>
          <issue>1</issue>
          <fpage>e24806</fpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://mhealth.jmir.org/2021/1/e24806/"/>
          </comment>
          <pub-id pub-id-type="doi">10.2196/24806</pub-id>
          <pub-id pub-id-type="medline">33433391</pub-id>
          <pub-id pub-id-type="pii">v9i1e24806</pub-id>
          <pub-id pub-id-type="pmcid">PMC7838001</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref16">
        <label>16</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Gould</surname>
              <given-names>ZR</given-names>
            </name>
            <name name-style="western">
              <surname>Mora-Gonzalez</surname>
              <given-names>J</given-names>
            </name>
            <name name-style="western">
              <surname>Aguiar</surname>
              <given-names>EJ</given-names>
            </name>
            <name name-style="western">
              <surname>Schuna</surname>
              <given-names>JM</given-names>
            </name>
            <name name-style="western">
              <surname>Barreira</surname>
              <given-names>TV</given-names>
            </name>
            <name name-style="western">
              <surname>Moore</surname>
              <given-names>CC</given-names>
            </name>
            <name name-style="western">
              <surname>Staudenmayer</surname>
              <given-names>J</given-names>
            </name>
            <name name-style="western">
              <surname>Tudor-Locke</surname>
              <given-names>C</given-names>
            </name>
          </person-group>
          <article-title>A catalog of validity indices for step counting wearable technologies during treadmill walking: the CADENCE-Kids study</article-title>
          <source>Int J Behav Nutr Phys Act</source>
          <year>2021</year>
          <volume>18</volume>
          <issue>1</issue>
          <fpage>97</fpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://ijbnpa.biomedcentral.com/articles/10.1186/s12966-021-01167-y"/>
          </comment>
          <pub-id pub-id-type="doi">10.1186/s12966-021-01167-y</pub-id>
          <pub-id pub-id-type="medline">34271922</pub-id>
          <pub-id pub-id-type="pii">10.1186/s12966-021-01167-y</pub-id>
          <pub-id pub-id-type="pmcid">PMC8283935</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref17">
        <label>17</label>
        <nlm-citation citation-type="web">
          <person-group person-group-type="author">
            <collab>U.S. Department of Health and Human Services, Food and Drug Administration</collab>
          </person-group>
          <article-title>Guidance for industry</article-title>
          <source>Patient-reported outcome measures: use in medical product development to support labeling claims</source>
          <year>2009</year>
          <access-date>2023-06-27</access-date>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://www.fda.gov/media/77832/download">https://www.fda.gov/media/77832/download</ext-link>
          </comment>
        </nlm-citation>
      </ref>
      <ref id="ref18">
        <label>18</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Del Pozo Cruz</surname>
              <given-names>B</given-names>
            </name>
            <name name-style="western">
              <surname>Ahmadi</surname>
              <given-names>MN</given-names>
            </name>
            <name name-style="western">
              <surname>Lee</surname>
              <given-names>IM</given-names>
            </name>
            <name name-style="western">
              <surname>Stamatakis</surname>
              <given-names>E</given-names>
            </name>
          </person-group>
          <article-title>Prospective associations of daily step counts and intensity with cancer and cardiovascular disease incidence and mortality and all-cause mortality</article-title>
          <source>JAMA Intern Med</source>
          <year>2022</year>
          <volume>182</volume>
          <issue>11</issue>
          <fpage>1139</fpage>
          <lpage>1148</lpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://jamanetwork.com/journals/jamainternalmedicine/fullarticle/2796058"/>
          </comment>
          <pub-id pub-id-type="doi">10.1001/jamainternmed.2022.4000</pub-id>
          <pub-id pub-id-type="medline">36094529</pub-id>
          <pub-id pub-id-type="pii">2796058</pub-id>
          <pub-id pub-id-type="pmcid">PMC9468953</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref19">
        <label>19</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Del Pozo Cruz</surname>
              <given-names>B</given-names>
            </name>
            <name name-style="western">
              <surname>Ahmadi</surname>
              <given-names>M</given-names>
            </name>
            <name name-style="western">
              <surname>Naismith</surname>
              <given-names>SL</given-names>
            </name>
            <name name-style="western">
              <surname>Stamatakis</surname>
              <given-names>E</given-names>
            </name>
          </person-group>
          <article-title>Association of daily step count and intensity with incident dementia in 78 430 adults living in the UK</article-title>
          <source>JAMA Neurol</source>
          <year>2022</year>
          <volume>79</volume>
          <issue>10</issue>
          <fpage>1059</fpage>
          <lpage>1063</lpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://jamanetwork.com/journals/jamaneurology/fullarticle/2795819"/>
          </comment>
          <pub-id pub-id-type="doi">10.1001/jamaneurol.2022.2672</pub-id>
          <pub-id pub-id-type="medline">36066874</pub-id>
          <pub-id pub-id-type="pii">2795819</pub-id>
          <pub-id pub-id-type="pmcid">PMC9449869</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref20">
        <label>20</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Neven</surname>
              <given-names>A</given-names>
            </name>
            <name name-style="western">
              <surname>Vanderstraeten</surname>
              <given-names>A</given-names>
            </name>
            <name name-style="western">
              <surname>Janssens</surname>
              <given-names>D</given-names>
            </name>
            <name name-style="western">
              <surname>Wets</surname>
              <given-names>G</given-names>
            </name>
            <name name-style="western">
              <surname>Feys</surname>
              <given-names>P</given-names>
            </name>
          </person-group>
          <article-title>Understanding walking activity in multiple sclerosis: step count, walking intensity and uninterrupted walking activity duration related to degree of disability</article-title>
          <source>Neurol Sci</source>
          <year>2016</year>
          <volume>37</volume>
          <issue>9</issue>
          <fpage>1483</fpage>
          <lpage>1490</lpage>
          <pub-id pub-id-type="doi">10.1007/s10072-016-2609-7</pub-id>
          <pub-id pub-id-type="medline">27207680</pub-id>
          <pub-id pub-id-type="pii">10.1007/s10072-016-2609-7</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref21">
        <label>21</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Aguiar</surname>
              <given-names>EJ</given-names>
            </name>
            <name name-style="western">
              <surname>Schuna</surname>
              <given-names>JM</given-names>
            </name>
            <name name-style="western">
              <surname>Barreira</surname>
              <given-names>TV</given-names>
            </name>
            <name name-style="western">
              <surname>Mire</surname>
              <given-names>EF</given-names>
            </name>
            <name name-style="western">
              <surname>Broyles</surname>
              <given-names>ST</given-names>
            </name>
            <name name-style="western">
              <surname>Katzmarzyk</surname>
              <given-names>PT</given-names>
            </name>
            <name name-style="western">
              <surname>Johnson</surname>
              <given-names>WD</given-names>
            </name>
            <name name-style="western">
              <surname>Tudor-Locke</surname>
              <given-names>C</given-names>
            </name>
          </person-group>
          <article-title>Normative peak 30-min cadence (steps per minute) values for older adults: NHANES 2005-2006</article-title>
          <source>J Aging Phys Act</source>
          <year>2019</year>
          <volume>27</volume>
          <issue>5</issue>
          <fpage>625</fpage>
          <lpage>632</lpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://europepmc.org/abstract/MED/30676186"/>
          </comment>
          <pub-id pub-id-type="doi">10.1123/japa.2018-0316</pub-id>
          <pub-id pub-id-type="medline">30676186</pub-id>
          <pub-id pub-id-type="pmcid">PMC6763372</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref22">
        <label>22</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Guo</surname>
              <given-names>CC</given-names>
            </name>
            <name name-style="western">
              <surname>Chiesa</surname>
              <given-names>PA</given-names>
            </name>
            <name name-style="western">
              <surname>de Moor</surname>
              <given-names>C</given-names>
            </name>
            <name name-style="western">
              <surname>Fazeli</surname>
              <given-names>MS</given-names>
            </name>
            <name name-style="western">
              <surname>Schofield</surname>
              <given-names>T</given-names>
            </name>
            <name name-style="western">
              <surname>Hofer</surname>
              <given-names>K</given-names>
            </name>
            <name name-style="western">
              <surname>Belachew</surname>
              <given-names>S</given-names>
            </name>
            <name name-style="western">
              <surname>Scotland</surname>
              <given-names>A</given-names>
            </name>
          </person-group>
          <article-title>Digital devices for assessing motor functions in mobility-impaired and healthy populations: systematic literature review</article-title>
          <source>J Med Internet Res</source>
          <year>2022</year>
          <volume>24</volume>
          <issue>11</issue>
          <fpage>e37683</fpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://www.jmir.org/2022/11/e37683"/>
          </comment>
          <pub-id pub-id-type="doi">10.2196/37683</pub-id>
          <pub-id pub-id-type="medline">36409538</pub-id>
          <pub-id pub-id-type="pii">v24i11e37683</pub-id>
          <pub-id pub-id-type="pmcid">PMC9723979</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref23">
        <label>23</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Park</surname>
              <given-names>S</given-names>
            </name>
            <name name-style="western">
              <surname>Marcotte</surname>
              <given-names>RT</given-names>
            </name>
            <name name-style="western">
              <surname>Toth</surname>
              <given-names>LP</given-names>
            </name>
            <name name-style="western">
              <surname>Paulus</surname>
              <given-names>P</given-names>
            </name>
            <name name-style="western">
              <surname>Lauricella</surname>
              <given-names>LP</given-names>
            </name>
            <name name-style="western">
              <surname>Kim</surname>
              <given-names>AH</given-names>
            </name>
            <name name-style="western">
              <surname>Crouter</surname>
              <given-names>SE</given-names>
            </name>
            <name name-style="western">
              <surname>Springer</surname>
              <given-names>CM</given-names>
            </name>
            <name name-style="western">
              <surname>Staudenmayer</surname>
              <given-names>JW</given-names>
            </name>
            <name name-style="western">
              <surname>Bassett</surname>
              <given-names>DR</given-names>
            </name>
          </person-group>
          <article-title>Free-living validation and harmonization of 10 wearable step count monitors</article-title>
          <source>Transl J ACSM</source>
          <year>2021</year>
          <volume>6</volume>
          <issue>4</issue>
          <fpage>e000172</fpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://journals.lww.com/acsm-tj/Fulltext/2021/10150/Free_Living_Validation_and_Harmonization_of_10.5.aspx"/>
          </comment>
          <pub-id pub-id-type="doi">10.1249/tjx.0000000000000172</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref24">
        <label>24</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Toth</surname>
              <given-names>LP</given-names>
            </name>
            <name name-style="western">
              <surname>Park</surname>
              <given-names>S</given-names>
            </name>
            <name name-style="western">
              <surname>Springer</surname>
              <given-names>CM</given-names>
            </name>
            <name name-style="western">
              <surname>Feyerabend</surname>
              <given-names>MD</given-names>
            </name>
            <name name-style="western">
              <surname>Steeves</surname>
              <given-names>JA</given-names>
            </name>
            <name name-style="western">
              <surname>Bassett</surname>
              <given-names>DR</given-names>
            </name>
          </person-group>
          <article-title>Video-recorded validation of wearable step counters under free-living conditions</article-title>
          <source>Med Sci Sports Exerc</source>
          <year>2018</year>
          <volume>50</volume>
          <issue>6</issue>
          <fpage>1315</fpage>
          <lpage>1322</lpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://journals.lww.com/acsm-msse/Fulltext/2018/06000/Video_Recorded_Validation_of_Wearable_Step.24.aspx"/>
          </comment>
          <pub-id pub-id-type="doi">10.1249/MSS.0000000000001569</pub-id>
          <pub-id pub-id-type="medline">29381649</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref25">
        <label>25</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Bai</surname>
              <given-names>Y</given-names>
            </name>
            <name name-style="western">
              <surname>Tompkins</surname>
              <given-names>C</given-names>
            </name>
            <name name-style="western">
              <surname>Gell</surname>
              <given-names>N</given-names>
            </name>
            <name name-style="western">
              <surname>Dione</surname>
              <given-names>D</given-names>
            </name>
            <name name-style="western">
              <surname>Zhang</surname>
              <given-names>T</given-names>
            </name>
            <name name-style="western">
              <surname>Byun</surname>
              <given-names>W</given-names>
            </name>
          </person-group>
          <article-title>Comprehensive comparison of Apple Watch and Fitbit Monitors in a free-living setting</article-title>
          <source>PLoS One</source>
          <year>2021</year>
          <volume>16</volume>
          <issue>5</issue>
          <fpage>e0251975</fpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0251975"/>
          </comment>
          <pub-id pub-id-type="doi">10.1371/journal.pone.0251975</pub-id>
          <pub-id pub-id-type="medline">34038458</pub-id>
          <pub-id pub-id-type="pii">PONE-D-20-09081</pub-id>
          <pub-id pub-id-type="pmcid">PMC8153432</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref26">
        <label>26</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Schwenk</surname>
              <given-names>M</given-names>
            </name>
            <name name-style="western">
              <surname>Mohler</surname>
              <given-names>J</given-names>
            </name>
            <name name-style="western">
              <surname>Wendel</surname>
              <given-names>C</given-names>
            </name>
            <name name-style="western">
              <surname>D'Huyvetter</surname>
              <given-names>K</given-names>
            </name>
            <name name-style="western">
              <surname>Fain</surname>
              <given-names>M</given-names>
            </name>
            <name name-style="western">
              <surname>Taylor-Piliae</surname>
              <given-names>R</given-names>
            </name>
            <name name-style="western">
              <surname>Najafi</surname>
              <given-names>B</given-names>
            </name>
          </person-group>
          <article-title>Wearable sensor-based in-home assessment of gait, balance, and physical activity for discrimination of frailty status: baseline results of the Arizona frailty cohort study</article-title>
          <source>Gerontol</source>
          <year>2015</year>
          <volume>61</volume>
          <issue>3</issue>
          <fpage>258</fpage>
          <lpage>267</lpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://karger.com/ger/article/61/3/258/147946/Wearable-Sensor-Based-In-Home-Assessment-of-Gait"/>
          </comment>
          <pub-id pub-id-type="doi">10.1159/000369095</pub-id>
          <pub-id pub-id-type="medline">25547185</pub-id>
          <pub-id pub-id-type="pii">000369095</pub-id>
          <pub-id pub-id-type="pmcid">PMC4452118</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref27">
        <label>27</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Saint-Maurice</surname>
              <given-names>PF</given-names>
            </name>
            <name name-style="western">
              <surname>Troiano</surname>
              <given-names>RP</given-names>
            </name>
            <name name-style="western">
              <surname>Bassett</surname>
              <given-names>DR</given-names>
            </name>
            <name name-style="western">
              <surname>Graubard</surname>
              <given-names>BI</given-names>
            </name>
            <name name-style="western">
              <surname>Carlson</surname>
              <given-names>SA</given-names>
            </name>
            <name name-style="western">
              <surname>Shiroma</surname>
              <given-names>EJ</given-names>
            </name>
            <name name-style="western">
              <surname>Fulton</surname>
              <given-names>JE</given-names>
            </name>
            <name name-style="western">
              <surname>Matthews</surname>
              <given-names>CE</given-names>
            </name>
          </person-group>
          <article-title>Association of daily step count and step intensity with mortality among US adults</article-title>
          <source>JAMA</source>
          <year>2020</year>
          <volume>323</volume>
          <issue>12</issue>
          <fpage>1151</fpage>
          <lpage>1160</lpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://jamanetwork.com/journals/jama/fullarticle/2763292"/>
          </comment>
          <pub-id pub-id-type="doi">10.1001/jama.2020.1382</pub-id>
          <pub-id pub-id-type="medline">32207799</pub-id>
          <pub-id pub-id-type="pii">2763292</pub-id>
          <pub-id pub-id-type="pmcid">PMC7093766</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref28">
        <label>28</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Cavanaugh</surname>
              <given-names>JT</given-names>
            </name>
            <name name-style="western">
              <surname>Ellis</surname>
              <given-names>TD</given-names>
            </name>
            <name name-style="western">
              <surname>Earhart</surname>
              <given-names>GM</given-names>
            </name>
            <name name-style="western">
              <surname>Ford</surname>
              <given-names>MP</given-names>
            </name>
            <name name-style="western">
              <surname>Foreman</surname>
              <given-names>KB</given-names>
            </name>
            <name name-style="western">
              <surname>Dibble</surname>
              <given-names>LE</given-names>
            </name>
          </person-group>
          <article-title>Capturing ambulatory activity decline in Parkinson's disease</article-title>
          <source>J Neurol Phys Ther</source>
          <year>2012</year>
          <month>06</month>
          <volume>36</volume>
          <issue>2</issue>
          <fpage>51</fpage>
          <lpage>7</lpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://europepmc.org/abstract/MED/22592060"/>
          </comment>
          <pub-id pub-id-type="doi">10.1097/NPT.0b013e318254ba7a</pub-id>
          <pub-id pub-id-type="medline">22592060</pub-id>
          <pub-id pub-id-type="pii">01253086-201206000-00002</pub-id>
          <pub-id pub-id-type="pmcid">PMC3934648</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref29">
        <label>29</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Hobert</surname>
              <given-names>MA</given-names>
            </name>
            <name name-style="western">
              <surname>Nussbaum</surname>
              <given-names>S</given-names>
            </name>
            <name name-style="western">
              <surname>Heger</surname>
              <given-names>T</given-names>
            </name>
            <name name-style="western">
              <surname>Berg</surname>
              <given-names>D</given-names>
            </name>
            <name name-style="western">
              <surname>Maetzler</surname>
              <given-names>W</given-names>
            </name>
            <name name-style="western">
              <surname>Heinzel</surname>
              <given-names>S</given-names>
            </name>
          </person-group>
          <article-title>Progressive Gait Deficits in Parkinson's Disease: A Wearable-Based Biannual 5-Year Prospective Study</article-title>
          <source>Front Aging Neurosci</source>
          <year>2019</year>
          <volume>11</volume>
          <fpage>22</fpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://europepmc.org/abstract/MED/30814947"/>
          </comment>
          <pub-id pub-id-type="doi">10.3389/fnagi.2019.00022</pub-id>
          <pub-id pub-id-type="medline">30814947</pub-id>
          <pub-id pub-id-type="pmcid">PMC6381067</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref30">
        <label>30</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Popham</surname>
              <given-names>S</given-names>
            </name>
            <name name-style="western">
              <surname>Burq</surname>
              <given-names>M</given-names>
            </name>
            <name name-style="western">
              <surname>Rainaldi</surname>
              <given-names>EE</given-names>
            </name>
            <name name-style="western">
              <surname>Shin</surname>
              <given-names>S</given-names>
            </name>
            <name name-style="western">
              <surname>Dunn</surname>
              <given-names>J</given-names>
            </name>
            <name name-style="western">
              <surname>Kapur</surname>
              <given-names>R</given-names>
            </name>
          </person-group>
          <article-title>An algorithm to classify real-world ambulatory status from a wearable device using multimodal and demographically diverse data: validation study</article-title>
          <source>JMIR Biomed Eng</source>
          <year>2023</year>
          <volume>8</volume>
          <issue>1</issue>
          <fpage>e43726</fpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://biomedeng.jmir.org/2023/1/e43726"/>
          </comment>
          <pub-id pub-id-type="doi">10.2196/43726</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref31">
        <label>31</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Chen</surname>
              <given-names>C</given-names>
            </name>
            <name name-style="western">
              <surname>Kowahl</surname>
              <given-names>NR</given-names>
            </name>
            <name name-style="western">
              <surname>Rainaldi</surname>
              <given-names>E</given-names>
            </name>
            <name name-style="western">
              <surname>Burq</surname>
              <given-names>M</given-names>
            </name>
            <name name-style="western">
              <surname>Munsie</surname>
              <given-names>LM</given-names>
            </name>
            <name name-style="western">
              <surname>Battioui</surname>
              <given-names>C</given-names>
            </name>
            <name name-style="western">
              <surname>Wang</surname>
              <given-names>J</given-names>
            </name>
            <name name-style="western">
              <surname>Biglan</surname>
              <given-names>K</given-names>
            </name>
            <name name-style="western">
              <surname>Marks</surname>
              <given-names>WJ</given-names>
            </name>
            <name name-style="western">
              <surname>Kapur</surname>
              <given-names>R</given-names>
            </name>
          </person-group>
          <article-title>Wrist-worn sensor-based measurements for drug effect detection with small samples in people with lewy body dementia</article-title>
          <source>Parkinsonism Relat Disord</source>
          <year>2023</year>
          <volume>109</volume>
          <fpage>105355</fpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://www.prd-journal.com/article/S1353-8020(23)00078-0/fulltext"/>
          </comment>
          <pub-id pub-id-type="doi">10.1016/j.parkreldis.2023.105355</pub-id>
          <pub-id pub-id-type="medline">36905719</pub-id>
          <pub-id pub-id-type="pii">S1353-8020(23)00078-0</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref32">
        <label>32</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Treacy</surname>
              <given-names>D</given-names>
            </name>
            <name name-style="western">
              <surname>Hassett</surname>
              <given-names>L</given-names>
            </name>
            <name name-style="western">
              <surname>Schurr</surname>
              <given-names>K</given-names>
            </name>
            <name name-style="western">
              <surname>Chagpar</surname>
              <given-names>S</given-names>
            </name>
            <name name-style="western">
              <surname>Paul</surname>
              <given-names>SS</given-names>
            </name>
            <name name-style="western">
              <surname>Sherrington</surname>
              <given-names>C</given-names>
            </name>
          </person-group>
          <article-title>Validity of different activity monitors to count steps in an inpatient rehabilitation setting</article-title>
          <source>Phys Ther</source>
          <year>2017</year>
          <volume>97</volume>
          <issue>5</issue>
          <fpage>581</fpage>
          <lpage>588</lpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://academic.oup.com/ptj/article/97/5/581/3059635?login=false"/>
          </comment>
          <pub-id pub-id-type="doi">10.1093/ptj/pzx010</pub-id>
          <pub-id pub-id-type="medline">28339904</pub-id>
          <pub-id pub-id-type="pii">3059635</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref33">
        <label>33</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Block</surname>
              <given-names>VAJ</given-names>
            </name>
            <name name-style="western">
              <surname>Pitsch</surname>
              <given-names>E</given-names>
            </name>
            <name name-style="western">
              <surname>Tahir</surname>
              <given-names>P</given-names>
            </name>
            <name name-style="western">
              <surname>Cree</surname>
              <given-names>BAC</given-names>
            </name>
            <name name-style="western">
              <surname>Allen</surname>
              <given-names>DD</given-names>
            </name>
            <name name-style="western">
              <surname>Gelfand</surname>
              <given-names>JM</given-names>
            </name>
          </person-group>
          <article-title>Remote physical activity monitoring in neurological disease: a systematic review</article-title>
          <source>PLoS One</source>
          <year>2016</year>
          <volume>11</volume>
          <issue>4</issue>
          <fpage>e0154335</fpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0154335"/>
          </comment>
          <pub-id pub-id-type="doi">10.1371/journal.pone.0154335</pub-id>
          <pub-id pub-id-type="medline">27124611</pub-id>
          <pub-id pub-id-type="pii">PONE-D-15-55629</pub-id>
          <pub-id pub-id-type="pmcid">PMC4849800</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref34">
        <label>34</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <collab>Global Parkinson's Disease Survey (GPDS) Steering Committee</collab>
          </person-group>
          <article-title>Factors impacting on quality of life in Parkinson's disease: results from an international survey</article-title>
          <source>Mov Disord</source>
          <year>2002</year>
          <volume>17</volume>
          <issue>1</issue>
          <fpage>60</fpage>
          <lpage>67</lpage>
          <pub-id pub-id-type="doi">10.1002/mds.10010</pub-id>
          <pub-id pub-id-type="medline">11835440</pub-id>
          <pub-id pub-id-type="pii">10.1002/mds.10010</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref35">
        <label>35</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Lee</surname>
              <given-names>IM</given-names>
            </name>
            <name name-style="western">
              <surname>Buchner</surname>
              <given-names>DM</given-names>
            </name>
          </person-group>
          <article-title>The importance of walking to public health</article-title>
          <source>Med Sci Sports Exerc</source>
          <year>2008</year>
          <volume>40</volume>
          <issue>7 Suppl</issue>
          <fpage>S512</fpage>
          <lpage>S518</lpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://journals.lww.com/acsm-msse/Fulltext/2008/07002/The_Importance_of_Walking_to_Public_Health.2.aspx"/>
          </comment>
          <pub-id pub-id-type="doi">10.1249/MSS.0b013e31817c65d0</pub-id>
          <pub-id pub-id-type="medline">18562968</pub-id>
          <pub-id pub-id-type="pii">00005768-200807002-00002</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref36">
        <label>36</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Davoudi</surname>
              <given-names>A</given-names>
            </name>
            <name name-style="western">
              <surname>Mardini</surname>
              <given-names>MT</given-names>
            </name>
            <name name-style="western">
              <surname>Nelson</surname>
              <given-names>D</given-names>
            </name>
            <name name-style="western">
              <surname>Albinali</surname>
              <given-names>F</given-names>
            </name>
            <name name-style="western">
              <surname>Ranka</surname>
              <given-names>S</given-names>
            </name>
            <name name-style="western">
              <surname>Rashidi</surname>
              <given-names>P</given-names>
            </name>
            <name name-style="western">
              <surname>Manini</surname>
              <given-names>TM</given-names>
            </name>
          </person-group>
          <article-title>The effect of sensor placement and number on physical activity recognition and energy expenditure estimation in older adults: validation study</article-title>
          <source>JMIR Mhealth Uhealth</source>
          <year>2021</year>
          <volume>9</volume>
          <issue>5</issue>
          <fpage>e23681</fpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://mhealth.jmir.org/2021/5/e23681"/>
          </comment>
          <pub-id pub-id-type="doi">10.2196/23681</pub-id>
          <pub-id pub-id-type="medline">33938809</pub-id>
          <pub-id pub-id-type="pii">v9i5e23681</pub-id>
          <pub-id pub-id-type="pmcid">PMC8129874</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref37">
        <label>37</label>
        <nlm-citation citation-type="confproc">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Kulchyk</surname>
              <given-names>J</given-names>
            </name>
            <name name-style="western">
              <surname>Etemad</surname>
              <given-names>A</given-names>
            </name>
          </person-group>
          <article-title>2019 IEEE Sensors</article-title>
          <year>2019</year>
          <conf-name>Activity Recognition with Wearable Accelerometers using Deep Convolutional Neural Network and the Effect of Sensor Placement</conf-name>
          <conf-date>27-30 October 2019</conf-date>
          <conf-loc>Montreal, QC, Canada</conf-loc>
          <publisher-loc>Manhattan, New York, U.S</publisher-loc>
          <publisher-name>IEEE</publisher-name>
          <fpage>1</fpage>
          <lpage>4</lpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://ieeexplore.ieee.org/document/8956668"/>
          </comment>
          <pub-id pub-id-type="doi">10.1109/sensors43011.2019.8956668</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref38">
        <label>38</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Bennasar</surname>
              <given-names>M</given-names>
            </name>
            <name name-style="western">
              <surname>Price</surname>
              <given-names>BA</given-names>
            </name>
            <name name-style="western">
              <surname>Gooch</surname>
              <given-names>D</given-names>
            </name>
            <name name-style="western">
              <surname>Bandara</surname>
              <given-names>AK</given-names>
            </name>
            <name name-style="western">
              <surname>Nuseibeh</surname>
              <given-names>B</given-names>
            </name>
          </person-group>
          <article-title>Significant features for human activity recognition using tri-axial accelerometers</article-title>
          <source>Sensors (Basel)</source>
          <year>2022</year>
          <volume>22</volume>
          <issue>19</issue>
          <fpage>7482</fpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://www.mdpi.com/1424-8220/22/19/7482"/>
          </comment>
          <pub-id pub-id-type="doi">10.3390/s22197482</pub-id>
          <pub-id pub-id-type="medline">36236586</pub-id>
          <pub-id pub-id-type="pii">s22197482</pub-id>
          <pub-id pub-id-type="pmcid">PMC9572087</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref39">
        <label>39</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Straczkiewicz</surname>
              <given-names>M</given-names>
            </name>
            <name name-style="western">
              <surname>Glynn</surname>
              <given-names>NW</given-names>
            </name>
            <name name-style="western">
              <surname>Harezlak</surname>
              <given-names>J</given-names>
            </name>
          </person-group>
          <article-title>On Placement, Location and Orientation of Wrist-Worn Tri-Axial Accelerometers during Free-Living Measurements</article-title>
          <source>Sensors (Basel)</source>
          <year>2019</year>
          <month>05</month>
          <day>06</day>
          <volume>19</volume>
          <issue>9</issue>
          <fpage>2095</fpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://www.mdpi.com/resolver?pii=s19092095"/>
          </comment>
          <pub-id pub-id-type="doi">10.3390/s19092095</pub-id>
          <pub-id pub-id-type="medline">31064100</pub-id>
          <pub-id pub-id-type="pii">s19092095</pub-id>
          <pub-id pub-id-type="pmcid">PMC6538999</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref40">
        <label>40</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Hickey</surname>
              <given-names>A</given-names>
            </name>
            <name name-style="western">
              <surname>Del Din</surname>
              <given-names>S</given-names>
            </name>
            <name name-style="western">
              <surname>Rochester</surname>
              <given-names>L</given-names>
            </name>
            <name name-style="western">
              <surname>Godfrey</surname>
              <given-names>A</given-names>
            </name>
          </person-group>
          <article-title>Detecting free-living steps and walking bouts: validating an algorithm for macro gait analysis</article-title>
          <source>Physiol Meas</source>
          <year>2017</year>
          <volume>38</volume>
          <issue>1</issue>
          <fpage>N1</fpage>
          <lpage>N15</lpage>
          <pub-id pub-id-type="doi">10.1088/1361-6579/38/1/N1</pub-id>
          <pub-id pub-id-type="medline">27941238</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref41">
        <label>41</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Silsupadol</surname>
              <given-names>P</given-names>
            </name>
            <name name-style="western">
              <surname>Teja</surname>
              <given-names>K</given-names>
            </name>
            <name name-style="western">
              <surname>Lugade</surname>
              <given-names>V</given-names>
            </name>
          </person-group>
          <article-title>Reliability and validity of a smartphone-based assessment of gait parameters across walking speed and smartphone locations: body, bag, belt, hand, and pocket</article-title>
          <source>Gait Posture</source>
          <year>2017</year>
          <volume>58</volume>
          <fpage>516</fpage>
          <lpage>522</lpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://www.sciencedirect.com/science/article/abs/pii/S0966636217309359?via%3Dihub"/>
          </comment>
          <pub-id pub-id-type="doi">10.1016/j.gaitpost.2017.09.030</pub-id>
          <pub-id pub-id-type="medline">28961548</pub-id>
          <pub-id pub-id-type="pii">S0966-6362(17)30935-9</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref42">
        <label>42</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Donath</surname>
              <given-names>L</given-names>
            </name>
            <name name-style="western">
              <surname>Faude</surname>
              <given-names>O</given-names>
            </name>
            <name name-style="western">
              <surname>Lichtenstein</surname>
              <given-names>E</given-names>
            </name>
            <name name-style="western">
              <surname>Pagenstert</surname>
              <given-names>G</given-names>
            </name>
            <name name-style="western">
              <surname>Nüesch</surname>
              <given-names>C</given-names>
            </name>
            <name name-style="western">
              <surname>Mündermann</surname>
              <given-names>A</given-names>
            </name>
          </person-group>
          <article-title>Mobile inertial sensor based gait analysis: validity and reliability of spatiotemporal gait characteristics in healthy seniors</article-title>
          <source>Gait Posture</source>
          <year>2016</year>
          <volume>49</volume>
          <fpage>371</fpage>
          <lpage>374</lpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://www.sciencedirect.com/science/article/abs/pii/S0966636216304076?via%3Dihub"/>
          </comment>
          <pub-id pub-id-type="doi">10.1016/j.gaitpost.2016.07.269</pub-id>
          <pub-id pub-id-type="medline">27494305</pub-id>
          <pub-id pub-id-type="pii">S0966-6362(16)30407-6</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref43">
        <label>43</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Johnston</surname>
              <given-names>W</given-names>
            </name>
            <name name-style="western">
              <surname>Judice</surname>
              <given-names>PB</given-names>
            </name>
            <name name-style="western">
              <surname>García</surname>
              <given-names>PM</given-names>
            </name>
            <name name-style="western">
              <surname>Mühlen</surname>
              <given-names>JM</given-names>
            </name>
            <name name-style="western">
              <surname>Skovgaard</surname>
              <given-names>EL</given-names>
            </name>
            <name name-style="western">
              <surname>Stang</surname>
              <given-names>J</given-names>
            </name>
            <name name-style="western">
              <surname>Schumann</surname>
              <given-names>M</given-names>
            </name>
            <name name-style="western">
              <surname>Cheng</surname>
              <given-names>S</given-names>
            </name>
            <name name-style="western">
              <surname>Bloch</surname>
              <given-names>W</given-names>
            </name>
            <name name-style="western">
              <surname>Brønd</surname>
              <given-names>JC</given-names>
            </name>
            <name name-style="western">
              <surname>Ekelund</surname>
              <given-names>U</given-names>
            </name>
            <name name-style="western">
              <surname>Grøntved</surname>
              <given-names>A</given-names>
            </name>
            <name name-style="western">
              <surname>Caulfield</surname>
              <given-names>B</given-names>
            </name>
            <name name-style="western">
              <surname>Ortega</surname>
              <given-names>FB</given-names>
            </name>
            <name name-style="western">
              <surname>Sardinha</surname>
              <given-names>LB</given-names>
            </name>
          </person-group>
          <article-title>Recommendations for determining the validity of consumer wearable and smartphone step count: expert statement and checklist of the INTERLIVE network</article-title>
          <source>Br J Sports Med</source>
          <year>2021</year>
          <volume>55</volume>
          <issue>14</issue>
          <fpage>780</fpage>
          <lpage>793</lpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://bjsm.bmj.com/content/55/14/780"/>
          </comment>
          <pub-id pub-id-type="doi">10.1136/bjsports-2020-103147</pub-id>
          <pub-id pub-id-type="medline">33361276</pub-id>
          <pub-id pub-id-type="pii">bjsports-2020-103147</pub-id>
          <pub-id pub-id-type="pmcid">PMC8273687</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref44">
        <label>44</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Keadle</surname>
              <given-names>SK</given-names>
            </name>
            <name name-style="western">
              <surname>Lyden</surname>
              <given-names>KA</given-names>
            </name>
            <name name-style="western">
              <surname>Strath</surname>
              <given-names>SJ</given-names>
            </name>
            <name name-style="western">
              <surname>Staudenmayer</surname>
              <given-names>JW</given-names>
            </name>
            <name name-style="western">
              <surname>Freedson</surname>
              <given-names>PS</given-names>
            </name>
          </person-group>
          <article-title>A framework to evaluate devices that assess physical behavior</article-title>
          <source>Exerc Sport Sci Rev</source>
          <year>2019</year>
          <volume>47</volume>
          <issue>4</issue>
          <fpage>206</fpage>
          <lpage>214</lpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://journals.lww.com/acsm-essr/Fulltext/2019/10000/A_Framework_to_Evaluate_Devices_That_Assess.3.aspx"/>
          </comment>
          <pub-id pub-id-type="doi">10.1249/JES.0000000000000206</pub-id>
          <pub-id pub-id-type="medline">31524786</pub-id>
          <pub-id pub-id-type="pii">00003677-201910000-00003</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref45">
        <label>45</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Hartmann</surname>
              <given-names>A</given-names>
            </name>
            <name name-style="western">
              <surname>Luzi</surname>
              <given-names>S</given-names>
            </name>
            <name name-style="western">
              <surname>Murer</surname>
              <given-names>K</given-names>
            </name>
            <name name-style="western">
              <surname>de Bie</surname>
              <given-names>RA</given-names>
            </name>
            <name name-style="western">
              <surname>de Bruin</surname>
              <given-names>ED</given-names>
            </name>
          </person-group>
          <article-title>Concurrent validity of a trunk tri-axial accelerometer system for gait analysis in older adults</article-title>
          <source>Gait Posture</source>
          <year>2009</year>
          <volume>29</volume>
          <issue>3</issue>
          <fpage>444</fpage>
          <lpage>448</lpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://www.sciencedirect.com/science/article/abs/pii/S0966636208003652?via%3Dihub"/>
          </comment>
          <pub-id pub-id-type="doi">10.1016/j.gaitpost.2008.11.003</pub-id>
          <pub-id pub-id-type="medline">19070494</pub-id>
          <pub-id pub-id-type="pii">S0966-6362(08)00365-2</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref46">
        <label>46</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Kelkar</surname>
              <given-names>AA</given-names>
            </name>
            <name name-style="western">
              <surname>Spertus</surname>
              <given-names>J</given-names>
            </name>
            <name name-style="western">
              <surname>Pang</surname>
              <given-names>P</given-names>
            </name>
            <name name-style="western">
              <surname>Pierson</surname>
              <given-names>RF</given-names>
            </name>
            <name name-style="western">
              <surname>Cody</surname>
              <given-names>RJ</given-names>
            </name>
            <name name-style="western">
              <surname>Pina</surname>
              <given-names>IL</given-names>
            </name>
            <name name-style="western">
              <surname>Hernandez</surname>
              <given-names>A</given-names>
            </name>
            <name name-style="western">
              <surname>Butler</surname>
              <given-names>J</given-names>
            </name>
          </person-group>
          <article-title>Utility of patient-reported outcome instruments in heart failure</article-title>
          <source>JACC Heart Fail</source>
          <year>2016</year>
          <volume>4</volume>
          <issue>3</issue>
          <fpage>165</fpage>
          <lpage>175</lpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://www.sciencedirect.com/science/article/pii/S2213177915007313?via%3Dihub"/>
          </comment>
          <pub-id pub-id-type="doi">10.1016/j.jchf.2015.10.015</pub-id>
          <pub-id pub-id-type="medline">26874386</pub-id>
          <pub-id pub-id-type="pii">S2213-1779(15)00731-3</pub-id>
        </nlm-citation>
      </ref>
    </ref-list>
  </back>
</article>
