<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v2.0 20040830//EN" "journalpublishing.dtd"><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="2.0" xml:lang="en" article-type="research-article"><front><journal-meta><journal-id journal-id-type="nlm-ta">JMIR Hum Factors</journal-id><journal-id journal-id-type="publisher-id">humanfactors</journal-id><journal-id journal-id-type="index">6</journal-id><journal-title>JMIR Human Factors</journal-title><abbrev-journal-title>JMIR Hum Factors</abbrev-journal-title><issn pub-type="epub">2292-9495</issn><publisher><publisher-name>JMIR Publications</publisher-name><publisher-loc>Toronto, Canada</publisher-loc></publisher></journal-meta><article-meta><article-id pub-id-type="publisher-id">v13i1e77033</article-id><article-id pub-id-type="doi">10.2196/77033</article-id><article-categories><subj-group subj-group-type="heading"><subject>Original Paper</subject></subj-group></article-categories><title-group><article-title>Evaluation of a Contactless Sleep Monitoring Device for Sleep Stage Detection at Home in a Healthy Population: Prospective Study in Free-Living Conditions</article-title></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><name name-style="western"><surname>Stefanos</surname><given-names>Marie-Ange</given-names></name><degrees>MSc</degrees><xref ref-type="aff" rid="aff1">1</xref><xref ref-type="aff" rid="aff2">2</xref><xref ref-type="aff" rid="aff3">3</xref></contrib><contrib contrib-type="author"><name name-style="western"><surname>de Laboulaye</surname><given-names>Guillaume</given-names></name><degrees>MSc</degrees><xref ref-type="aff" rid="aff3">3</xref></contrib><contrib contrib-type="author"><name name-style="western"><surname>Campo</surname><given-names>David</given-names></name><degrees>PhD</degrees><xref ref-type="aff" rid="aff3">3</xref></contrib><contrib contrib-type="author"><name name-style="western"><surname>de Gourcuff</surname><given-names>Martin</given-names></name><degrees>MSc</degrees><xref ref-type="aff" rid="aff3">3</xref></contrib><contrib contrib-type="author"><name name-style="western"><surname>Escourrou</surname><given-names>Pierre</given-names></name><degrees>MD, PhD</degrees><xref ref-type="aff" rid="aff3">3</xref><xref ref-type="aff" rid="aff4">4</xref></contrib><contrib contrib-type="author"><name name-style="western"><surname>Matrot</surname><given-names>Boris</given-names></name><degrees>PhD</degrees><xref ref-type="aff" rid="aff1">1</xref></contrib><contrib contrib-type="author"><name name-style="western"><surname>Islind</surname><given-names>Anna Sigridur</given-names></name><degrees>PhD</degrees><xref ref-type="aff" rid="aff2">2</xref></contrib><contrib contrib-type="author"><name name-style="western"><surname>Geoffroy</surname><given-names>Pierre Alexis</given-names></name><degrees>MD, PhD</degrees><xref ref-type="aff" rid="aff1">1</xref><xref ref-type="aff" rid="aff5">5</xref><xref ref-type="aff" rid="aff6">6</xref></contrib></contrib-group><aff id="aff1"><institution>Inserm, F-75019, NeuroDiderot, SleepCmd, Universit&#x00E9; Paris Cit&#x00E9;</institution><addr-line>Paris</addr-line><country>France</country></aff><aff id="aff2"><institution>Department of Computer Science, Reykjav&#x00ED;k University</institution><addr-line>Reykjavik</addr-line><country>Iceland</country></aff><aff id="aff3"><institution>Withings</institution><addr-line>2 rue Maurice Hartmann</addr-line><addr-line>Issy-les-Moulineaux</addr-line><country>France</country></aff><aff id="aff4"><institution>Centre Interdisciplinaire du Sommeil</institution><addr-line>Paris</addr-line><country>France</country></aff><aff id="aff5"><institution>D&#x00E9;partement de Psychiatrie et D&#x2019;addictologie, Hopital Bichat - Claude Bernard, F-75018, AP-HP, GHU Paris Nord, DMU Neurosciences</institution><addr-line>Paris</addr-line><country>France</country></aff><aff id="aff6"><institution>GHU Paris - Psychiatry and Neurosciences, Centre ChronoS</institution><addr-line>Paris</addr-line><country>France</country></aff><contrib-group><contrib contrib-type="editor"><name name-style="western"><surname>Waterson</surname><given-names>James</given-names></name></contrib></contrib-group><contrib-group><contrib contrib-type="reviewer"><name name-style="western"><surname>Nelson</surname><given-names>Benjamin W</given-names></name></contrib><contrib contrib-type="reviewer"><name name-style="western"><surname>Etindele Sosso</surname><given-names>F A</given-names></name></contrib><contrib contrib-type="reviewer"><name name-style="western"><surname>Pinilla</surname><given-names>Lucia</given-names></name></contrib></contrib-group><author-notes><corresp>Correspondence to Marie-Ange Stefanos, MSc, Withings, 2 rue Maurice Hartmann, Issy-les-Moulineaux, 92130, France, 33 141460460; <email>marieangestefanos@gmail.com</email></corresp></author-notes><pub-date pub-type="collection"><year>2026</year></pub-date><pub-date pub-type="epub"><day>2</day><month>4</month><year>2026</year></pub-date><volume>13</volume><elocation-id>e77033</elocation-id><history><date date-type="received"><day>06</day><month>05</month><year>2025</year></date><date date-type="rev-recd"><day>10</day><month>01</month><year>2026</year></date><date date-type="accepted"><day>26</day><month>01</month><year>2026</year></date></history><copyright-statement>&#x00A9; Marie-Ange Stefanos, Guillaume de Laboulaye, David Campo, Martin de Gourcuff, Pierre Escourrou, Boris Matrot, Anna Sigridur Islind, Pierre Alexis Geoffroy. Originally published in JMIR Human Factors (<ext-link ext-link-type="uri" xlink:href="https://humanfactors.jmir.org">https://humanfactors.jmir.org</ext-link>), 2.4.2026. </copyright-statement><copyright-year>2026</copyright-year><license license-type="open-access" xlink:href="https://creativecommons.org/licenses/by/4.0/"><p>This is an open-access article distributed under the terms of the Creative Commons Attribution License (<ext-link ext-link-type="uri" xlink:href="https://creativecommons.org/licenses/by/4.0/">https://creativecommons.org/licenses/by/4.0/</ext-link>), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work, first published in JMIR Human Factors, is properly cited. The complete bibliographic information, a link to the original publication on <ext-link ext-link-type="uri" xlink:href="https://humanfactors.jmir.org">https://humanfactors.jmir.org</ext-link>, as well as this copyright and license information must be included.</p></license><self-uri xlink:type="simple" xlink:href="https://humanfactors.jmir.org/2026/1/e77033"/><abstract><sec><title>Background</title><p>Sleep is essential for overall health and well-being, but assessing sleep architecture is often costly and time-consuming, relying primarily on polysomnography (PSG). While wrist-worn wearables offer alternatives, they face limitations regarding user compliance, such as battery charging and physical discomfort. Nearable devices address these burdens, but they regularly lack rigorous validation, especially in real-world settings.</p></sec><sec><title>Objective</title><p>This study evaluates the accuracy and reliability of the Withings Sleep Analyzer (WSA), a contactless sleep monitoring device, compared to PSG in a home setting using a large and diverse cohort of healthy individuals.</p></sec><sec sec-type="methods"><title>Methods</title><p>A total of 117 healthy volunteers (69 women; mean 39.9, SD 11.4 years), prospectively recruited from the general population, underwent home-based PSG and simultaneous WSA recording. The study was conducted under free-living conditions, without constraints on substance intake, prebedtime activity, or forced sleep schedules. The main outcomes were the device&#x2019;s performance in sleep-wake distinction and sleep stage identification using accuracy, kappa, sensitivity, specificity, and the mean absolute error of sleep measures on the entire population and demographic, clinical, and environmental subgroups.</p></sec><sec sec-type="results"><title>Results</title><p>WSA demonstrates high sensitivity (93%, 95% CI 92%-94%) for sleep detection and moderate sensitivity (73%, 95% CI 69%-77%) for wakefulness, achieving an overall accuracy of 87% (95% CI 86%-87%) for sleep-wake distinction. The device showed consistent performance across various demographic subgroups, including different age, BMI, mattress, and sleep arrangements (with or without bed partner) categories. Challenges were noted in accurately classifying specific sleep stages, particularly in distinguishing between light and deep sleep, with a mean accuracy of 63% (95% CI 62%-65%) and a Cohen &#x03BA; of 0.49 (95% CI 0.47-0.51). The WSA tended to overestimate total sleep time (20 min, 95% CI 10 min to 31 min) and light sleep (1 h 21 min, 95% CI 1 h 8 min to 1 h 36 min) while underestimating rapid eye movement (&#x2212;15 min, 95% CI &#x2212;23 min to &#x2212;8 min) and deep sleep (&#x2212;46 min, 95% CI &#x2212;59 min to &#x2212;34 min) durations. Disagreements between expert reviewers were mirrored in part by the WSA&#x2019;s misclassifications. Participants reported altered perceived sleep quality during the night with the PSG, suggesting discomfort during sleep.</p></sec><sec sec-type="conclusions"><title>Conclusions</title><p>Being contactless and placed under the mattress, the WSA offers a promising approach to long-term sleep monitoring in natural home environments. It shows competitive performance in sleep-wake and sleep stage identification compared to other consumer devices. Progress in wearable and nearable devices is necessary to enhance their accuracy to better support the monitoring of populations with impaired sleep, although limited by an imperfect gold standard. This work also emphasizes the importance of using large, diverse, and challenging datasets, as well as the need for a standardized methodology for accurate sleep stage classification.</p></sec></abstract><kwd-group><kwd>health</kwd><kwd>informatics</kwd><kwd>nearable</kwd><kwd>wearable</kwd><kwd>sleep stage</kwd><kwd>home polysomnography</kwd><kwd>performance assessment</kwd><kwd>healthy population</kwd><kwd>sleep monitoring device</kwd></kwd-group></article-meta></front><body><sec id="s1" sec-type="intro"><title>Introduction</title><p>Sleep is an essential component of human health and plays an important role in daily functioning and overall well-being [<xref ref-type="bibr" rid="ref1">1</xref>]. Poor sleep quality can significantly impact multiple aspects of life, including physical health, social interactions, and emotional regulation [<xref ref-type="bibr" rid="ref2">2</xref>,<xref ref-type="bibr" rid="ref3">3</xref>]. Moreover, poor sleep quality can diminish alertness and cognitive function, increasing the risk of accidents. Furthermore, inadequate sleep has been linked to numerous health issues, such as metabolic disorders, cardiovascular disease, neurocognitive impairments, and mental health challenges [<xref ref-type="bibr" rid="ref4">4</xref>]. In severe cases, poor sleep quality can lead to critical outcomes, including an increased risk of suicide [<xref ref-type="bibr" rid="ref5">5</xref>]. Despite the recognized importance of sleep, sleep-related difficulties remain common in the general population [<xref ref-type="bibr" rid="ref6">6</xref>]. Approximately 30% of adults experience at least one symptom of nocturnal insomnia on a chronic basis [<xref ref-type="bibr" rid="ref6">6</xref>], over 15% report sleepiness that affects daily activities [<xref ref-type="bibr" rid="ref7">7</xref>], and more than 10% experience obstructive sleep apnea [<xref ref-type="bibr" rid="ref8">8</xref>].</p><p>Polysomnography (PSG), considered the gold standard for identifying the micro and macro sleep architecture, records a variety of signals (electroencephalogram [EEG], electrooculogram [EOG], electromyogram [EMG], electrocardiogram [ECG], pulse oximetry, air flow, and breathing effort [<xref ref-type="bibr" rid="ref9">9</xref>]). As the hypnogram helps physicians identify abnormal sleep patterns, quantify sleep fragmentation, and analyze sleep stage distribution, it supports the diagnosis of various sleep disorders, such as sleep-related breathing disorders, narcolepsy, hypersomnia, and disturbing sleep-related behaviors [<xref ref-type="bibr" rid="ref10">10</xref>].</p><p>PSG has limitations. It often involves extensive setup time and significant costs, making it less feasible for routine monitoring [<xref ref-type="bibr" rid="ref11">11</xref>]. It is scored manually, which is a labor-intensive process that can lead to long waiting times and has been shown to be prone to human error [<xref ref-type="bibr" rid="ref12">12</xref>]. Additionally, since it is typically conducted over just a few nights, it fails to capture the full picture of an individual&#x2019;s circadian rhythm and night-to-night variability [<xref ref-type="bibr" rid="ref13">13</xref>,<xref ref-type="bibr" rid="ref14">14</xref>]. In most cases, PSG is conducted in a sleep lab with numerous sensors that can disrupt natural sleep patterns [<xref ref-type="bibr" rid="ref15">15</xref>]. For all these reasons, PSG results in data that may not accurately represent a person&#x2019;s typical sleep in their own home [<xref ref-type="bibr" rid="ref16">16</xref>].</p><p>Ambulatory PSG attempts to address these limitations. Lab studies support its accuracy [<xref ref-type="bibr" rid="ref17">17</xref>-<xref ref-type="bibr" rid="ref19">19</xref>]. However, in an uncontrolled home setting, sleep metrics may differ; for example, total sleep time (TST) can increase, potentially due to the absence of lab-induced constraints on waking time [<xref ref-type="bibr" rid="ref20">20</xref>].</p><p>The need for more accessible and cost-effective solutions for multinight sleep monitoring remains, driven by the desire to enhance our understanding of sleep quality and facilitate the identification of potential sleep disorders [<xref ref-type="bibr" rid="ref14">14</xref>,<xref ref-type="bibr" rid="ref21">21</xref>]. Home-based sleep monitoring devices can enable continuous tracking in the comfort of one&#x2019;s own home, while providing data that reflect real-life conditions more accurately than laboratory-based examinations [<xref ref-type="bibr" rid="ref22">22</xref>]. This can provide a more realistic picture of an individual&#x2019;s sleep patterns and helps to address the limitations of traditional sleep studies [<xref ref-type="bibr" rid="ref23">23</xref>].</p><p>To address the challenges of cost and complexity in multinight assessments, wearable sleep devices are commonly used to detect sleep and wake states. These devices increasingly combine actigraphy, which tracks body movements [<xref ref-type="bibr" rid="ref16">16</xref>], with photoplethysmography (PPG) sensors to increase the accuracy of sleep measures estimation [<xref ref-type="bibr" rid="ref23">23</xref>]. These devices still show two limitations. First, they struggle to accurately differentiate between wakefulness and sleep when individuals remain still while awake [<xref ref-type="bibr" rid="ref24">24</xref>]. Second, wearable devices require users to maintain proper charging and wearing, leading to frequent data loss and inconsistent performance [<xref ref-type="bibr" rid="ref25">25</xref>]. In contrast, nearables, which are not in direct contact with the individual, eliminate the need for charging or wearing a device. Nearables for measuring sleep are typically positioned under the mattress or at the bedside and require minimal intervention after setup.</p><p>Withings Sleep Analyzer (WSA) is a nearable device designed to provide a noninvasive alternative for monitoring sleep stages over consecutive nights. Despite the proliferation of wearable and nearable sleep-tracking devices, there is a notable lack of rigorous evaluation of the algorithms, leading to concerns about data accuracy and reliability [<xref ref-type="bibr" rid="ref26">26</xref>,<xref ref-type="bibr" rid="ref27">27</xref>]. To date, the WSA performance to detect apnea has been evaluated in laboratory conditions [<xref ref-type="bibr" rid="ref28">28</xref>-<xref ref-type="bibr" rid="ref32">32</xref>], for which it is European Conformity (Conformit&#x00E9; Europ&#x00E9;enne) marked and Food and Drug Administration&#x2013;cleared. In addition, it has been assessed for nocturnal sleep periods detection [<xref ref-type="bibr" rid="ref33">33</xref>] and cardiorespiratory monitoring [<xref ref-type="bibr" rid="ref34">34</xref>]. However, validation of its sleep stage detection algorithm remains limited. This study, therefore, aims to assess the WSA sleep stage identification algorithm in a real-world home setting in a cohort of 117 healthy adult participants.</p><p>There are several important methodological issues addressed in this work. Existing research in sleep-tracking technologies highlights several persistent problems and limitations. Many studies, such as those on the WatchPAT [<xref ref-type="bibr" rid="ref35">35</xref>] and Somnofy [<xref ref-type="bibr" rid="ref36">36</xref>] devices, suggest potential utility but often lack comprehensive validation across diverse populations and real-world settings. Evaluations of consumer-grade devices, like those conducted by Chinoy et al [<xref ref-type="bibr" rid="ref37">37</xref>] and Kainec et al [<xref ref-type="bibr" rid="ref38">38</xref>], are frequently limited by small sample sizes and strict exclusion criteria (young individuals with controlled caffeine, alcohol, screen time, and sleep regularity), which limit the generalizability of their findings. These studies typically occur in controlled environments, such as sleep labs, which do not accurately reflect regular user conditions at home.</p><p>Moreover, the assessment of device accuracy in these studies is often complicated by two distinct factors. First, the absence of synchronized epoch-by-epoch data in some reports limits performance evaluation to night-scale sleep measures, such as TST, precluding the calculation of detailed classification metrics (eg, accuracy, sensitivity, and specificity). Second, the practice of using lights-off and lights-on times to define the temporal analysis window, which excludes all data outside this interval, impairs the reliability of the computed error for metrics like sleep onset latency. This method indeed assumes observable in-bed time is equivalent to the intention to initiate sleep, which cannot be passively identified in free-living conditions [<xref ref-type="bibr" rid="ref39">39</xref>].</p><p>Recent publications emphasize the importance of assessing these devices under everyday conditions, aligning with our work (eg, [<xref ref-type="bibr" rid="ref40">40</xref>]). Other research emphasizes the need for standardized evaluation protocols and methodological consistency across studies, reinforcing the approach taken in our research [<xref ref-type="bibr" rid="ref41">41</xref>-<xref ref-type="bibr" rid="ref43">43</xref>]. These studies collectively highlight the critical need for standardized and rigorous evaluation methods in sleep monitoring technology. Benchmarking efforts of devices are also being addressed, as recent studies manifest [<xref ref-type="bibr" rid="ref37">37</xref>,<xref ref-type="bibr" rid="ref38">38</xref>,<xref ref-type="bibr" rid="ref44">44</xref>-<xref ref-type="bibr" rid="ref47">47</xref>].</p><p>Our study contributes to the growing literature on sleep tracking by assessing the WSA&#x2019;s performance in a home setting, on a large and diverse sample of healthy individuals, in free-living conditions, that is, without constraints about substance intake, activity before bed, or forced sleeping period, providing insights into the device&#x2019;s accuracy and reliability in real-world conditions. The primary goal is to evaluate WSA&#x2019;s performance using classification metrics and mean absolute error (MAE) on standard sleep metrics [<xref ref-type="bibr" rid="ref48">48</xref>]. Additionally, we compare performance across subgroups based on demographic and clinical characteristics, such as sex, age, BMI, bed partner presence, mattress type, but also Pittsburgh Sleep Quality Index (PSQI) score [<xref ref-type="bibr" rid="ref49">49</xref>], mattress, and thickness.</p><p>By addressing these gaps, our study enhances the understanding of WSA&#x2019;s capabilities and contributes to the development of more reliable and user-friendly sleep-tracking devices.</p></sec><sec id="s2" sec-type="methods"><title>Methods</title><sec id="s2-1"><title>Ethical Considerations</title><p>Data were collected during a clinical study approved by the French Institutional Review Board (approval number: 2018-A03129-46) and conducted by Withings from 2020 to 2022. The inclusion process for the study was conducted prospectively by a third party, a general-purpose survey company owning listings of self-declared individuals from the general population. Participants were contacted based on the inclusion and exclusion criteria. In particular, the contacted persons had to have no preexisting medical conditions that would necessitate a PSG examination, and inclusion criteria aimed to ensure a balanced distribution of BMI within each age group. The cohort consisted of a consecutive series of 194 volunteers who provided informed consent. To guarantee data privacy, a unique, randomized anonymization code was assigned to each participant (used for both WSA and PSG data correspondence). Withings only had access to these pseudonymized datasets and never had access to direct identifiers. No compensation from Withings was provided to the participants.</p></sec><sec id="s2-2"><title>Dataset</title><sec id="s2-2-1"><title>Participants</title><p>A total of 194 participants slept for the first night at home with WSA and the CID-LXe portable PSG (CIDELEC), both installed by a technician the evening before the recording. The night after that, the participants slept at home with the WSA, without the PSG. Each participant was asked to answer once to the PSQI questionnaire upon enrollment. After each night, participants were asked to complete a survey addressing the following: their sleep quality for that night, a comparison of that night&#x2019;s sleep quality to their usual sleep, whether they took sleeping pills, and any sleep disturbances related to the sensors.</p><p>As illustrated in the flowchart (<xref ref-type="fig" rid="figure1">Figure 1</xref>), several sources of data loss have led to the inclusion of 117 participants in this analysis. This trial was notably affected by data collection issues due to a dedicated firmware meant to collect high-frequency sensor data (reason for exclusion A). Unlike the commercial version which transmits aggregated data, the devices in this study were programmed to upload raw, high-frequency sensor signals, which introduced connectivity issues detailed in the Limitations section. We performed Little&#x2019;s missing completely at random (MCAR) test, which did not reject the null hypothesis of MCAR data due to reasons A, C, and D (<italic>P</italic>&#x003E;.05). While a statistically significant result was observed for reason B (<italic>P</italic>=.04), this subgroup comprised only 4 participants and was therefore unlikely to represent a source of systematic bias (see Section A of <xref ref-type="supplementary-material" rid="app1">Multimedia Appendix 1</xref> for detailed results).</p><fig position="float" id="figure1"><label>Figure 1.</label><caption><p>Study inclusions flowchart. ECG: electrocardiogram; EEG: electroencephalogram; PSG: polysomnography; WSA: Withings Sleep Analyzer.</p></caption><graphic alt-version="no" mimetype="image" position="float" xlink:type="simple" xlink:href="humanfactors_v13i1e77033_fig01.png"/></fig></sec><sec id="s2-2-2"><title>Procedure and Study Design</title><p>WSA sampled the raw data from the pressure sensors at 250 Hz and preprocessed data from the microphone at 8 Hz. The reference device was CID-LXe PSG (CIDELEC) that recorded the following signals: 3 EEG, 1 ECG, 2 EOG, 1 submental EMG, and ambient light. Based on experience from past investigations, the digital oximeter and the nasal cannula are among the most sleep-disruptive sensors during PSG, even in a home setting. To minimize this sleep disruption and obtain the most natural possible sleep, PSG was therefore done at home with only EEG, EMG, ECG, and ambient light sensors. As sleep stage annotations from expert reviewers are based on EEG and light sensors only [<xref ref-type="bibr" rid="ref50">50</xref>], the gold standard reference quality is not affected by the removal of the oximeter and the nasal cannula.</p></sec></sec><sec id="s2-3"><title>Data Processing</title><p>WSA is designed to identify sleep stages over 6-minute windows. As a result, this analysis focuses on evaluating WSA&#x2019;s performance in detecting stages longer than 6 minutes. It should be kept in mind that sleep stages shorter than this are ignored by the device in this study. In addition, WSA does not distinguish stages N1 and N2, so for the aim of comparison, the consensus sleep stages N1 and N2 obtained from the PSG were combined into the &#x201C;light&#x201D; category. Rapid eye movement (REM) and awake stages of the WSA and the consensus are directly comparable, and N3 is compared with the stage &#x201C;deep sleep&#x201D; from the WSA. The resulting stages are illustrated in <xref ref-type="fig" rid="figure2">Figure 2</xref>.</p><fig position="float" id="figure2"><label>Figure 2.</label><caption><p>Example of hypnogram (participant 20211029_1) showing WSA sleep stages and the reference (PSG consensus). PSG: polysomnography; REM: rapid eye movement (sleep stage); WSA: Withings Sleep Analyzer.</p></caption><graphic alt-version="no" mimetype="image" position="float" xlink:type="simple" xlink:href="humanfactors_v13i1e77033_fig02.png"/></fig><p>Two independent certified sleep technologists annotated the PSG signals in 30-second epochs, classifying sleep stages as N1, N2, N3, REM, and awake, following the American Academy of Sleep Medicine (AASM) scoring manual [<xref ref-type="bibr" rid="ref48">48</xref>]. A third professional reviewed the 2 initial readings and established a consensus for reference data. Sleep stage comparisons were performed over windows of 30 seconds. To evaluate WSA&#x2019;s performance in detecting sleep stages longer than 6 minutes, consensus data were smoothed by selecting for each 6-minute window the stage with the highest occurrence of 30-second epochs. For more details about the procedure, please refer to Section A of <xref ref-type="supplementary-material" rid="app1">Multimedia Appendix 1</xref>.</p><p>In addition to standard sleep quality measures calculated over the night, such as TST and the duration of each stage, evaluating stage classification required synchronizing epoch-by-epoch data from both devices over time. Synchronization of the clocks of the devices was obtained by maximizing the correlation of the breathing signals of the two devices [<xref ref-type="bibr" rid="ref51">51</xref>]. To verify the robustness of our breathing-based synchronization, we assessed the impact of temporal shifts (up to &#x00B1;90 seconds) on classification performance [<xref ref-type="bibr" rid="ref39">39</xref>,<xref ref-type="bibr" rid="ref52">52</xref>]. This sensitivity analysis revealed negligible variations, with the SD for sensitivity and specificity across all sleep stages remaining below 0.005. Details of the procedure can be found in Section A of <xref ref-type="supplementary-material" rid="app1">Multimedia Appendix 1</xref>.</p><p>An example hypnogram is presented in <xref ref-type="fig" rid="figure2">Figure 2</xref>, showing the smoothed, PSG-based consensus in red and WSA sleep stages in blue. WSA indicates bed absence/presence, marked respectively by a red and yellow background, information which is absent from the PSG data. The consensus annotations use instead the events lights-on/off detected by the ambient light sensor of the PSG as proxies for bed-in and bed-out events. For further information on challenges arising from using lights-off/on timestamps as proxies for bed presence, please refer to Section A of <xref ref-type="supplementary-material" rid="app1">Multimedia Appendix 1</xref>.</p></sec><sec id="s2-4"><title>Performance Evaluation Metrics and Tools</title><p>Standard sleep quality measures used for this analysis and based on the AASM scoring manual [<xref ref-type="bibr" rid="ref48">48</xref>] are the following: total sleep time, time spent in each sleep stage (TIREM, TILight, TIDeep, and TIWake), proportion of the time spent in each sleep stage compared to total sleep time (PIREM, PILight, PIDeep, and PIWake), and number of episodes in each sleep stage (NEREM, NELight, NEDeep, and NEWake) [<xref ref-type="bibr" rid="ref50">50</xref>]. Each of these measures has been computed by each device (PSG and WSA) and then compared using the MAE and a Bland-Altman analysis, described in Section B of <xref ref-type="supplementary-material" rid="app1">Multimedia Appendix 1</xref>.</p><p>Epoch-by-epoch agreement is assessed using standard classification metrics. Subgroup analyses were conducted to determine whether WSA performance is affected by demographic, clinical, and environmental factors. Details regarding the evaluation metrics and subgroup analyses are available in Sections B and C of <xref ref-type="supplementary-material" rid="app1">Multimedia Appendix 1</xref>.</p><p>To compare the median MAE between different groups (categories of a given metadata as listed in Table S3 in <xref ref-type="supplementary-material" rid="app1">Multimedia Appendix 1</xref>), a Kruskal-Wallis test has been performed on the MAE obtained on all the metadata described in Table S3 in <xref ref-type="supplementary-material" rid="app1">Multimedia Appendix 1</xref> for each of the following sleep quality measures (TST, TIREM, TILight, TIDeep, PIREM, PILight, and PIDeep) and for the number of episodes in each sleep stage.</p><p>To compare the MAE variance between different groups, a Brown-Forsythe test has been performed on the same data for the same sleep quality measures. The Holm-Bonferroni correction is used after both statistical tests to address the issue of multiple comparisons.</p></sec></sec><sec id="s3" sec-type="results"><title>Results</title><sec id="s3-1"><title>Patient Characteristics</title><p>Demographic and clinical data are summarized in <xref ref-type="table" rid="table1">Table 1</xref> for the population included in the analyses.</p><table-wrap id="t1" position="float"><label>Table 1.</label><caption><p>Demographic characteristics and clinical data for the entire population (N=117).</p></caption><table id="table1" frame="hsides" rules="groups"><thead><tr><td align="left" valign="top">Characteristics</td><td align="left" valign="top">Values</td></tr></thead><tbody><tr><td align="left" valign="top">Demographics</td><td align="left" valign="top"/></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Age (years)</td><td align="left" valign="top"/></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Mean (SD)</td><td align="char" char="." valign="top">39.9 (11.4)</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Min-max</td><td align="char" char="." valign="top">19&#x2010;69</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Height (cm)</td><td align="left" valign="top"/></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Mean (SD)</td><td align="char" char="." valign="top">171.6 (8.3)</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Min-max</td><td align="char" char="." valign="top">153&#x2010;194</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Weight (kg)</td><td align="left" valign="top"/></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Mean (SD)</td><td align="char" char="." valign="top">70.4 (12.0)</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Min-max</td><td align="char" char="." valign="top">49&#x2010;103</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>BMI (kg/m&#x00B2;)</td><td align="left" valign="top"/></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Mean (SD)</td><td align="char" char="." valign="top">23.9 (3.3)</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Min-max</td><td align="char" char="." valign="top">17.9&#x2010;30.9</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Sex, n (%)</td><td align="left" valign="top"/></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Male</td><td align="char" char="." valign="top">48 (41)</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Female</td><td align="char" char="." valign="top">69 (59)</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Skin type<sup><xref ref-type="table-fn" rid="table1fn1">a</xref></sup>, n (%)</td><td align="left" valign="top"/></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Skin type 1</td><td align="char" char="." valign="top">85 (75)</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Skin type 2</td><td align="char" char="." valign="top">21 (18)</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Skin type 3</td><td align="char" char="." valign="top">8 (7)</td></tr><tr><td align="left" valign="top">Known pathologies, n (%)</td><td align="left" valign="top"/></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Asthma</td><td align="char" char="." valign="top">5 (4)</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Arterial hypertension</td><td align="char" char="." valign="top">3 (&#x003C;3)</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Bipolar disorder</td><td align="char" char="." valign="top">1 (&#x003C;1)</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Ulcerative colitis</td><td align="char" char="." valign="top">1 (&#x003C;1)</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Ankylosing spondylitis</td><td align="char" char="." valign="top">1 (&#x003C;1)</td></tr><tr><td align="left" valign="top">Pathologies, n (%)</td><td align="left" valign="top"/></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Cardiovascular<sup><xref ref-type="table-fn" rid="table1fn2">b</xref></sup></td><td align="char" char="." valign="top">4 (4)</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Neurological<sup><xref ref-type="table-fn" rid="table1fn3">c</xref></sup></td><td align="char" char="." valign="top">0 (0)</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Digestive<sup><xref ref-type="table-fn" rid="table1fn4">d</xref></sup></td><td align="char" char="." valign="top">0 (0)</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Metabolic<sup><xref ref-type="table-fn" rid="table1fn5">e</xref></sup></td><td align="char" char="." valign="top">2 (2)</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Psychiatric<sup><xref ref-type="table-fn" rid="table1fn6">f</xref></sup></td><td align="char" char="." valign="top">0 (0)</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Other</td><td align="char" char="." valign="top">6 (5)</td></tr><tr><td align="left" valign="top">PSQI<sup><xref ref-type="table-fn" rid="table1fn7">g</xref></sup> questionnaire [<xref ref-type="bibr" rid="ref49">49</xref>]</td><td align="left" valign="top"/></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>PSQI score</td><td align="left" valign="top"/></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Mean (SD)</td><td align="char" char="." valign="top">6.0 (2.9)</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Min-max</td><td align="char" char="." valign="top">0&#x2010;15</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Component 1: subjective sleep quality</td><td align="left" valign="top"/></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Mean (SD)</td><td align="char" char="." valign="top">1.2 (0.7)</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Min-max</td><td align="char" char="." valign="top">0&#x2010;3</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Component 2: sleep latency</td><td align="left" valign="top"/></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Mean (SD)</td><td align="char" char="." valign="top">1.3 (0.9)</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Min-max</td><td align="char" char="." valign="top">0&#x2010;3</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Component 3: sleep duration</td><td align="left" valign="top"/></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Mean (SD)</td><td align="char" char="." valign="top">0.8 (0.8)</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Min-max</td><td align="char" char="." valign="top">0&#x2010;2</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Component 4: habitual sleep efficiency</td><td align="left" valign="top"/></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Mean (SD)</td><td align="char" char="." valign="top">0.4 (0.7)</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Min-max</td><td align="char" char="." valign="top">0&#x2010;3</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Component 5: sleep disturbances</td><td align="left" valign="top"/></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Mean (SD)</td><td align="char" char="." valign="top">1.3 (0.5)</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Min-max</td><td align="char" char="." valign="top">0&#x2010;3</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Component 6: use of sleeping medications</td><td align="left" valign="top"/></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Mean (SD)</td><td align="char" char="." valign="top">0.2 (0.6)</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Min-max</td><td align="char" char="." valign="top">0&#x2010;3</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Component 7: daytime dysfunction</td><td align="left" valign="top"/></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Mean (SD)</td><td align="char" char="." valign="top">0.9 (0.8)</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Min-max</td><td align="char" char="." valign="top">0&#x2010;3</td></tr><tr><td align="left" valign="top">Medications, n (%)</td><td align="left" valign="top"/></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Antihypertensive</td><td align="char" char="." valign="top">3 (3)</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Antidepressant</td><td align="char" char="." valign="top">2 (2)</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Hypnotics</td><td align="char" char="." valign="top">1 (1)</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Corticoid</td><td align="char" char="." valign="top">1 (1)</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Antiepileptic</td><td align="char" char="." valign="top">1 (1)</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Antipsychotic</td><td align="char" char="." valign="top">1 (1)</td></tr><tr><td align="left" valign="top">Mattress type, n (%)</td><td align="left" valign="top"/></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Foam</td><td align="char" char="." valign="top">41 (35)</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Spring</td><td align="char" char="." valign="top">29 (25)</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Latex</td><td align="char" char="." valign="top">24 (21)</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Memory foam</td><td align="char" char="." valign="top">12 (10)</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Other</td><td align="char" char="." valign="top">8 (7)</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Unknown</td><td align="char" char="." valign="top">3 (3)</td></tr><tr><td align="left" valign="top">Bed partner, n (%)</td><td align="left" valign="top"/></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Yes</td><td align="char" char="." valign="top">64 (55)</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>No</td><td align="char" char="." valign="top">52 (45)</td></tr><tr><td align="left" valign="top">Sensors disturbance (due to PSG<sup><xref ref-type="table-fn" rid="table1fn8">h</xref></sup> device), n (%)</td><td align="left" valign="top"/></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Yes</td><td align="char" char="." valign="top">46 (39)</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>No</td><td align="char" char="." valign="top">71 (61)</td></tr></tbody></table><table-wrap-foot><fn id="table1fn1"><p><sup>a</sup>Skin type is based on the reduced Fitzpatrick scale.</p></fn><fn id="table1fn2"><p><sup>b</sup>Arterial hypertension, atrial fibrillation, or myocardial infarction.</p></fn><fn id="table1fn3"><p><sup>c</sup>Parkinson, stroke, adenoma, manic-depression, or epilepsy.</p></fn><fn id="table1fn4"><p><sup>d</sup>Hemolytic anemia due to glutathione reductase deficiency, ulcer, sleeve, or diverticula.</p></fn><fn id="table1fn5"><p><sup>e</sup>Diabetes, hypothyroidism, dyslipidemia, or obesity/overweight.</p></fn><fn id="table1fn6"><p><sup>f</sup>Depression, insomnia, or anxiety.</p></fn><fn id="table1fn7"><p><sup>g</sup>PSQI: Pittsburgh Sleep Quality Index.</p></fn><fn id="table1fn8"><p><sup>h</sup>PSG: polysomnography.</p></fn></table-wrap-foot></table-wrap><p>A total of 117, mostly healthy, participants were included in the analysis. The cohort comprised 59% (n=69) women and 41% (n=48) men, with a mean age of 39.9 (SD 11.4) years, ranging from 19 to 69 years. The average BMI was 23.9 (SD 3.3) kg/m&#x00B2;.</p><p>The average sleep quality in this population is considered mildly impaired, with a mean PSQI score of 6 out of 21. The SD of 2.9 highlights significant variability.</p><p>The most common mattress types were foam (n=41, 35%), spring (n=29, 25%), and latex (n=24, 21%). Around 55% (n=64) of participants reported having a bed partner. Sensor disturbances were reported by 46 (39%) participants due to the PSG device, while no disturbances were reported regarding the WSA nearable.</p></sec><sec id="s3-2"><title>Sleep Stages Classification</title><p><xref ref-type="fig" rid="figure3">Figure 3</xref> presents the confusion matrix containing the epochs across all nights, and <xref ref-type="table" rid="table2">Table 2</xref> gathers sleep stages classification results on the whole dataset.</p><fig position="float" id="figure3"><label>Figure 3.</label><caption><p>Sleep stage classification confusion matrix (N=117). (Left) Raw confusion matrix displaying total epoch counts for WSA sleep stage detection versus PSG ground truth. (Right) Row-normalized confusion matrix (expressed in percentages) illustrating the classification sensitivity and misclassification rates for each true sleep stage. PSG: polysomnography; REM: rapid eye movement (sleep stage); WSA: Withings Sleep Analyzer.</p></caption><graphic alt-version="no" mimetype="image" position="float" xlink:type="simple" xlink:href="humanfactors_v13i1e77033_fig03.png"/></fig><table-wrap id="t2" position="float"><label>Table 2.</label><caption><p>Summary of sleep stage classification results over nights (N=117) (computed as the averages of all nights).</p></caption><table id="table2" frame="hsides" rules="groups"><thead><tr><td align="left" valign="bottom">Mean of results per night</td><td align="left" valign="bottom" colspan="8">Sleep stages</td><td align="left" valign="bottom" colspan="4">Sleep-wake</td></tr><tr><td align="left" valign="bottom"/><td align="left" valign="bottom">Kappa</td><td align="left" valign="bottom">Accuracy</td><td align="left" valign="bottom">Se<sup><xref ref-type="table-fn" rid="table2fn1">a</xref></sup> REM<sup><xref ref-type="table-fn" rid="table2fn2">b</xref></sup></td><td align="left" valign="bottom">Se light</td><td align="left" valign="bottom">Se deep</td><td align="left" valign="bottom">Sp<sup><xref ref-type="table-fn" rid="table2fn3">c</xref></sup> REM</td><td align="left" valign="bottom">Sp light</td><td align="left" valign="bottom">Sp deep</td><td align="left" valign="bottom">Kappa</td><td align="left" valign="bottom">Accuracy</td><td align="left" valign="bottom">Se sleep</td><td align="left" valign="bottom">Sp sleep</td></tr></thead><tbody><tr><td align="left" valign="top">Mean</td><td align="left" valign="top">0.49</td><td align="left" valign="top">0.63</td><td align="left" valign="top">0.53</td><td align="left" valign="top">0.68</td><td align="left" valign="top">0.56</td><td align="left" valign="top">0.93</td><td align="left" valign="top">0.69</td><td align="left" valign="top">0.94</td><td align="left" valign="top">0.65</td><td align="left" valign="top">0.87</td><td align="left" valign="top">0.93</td><td align="left" valign="top">0.73</td></tr><tr><td align="char" char="." valign="top">95% CI</td><td align="left" valign="top">0.47-0.51</td><td align="left" valign="top">0.62-0.65</td><td align="left" valign="top">0.48-0.57</td><td align="left" valign="top">0.65-0.71</td><td align="left" valign="top">0.51-0.60</td><td align="left" valign="top">0.92-0.94</td><td align="left" valign="top">0.67-0.71</td><td align="left" valign="top">0.93-0.95</td><td align="left" valign="top">0.62-0.69</td><td align="left" valign="top">0.86-0.89</td><td align="left" valign="top">0.92-0.94</td><td align="left" valign="top">0.69-0.77</td></tr><tr><td align="left" valign="top">SD</td><td align="left" valign="top">0.12</td><td align="left" valign="top">0.09</td><td align="left" valign="top">0.24</td><td align="left" valign="top">0.16</td><td align="left" valign="top">0.25</td><td align="left" valign="top">0.05</td><td align="left" valign="top">0.11</td><td align="left" valign="top">0.06</td><td align="left" valign="top">0.19</td><td align="left" valign="top">0.07</td><td align="left" valign="top">0.06</td><td align="left" valign="top">0.22</td></tr></tbody></table><table-wrap-foot><fn id="table2fn1"><p><sup>a</sup>Se: sensitivity. </p></fn><fn id="table2fn2"><p><sup>b</sup>REM: rapid eye movement (sleep stage).</p></fn><fn id="table2fn3"><p><sup>c</sup>Sp: specificity. </p></fn></table-wrap-foot></table-wrap><sec id="s3-2-1"><title>Sensitivity and Specificity</title><p>The WSA sensitivity for detecting sleep was 93% (95% CI 92%-94%; N=117), meaning it correctly identifies when a person is asleep 93% of the time. The mean specificity was 73% (95% CI 69%-77%), indicating it accurately detects when a person is awake 73% of the time.</p><p>The performance in accurately classifying each individual sleep stage against the other three is more variable, with sensitivities of 53% (95% CI 48%-57%), 68% (95% CI 65%-71%), 56% (95% CI 51%-60%), and 73% (95% CI 69%-77%) for REM, light sleep, deep sleep, and wake stage, respectively. The corresponding specificities were 93% (95% CI 92%-94%), 69% (95% CI 67%-71%), 94% (95% CI 93%-95%), and 93% (95% CI 92%-94%), respectively.</p></sec><sec id="s3-2-2"><title>Cohen &#x03BA; and Accuracy</title><p>Please note that, contrary to sensitivity and specificity, Cohen &#x03BA; and accuracy depend on the relative sizes (prevalences) of each class. In this study&#x2019;s dataset, the WSA mean Cohen &#x03BA; was 0.65 (95% CI 62%-69%) for distinguishing between sleep and wake stages, and 0.49 (95% CI 47%-51%) for differentiating among the 4 stages (N=117). WSA accuracy to distinguish between sleep and wake was 87% (95% CI 86%-89%). The mean accuracy for the 4 stages was 63% (95% CI 62%-65%).</p></sec></sec><sec id="s3-3"><title>Assessment of Sleep Quantity Measures</title><p><xref ref-type="fig" rid="figure4">Figure 4</xref> shows the TST estimated by the WSA versus the PSG. The slope of the linear regression is 0.98 (<italic>P</italic>&#x003C;.001) and the <italic>R</italic><sup>2</sup> value is 0.89, with 38% of outliers, indicating a moderate linear relationship with PSG.</p><fig position="float" id="figure4"><label>Figure 4.</label><caption><p>RANSAC regression plot between WSA and PSG total sleep time (black line) compared to the identity line (red dashed line) on 117 participants (<italic>R</italic><sup>2</sup>=0.89, slope <italic>P</italic> value <italic>P</italic> &#x003C; .001, inliers: 62%). PSG: polysomnography; RANSAC: random sample consensus algorithm; TST: total sleep time; WSA: Withings Sleep Analyzer.</p></caption><graphic alt-version="no" mimetype="image" position="float" xlink:type="simple" xlink:href="humanfactors_v13i1e77033_fig04.png"/></fig><p>WSA deep sleep was not correlated to time spent in deep sleep (slope estimate of 0.05, <italic>P</italic>=.7, Figure S4 in <xref ref-type="supplementary-material" rid="app1">Multimedia Appendix 1</xref>). The WSA estimates of light sleep and REM were moderately correlated with PSG values, with respective slopes of the regression lines of 0.4 (<italic>P</italic>&#x003C;.001, Figure S5 in <xref ref-type="supplementary-material" rid="app1">Multimedia Appendix 1</xref>) and 0.65 (<italic>P</italic>&#x003C;.001, Figure S6 in <xref ref-type="supplementary-material" rid="app1">Multimedia Appendix 1</xref>).</p><p>Precision of the WSA estimates is measured with the MAE. The MAE values of total sleep time (equal to the MAE of wake duration because the sum of TST and wake duration is the recording time), REM duration, light sleep duration, and deep sleep duration are 44 min, 35 min, 1 h 33 min, and 1 h 4 min, respectively, with average PSG values of 7 h 15 min (3 h 03 min for awake duration), 1 h 43 min, 2 h 57 min, and 2 h 35 min, respectively. Corresponding 95% CIs are reported in <xref ref-type="table" rid="table3">Table 3</xref>. The average number of episodes in each sleep stage and the average number of stage changes can be found in <xref ref-type="table" rid="table4">Table 4</xref>. The WSA tends to underestimate the number of episodes for each sleep stage and is less sensitive to transitions between epochs.</p><table-wrap id="t3" position="float"><label>Table 3.</label><caption><p>Summary of Bland-Altman results obtained on sleep-related metrics between WSA<sup><xref ref-type="table-fn" rid="table3fn1">a</xref></sup> and PSG<sup><xref ref-type="table-fn" rid="table3fn2">b</xref></sup> estimations (N=117).</p></caption><table id="table3" frame="hsides" rules="groups"><thead><tr><td align="left" valign="top">Sleep quality measures</td><td align="left" valign="top">PSG value, mean (SD)</td><td align="left" valign="top">MAE<sup><xref ref-type="table-fn" rid="table3fn3">c</xref></sup> (95% CI)</td><td align="left" valign="top">Bias, WSA &#x2013; PSG (95% CI)</td></tr></thead><tbody><tr><td align="left" valign="top">TST<sup><xref ref-type="table-fn" rid="table3fn4">d</xref></sup></td><td align="left" valign="top">7 h 15 min (1 h 14 min)</td><td align="left" valign="top">44 min (36 min to 52 min)</td><td align="left" valign="top">20 min (10 min to 31 min)</td></tr><tr><td align="left" valign="top">TIREM<sup><xref ref-type="table-fn" rid="table3fn5">e</xref></sup></td><td align="left" valign="top">1 h 43 min (45 min)</td><td align="left" valign="top">35 min (30 min to 40 min)</td><td align="left" valign="top">&#x2013;15 min (&#x2013;23 min to &#x2013;8 min)</td></tr><tr><td align="left" valign="top">TILight<sup><xref ref-type="table-fn" rid="table3fn6">f</xref></sup></td><td align="left" valign="top">2 h 57 min (1 h 12 min)</td><td align="left" valign="top">1 h 32 min (1 h 21 min to 1 h 44 min)</td><td align="left" valign="top">1 h 21 min (1 h 8 min to 1 h 36 min)</td></tr><tr><td align="left" valign="top">TIDeep<sup><xref ref-type="table-fn" rid="table3fn7">g</xref></sup></td><td align="left" valign="top">2 h 35 min (54 min)</td><td align="left" valign="top">1 h 4 min (55 min to 1 h 13 min)</td><td align="left" valign="top">&#x2013;46 min (&#x2013;59 min to &#x2013;34 min)</td></tr><tr><td align="left" valign="top">TIWake<sup><xref ref-type="table-fn" rid="table3fn8">h</xref></sup></td><td align="left" valign="top">3 h 3 min (1 h 19 min)</td><td align="left" valign="top">44 min (36 min to 52 min)</td><td align="left" valign="top">&#x2013;20 min (&#x2013;31 min to &#x2013;10 min)</td></tr><tr><td align="left" valign="top">PIREM<sup><xref ref-type="table-fn" rid="table3fn9">i</xref></sup></td><td align="char" char="." valign="top">17% (8.8%)</td><td align="char" char="." valign="top">5.7% (4.9% to 6.5%)</td><td align="char" char="." valign="top">&#x2013;2.4% (&#x2013;3.6% to &#x2013;1.1%)</td></tr><tr><td align="left" valign="top">PILight<sup><xref ref-type="table-fn" rid="table3fn10">j</xref></sup></td><td align="char" char="." valign="top">29% (14%)</td><td align="char" char="." valign="top">15% (13% to 17%)</td><td align="char" char="." valign="top">13% (11% to 15%)</td></tr><tr><td align="left" valign="top">PIDeep<sup><xref ref-type="table-fn" rid="table3fn11">k</xref></sup></td><td align="char" char="." valign="top">25% (11%)</td><td align="char" char="." valign="top">10% (8.8% to 12%)</td><td align="char" char="." valign="top">&#x2013;7.4% (&#x2013;9.4% to &#x2013;5.4%)</td></tr><tr><td align="left" valign="top">PIWake<sup><xref ref-type="table-fn" rid="table3fn12">l</xref></sup></td><td align="char" char="." valign="top">29% (11%)</td><td align="char" char="." valign="top">7.1% (5.8% to 8.4%)</td><td align="char" char="." valign="top">&#x2013;3.3% (&#x2013;5.0% to &#x2013;1.6%)</td></tr></tbody></table><table-wrap-foot><fn id="table3fn1"><p><sup>a</sup>WSA: Withings Sleep Analyzer.</p></fn><fn id="table3fn2"><p><sup>b</sup>PSG: polysomnography.</p></fn><fn id="table3fn3"><p><sup>c</sup>MAE: mean absolute error.</p></fn><fn id="table3fn4"><p><sup>d</sup>TST: total sleep time.</p></fn><fn id="table3fn5"><p><sup>e</sup>TIREM: time spent in rapid eye movement sleep stage.</p></fn><fn id="table3fn6"><p><sup>f</sup>TILight: time spent in light sleep stage.</p></fn><fn id="table3fn7"><p><sup>g</sup>TIDeep: time spent in deep sleep stage.</p></fn><fn id="table3fn8"><p><sup>h</sup>TIWake: time spent in wake stage.</p></fn><fn id="table3fn9"><p><sup>i</sup>PIREM: proportion of the night in rapid eye movement sleep stage.</p></fn><fn id="table3fn10"><p><sup>j</sup>PILight: proportion of the night in light sleep stage.</p></fn><fn id="table3fn11"><p><sup>k</sup>PIDeep: proportion of the night in deep sleep stage.</p></fn><fn id="table3fn12"><p><sup>l</sup>PIWake: proportion of the night in wake stage.</p></fn></table-wrap-foot></table-wrap><table-wrap id="t4" position="float"><label>Table 4.</label><caption><p>Comparison of the number of sleep stage episodes and stage changes between WSA<sup><xref ref-type="table-fn" rid="table4fn1">a</xref></sup> and PSG<sup><xref ref-type="table-fn" rid="table4fn2">b</xref></sup> (N=117).</p></caption><table id="table4" frame="hsides" rules="groups"><thead><tr><td align="left" valign="bottom">Sleep quality measure</td><td align="left" valign="bottom">Episodes<sup><xref ref-type="table-fn" rid="table4fn3">c</xref></sup> of REM<sup><xref ref-type="table-fn" rid="table4fn4">d</xref></sup></td><td align="left" valign="bottom">Episodes<sup><xref ref-type="table-fn" rid="table4fn3">c</xref></sup> of light</td><td align="left" valign="bottom">Episodes<sup><xref ref-type="table-fn" rid="table4fn3">c</xref></sup> of deep</td><td align="left" valign="bottom">Episodes<sup><xref ref-type="table-fn" rid="table4fn3">c</xref></sup> of wake</td><td align="left" valign="bottom">Stage changes</td></tr></thead><tbody><tr><td align="left" valign="top">WSA, mean (95% CI)</td><td align="left" valign="top">4.1 (3.8-4.5)</td><td align="left" valign="top">8.9 (8.4-9.3)</td><td align="left" valign="top">4.4 (4.0-4.7)</td><td align="left" valign="top">4.4 (4.1-4.8)</td><td align="left" valign="top">8.9 (8.4-9.3)</td></tr><tr><td align="left" valign="top">PSG, mean (95% CI)</td><td align="left" valign="top">5.0 (4.7-5.3)</td><td align="left" valign="top">13.2 (12.7-13.8)</td><td align="left" valign="top">7.1 (6.7-7.6)</td><td align="left" valign="top">4.9 (4.5-5.4)</td><td align="left" valign="top">13.2 (12.7-13.8)</td></tr></tbody></table><table-wrap-foot><fn id="table4fn1"><p><sup>a</sup>WSA: Withings Sleep Analyzer.</p></fn><fn id="table4fn2"><p><sup>b</sup>PSG: polysomnography.</p></fn><fn id="table4fn3"><p><sup>c</sup>An episode is a sequence of consecutive epochs in the same sleep stage.</p></fn><fn id="table4fn4"><p><sup>d</sup>REM: rapid eye movement (sleep stage).</p></fn></table-wrap-foot></table-wrap><p>Additional scatter plots and regression analyses of these metrics can be found in Section D of <xref ref-type="supplementary-material" rid="app1">Multimedia Appendix 1</xref>.</p><p>The Bland-Altman plots are presented in <xref ref-type="fig" rid="figure5">Figures 5</xref> and <xref ref-type="fig" rid="figure6">6</xref>. Biases are summarized in <xref ref-type="table" rid="table3">Table 3</xref>.</p><fig position="float" id="figure5"><label>Figure 5.</label><caption><p>Bland-Altman plot comparing WSA and PSG estimation of total sleep time and time in REM on 117 participants. LOA: limits of agreement; PSG: polysomnography; REM: rapid eye movement (sleep stage); TIREM: time spent in rapid eye movement sleep stage; TST: total sleep time; WSA: Withings Sleep Analyzer.</p></caption><graphic alt-version="no" mimetype="image" position="float" xlink:type="simple" xlink:href="humanfactors_v13i1e77033_fig05.png"/></fig><fig position="float" id="figure6"><label>Figure 6.</label><caption><p>Bland-Altman plot comparing WSA and PSG estimation of time in deep and time in light (N=117). LOA: limits of agreement; PSG: polysomnography; TIDeep: time spent in deep sleep stage; TILight: time spent in light sleep stage; WSA: Withings Sleep Analyzer.</p></caption><graphic alt-version="no" mimetype="image" position="float" xlink:type="simple" xlink:href="humanfactors_v13i1e77033_fig06.png"/></fig><p>In <xref ref-type="fig" rid="figure5">Figure 5</xref>, the Bland-Altman plot for TST does not reveal any proportional bias with the duration of the night. The mean error is 20 minutes. The wide limits of agreement show that there is a substantial amount of variability between PSG and WSA. By contrast, the average error in REM, light, and deep sleep durations depends on the duration of the phase, therefore exhibiting proportional bias. Light sleep is <italic>on average</italic> overestimated for any duration, deep sleep is <italic>on average</italic> underestimated for any duration, and REM is <italic>on average</italic> underestimated for short durations and overestimated for long durations.</p><p>The mean error (bias) in light sleep duration is important, with 1 h 21 min. Biases in REM and deep sleep are &#x2212;15 min and &#x2212;46 min, respectively. The mean error in TST is therefore 20 min.</p></sec><sec id="s3-4"><title>Subgroup Analyses</title><p>No significant differences were found in the median or variance of the error across most groups for all the quantitative sleep variables of <xref ref-type="table" rid="table3">Table 3</xref>. This includes comparisons based on gender, BMI categories, age groups, sleeping arrangements, PSQI scores, self-reported sleep quality, mattress thickness, and night awakenings. However, significant differences in median total sleep time and wakefulness proportion were observed within the PSQI sleep duration component subgroup. Median MAE of TST is respectively 21 min and 1 h 11 min for good and bad sleep duration subgroups, and median MAE of wakefulness proportion is respectively 3% and 12% for good and bad sleep duration subgroups (N=117). This finding suggests that distinguishing sleep from wake is a harder task for the WSA when the participant has subjective short sleep duration (&#x003C;6 h), highlighting an area for further investigation. For a comprehensive overview of the statistical tests and detailed results, please refer to <xref ref-type="supplementary-material" rid="app2">Multimedia Appendix 2</xref>.</p><p>As an illustration, <xref ref-type="fig" rid="figure7">Figures 7</xref><xref ref-type="fig" rid="figure8"/>-<xref ref-type="fig" rid="figure9">9</xref> show the boxplots of TST MAE of WSA compared to PSG, stratified by age groups, BMI ranges, and whether the participant was alone in bed. They suggest that the WSA performance did not depend on these factors. Boxplots for TST MAE for the other subgroups can be found in Section D of <xref ref-type="supplementary-material" rid="app1">Multimedia Appendix 1</xref>.</p><fig position="float" id="figure7"><label>Figure 7.</label><caption><p>Boxplot of TST mean AE (hours) by age group (N=117). AE: absolute error; TST: total sleep time.</p></caption><graphic alt-version="no" mimetype="image" position="float" xlink:type="simple" xlink:href="humanfactors_v13i1e77033_fig07.png"/></fig><fig position="float" id="figure8"><label>Figure 8.</label><caption><p>Boxplot of total sleep time mean AE (hours) by BMI group (N=117). AE: absolute error; TST: total sleep time.</p></caption><graphic alt-version="no" mimetype="image" position="float" xlink:type="simple" xlink:href="humanfactors_v13i1e77033_fig08.png"/></fig><fig position="float" id="figure9"><label>Figure 9.</label><caption><p>Boxplot of total sleep time mean AE (hours) by <italic>is couple</italic> group (N=117). No: participants who slept alone the night of the recording; yes: participants who had a sleep partner the night of the recording. AE: absolute error; TST: total sleep time.</p></caption><graphic alt-version="no" mimetype="image" position="float" xlink:type="simple" xlink:href="humanfactors_v13i1e77033_fig09.png"/></fig></sec><sec id="s3-5"><title>Agreement Between Reviewers</title><p>Each 30-second epoch of the PSG data was independently annotated by two reviewers. The mean &#x03BA; value for sleep stage determination between reviewers before reaching consensus is 0.71 (SD 0.11), closely aligning with literature findings (&#x03BA;=0.76 in [<xref ref-type="bibr" rid="ref53">53</xref>]), while it is 0.81 (SD 0.17) for sleep-wake classification.</p><p>In the analysis of reviewer agreement on sleep stage classifications, the primary disagreements occur between light and deep stages, as well as between light sleep and awake/REM stages (<xref ref-type="fig" rid="figure10">Figure 10</xref>). This indicates that even expert reviewers, considered the gold standard, face challenges in accurately distinguishing these stages due to their inherent similarities and subtle physiological differences. This inherent difficulty in distinguishing light, deep, awake, and REM sleep stages by human experts is reflected in WSA, which was trained on PSG data labeled using a similar protocol. It is likely that the imprecision of the gold standard is passed on to the device.</p><fig position="float" id="figure10"><label>Figure 10.</label><caption><p>Sleep stage classification confusion matrix between the first two reviewers&#x2019; annotations (N=117). REM: rapid eye movement (sleep stage).</p></caption><graphic alt-version="no" mimetype="image" position="float" xlink:type="simple" xlink:href="humanfactors_v13i1e77033_fig10.png"/></fig><sec id="s3-5-1"><title>Discrepancies in Performance: Epochs With Reviewers&#x2019; Agreement vs Disagreement</title><p>Given the discrepancies encountered in PSG annotation among reviewers, it is pertinent to investigate whether the WSA performed better on epochs where reviewers reached consensus compared to those where disagreements were present. To perform this analysis, the dataset was divided into two groups of epochs: those where reviewers reached agreement and those where disagreements occurred. Separate performance analyses were then conducted on these two complementary groups.</p><p>Results are summarized in <xref ref-type="table" rid="table5">Table 5</xref>. In the &#x201C;agreement&#x201D; column (resp. &#x201C;disagreement&#x201D; column), only epochs where both reviewers agreed (resp. disagreed) were included, while epochs with disagreement (resp. agreement) were excluded. <xref ref-type="fig" rid="figure11">Figure 11</xref> shows the confusion matrices obtained for both sets.</p><table-wrap id="t5" position="float"><label>Table 5.</label><caption><p>Summary of performance in reviewers&#x2019; agreement and disagreement subgroups (N=117).</p></caption><table id="table5" frame="hsides" rules="groups"><thead><tr><td align="left" valign="top">WSA<sup><xref ref-type="table-fn" rid="table5fn1">a</xref></sup> vs PSG<sup><xref ref-type="table-fn" rid="table5fn2">b</xref></sup></td><td align="left" valign="top">Agreement</td><td align="left" valign="top">Disagreement</td><td align="left" valign="top"><italic>z</italic> score</td></tr></thead><tbody><tr><td align="left" valign="top">Sleep stages</td><td align="left" valign="top"/><td align="left" valign="top"/><td align="left" valign="top"/></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Epochs, n (%)</td><td align="char" char="." valign="top">113,364 (79)</td><td align="char" char="." valign="top">30,875 (21)</td><td align="left" valign="top">&#x2014;<sup><xref ref-type="table-fn" rid="table5fn3">c</xref></sup></td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Kappa, mean (95% CI)</td><td align="char" char="." valign="top">0.52 (0.50&#x2010;0.55)</td><td align="char" char="." valign="top">0.27 (0.24&#x2010;0.30)</td><td align="char" char="." valign="top">78.06</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Accuracy, mean% (95% CI)</td><td align="char" char="." valign="top">0.66 (0.64&#x2010;0.68)</td><td align="char" char="." valign="top">0.53 (0.50&#x2010;0.55)</td><td align="char" char="." valign="top">42.00</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Se<sup><xref ref-type="table-fn" rid="table5fn4">d</xref></sup> REM<sup><xref ref-type="table-fn" rid="table5fn5">e</xref></sup>, mean (95% CI)</td><td align="char" char="." valign="top">0.55 (0.50&#x2010;0.59)</td><td align="char" char="." valign="top">0.44 (0.39&#x2010;0.49)</td><td align="char" char="." valign="top">34.32</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Se light, mean (95% CI)</td><td align="char" char="." valign="top">0.7 (0.67&#x2010;0.72)</td><td align="char" char="." valign="top">0.64 (0.60&#x2010;0.67)</td><td align="char" char="." valign="top">20.16</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Se deep, mean (95% CI)</td><td align="char" char="." valign="top">0.56 (0.51&#x2010;0.60)</td><td align="char" char="." valign="top">0.37 (0.32&#x2010;0.43)</td><td align="char" char="." valign="top">68.80</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Se wake, mean (95% CI)</td><td align="char" char="." valign="top">0.72 (0.67&#x2010;0.76)</td><td align="char" char="." valign="top">0.51 (0.44&#x2010;0.58)</td><td align="char" char="." valign="top">69.85</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Sp<sup><xref ref-type="table-fn" rid="table5fn6">f</xref></sup> REM, mean (95% CI)</td><td align="char" char="." valign="top">0.94 (0.93&#x2010;0.95)</td><td align="char" char="." valign="top">0.92 (0.90&#x2010;0.93)</td><td align="char" char="." valign="top">12.70</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Sp light, mean (95% CI)</td><td align="char" char="." valign="top">0.72 (0.69&#x2010;0.74)</td><td align="char" char="." valign="top">0.52 (0.48&#x2010;0.56)</td><td align="char" char="." valign="top">66.63</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Sp deep, mean (95% CI)</td><td align="char" char="." valign="top">0.95 (0.94&#x2010;0.96)</td><td align="char" char="." valign="top">0.92 (0.90&#x2010;0.94)</td><td align="char" char="." valign="top">20.25</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Sp wake, mean (95% CI)</td><td align="char" char="." valign="top">0.94 (0.93&#x2010;0.95)</td><td align="char" char="." valign="top">0.92 (0.90&#x2010;0.93)</td><td align="char" char="." valign="top">12.70</td></tr><tr><td align="left" valign="top">Sleep-wake</td><td align="left" valign="top"/><td align="left" valign="top"/><td align="left" valign="top"/></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Epochs, n (%)</td><td align="char" char="." valign="top">133,447 (93)</td><td align="char" char="." valign="top">10,792 (7)</td><td align="left" valign="top">&#x2014;</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Kappa, mean (95% CI)</td><td align="char" char="." valign="top">0.64 (0.59&#x2010;0.68)</td><td align="char" char="." valign="top">0.33 (0.26&#x2010;0.38)</td><td align="char" char="." valign="top">63.72</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Accuracy, mean% (95% CI)</td><td align="char" char="." valign="top">0.88 (0.86&#x2010;0.89)</td><td align="char" char="." valign="top">0.76 (0.71&#x2010;0.78)</td><td align="char" char="." valign="top">35.77</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Se wake, mean (95% CI)</td><td align="char" char="." valign="top">0.74 (0.67&#x2010;0.76)</td><td align="char" char="." valign="top">0.52 (0.46&#x2010;0.59)</td><td align="char" char="." valign="top">49.15</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Se sleep, mean (95% CI)</td><td align="char" char="." valign="top">0.94 (0.93&#x2010;0.95)</td><td align="char" char="." valign="top">0.86 (0.83&#x2010;0.89)</td><td align="char" char="." valign="top">32.20</td></tr></tbody></table><table-wrap-foot><fn id="table5fn1"><p><sup>a</sup>WSA: Withings Sleep Analyzer.</p></fn><fn id="table5fn2"><p><sup>b</sup>PSG: polysomnography.</p></fn><fn id="table5fn3"><p><sup>c</sup>Not applicable.</p></fn><fn id="table5fn4"><p><sup>d</sup>Se: sensitivity. </p></fn><fn id="table5fn5"><p><sup>e</sup>REM: rapid eye movement (sleep stage).</p></fn><fn id="table5fn6"><p><sup>f</sup>Sp: specificity. </p></fn></table-wrap-foot></table-wrap><fig position="float" id="figure11"><label>Figure 11.</label><caption><p>Sleep stage classification confusion matrices (N=117) on sets with agreement (left) and disagreement (right); WSA sleep stage detection vs PSG ground truth. PSG: polysomnography; REM: rapid eye movement (sleep stage); WSA: Withings Sleep Analyzer.</p></caption><graphic alt-version="no" mimetype="image" position="float" xlink:type="simple" xlink:href="humanfactors_v13i1e77033_fig11.png"/></fig><p>We used a <italic>z</italic> test for proportions to test for differences between sensitivity, specificity, accuracy, and kappa. All the results are statistically significant, with WSA performing better on epochs where the two reviewers agreed. The progression is particularly significant for the sensitivity in deep sleep, reaching 0.56, compared to 0.37 when the reviewers disagreed, as in the latter case, WSA predominantly classified deep sleep stages as light sleep. The specificity for light sleep was also starkly improved from 0.52 to 0.72. As a result, the Cohen &#x03BA; is almost double when reviewers agreed (0.64 vs 0.33 for S/W classification, and 0.52 vs 0.27 for 4-stage classification).</p></sec></sec><sec id="s3-6"><title>Sleep Quality With vs Without PSG</title><p>Since this analysis does not involve the WSA or the PSG data, but only the participants&#x2019; answers to the questionnaires, it was conducted on the 186 participants for whom reported sleep quality data were available. Results are given in <xref ref-type="table" rid="table6">Table 6</xref>.</p><table-wrap id="t6" position="float"><label>Table 6.</label><caption><p>Comparison of reported sleep quality and sensor disturbance with and without PSG<sup><xref ref-type="table-fn" rid="table6fn1">a</xref></sup> (n=186). In both cases, the participant used a WSA<sup><xref ref-type="table-fn" rid="table6fn2">b</xref></sup> and two ScanWatch devices.</p></caption><table id="table6" frame="hsides" rules="groups"><thead><tr><td align="left" valign="top">Qualitative sleep quality measures</td><td align="left" valign="top">First night with PSG</td><td align="left" valign="top">Second night without PSG</td></tr></thead><tbody><tr><td align="left" valign="top">Sleep quality, n (%)</td><td align="left" valign="top"/><td align="left" valign="top"/></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Very poor</td><td align="char" char="." valign="top">10 (5.4)</td><td align="char" char="." valign="top">3 (1.6)</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Poor</td><td align="char" char="." valign="top">65 (34.9)</td><td align="char" char="." valign="top">32 (17.2)</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Quite good</td><td align="char" char="." valign="top">75 (40.3)</td><td align="char" char="." valign="top">71 (38.2)</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Good</td><td align="char" char="." valign="top">32 (17.2)</td><td align="char" char="." valign="top">58 (31.2)</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Very good</td><td align="char" char="." valign="top">4 (2.2)</td><td align="char" char="." valign="top">22 (11.8)</td></tr><tr><td align="left" valign="top">Sleep quality compared to usual sleep quality, n (%)</td><td align="left" valign="top"/><td align="left" valign="top"/></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Much worse</td><td align="char" char="." valign="top">28 (15.1)</td><td align="char" char="." valign="top">6 (3.2)</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Worse</td><td align="char" char="." valign="top">69 (37.1)</td><td align="char" char="." valign="top">32 (17.2)</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Same</td><td align="char" char="." valign="top">77 (41.4)</td><td align="char" char="." valign="top">111 (59.7)</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Better</td><td align="char" char="." valign="top">10 (5.4)</td><td align="char" char="." valign="top">31 (16.7)</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Much better</td><td align="char" char="." valign="top">2 (1.1)</td><td align="char" char="." valign="top">6 (3.2)</td></tr><tr><td align="left" valign="top">Sensor disturbance</td><td align="left" valign="top"/><td align="left" valign="top"/></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Device that caused sleep disturbances</td><td align="left" valign="top">PSG</td><td align="left" valign="top">WSA</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Yes, n (%)</td><td align="char" char="." valign="top">77 (41.4)</td><td align="char" char="." valign="top">0 (0)</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>No, n (%)</td><td align="char" char="." valign="top">109 (58.6)</td><td align="char" char="." valign="top">0 (0)</td></tr></tbody></table><table-wrap-foot><fn id="table6fn1"><p><sup>a</sup>PSG: polysomnography.</p></fn><fn id="table6fn2"><p><sup>b</sup>WSA: Withings Sleep Analyzer.</p></fn></table-wrap-foot></table-wrap><p>Despite the removal of the nasal cannula and the blood oximeter from our home PSG test, the sleep test was associated with significant discomfort in 41% (77/186) of the participants during the night of the PSG home test, compared to 0% (0/186) in the subsequent night with the WSA only. Fifty-two percent (97/186) (resp. 20%, 38/186) of the participants reported a degraded sleep quality on the night of the PSG (resp. without the PSG).</p><p><xref ref-type="fig" rid="figure12">Figure 12</xref> illustrates the changes in sleep quality among participants over 2 consecutive nights. Participants generally experienced better sleep without the PSG sensors. Notable improvements were observed in 52% (97/186) of cases, with transitions from fairly good to good (26/186, 14%), and from poor to fairly good (31/186, 17%), good (12/186, 6%), or very good (10/186, 5%). Additionally, some participants reported significant improvements from very poor to very good sleep, and others from poor to fairly good. These improvements may be influenced by several factors, including the removal of PSG sensors, which can be intrusive and uncomfortable, potentially disrupting sleep. Furthermore, the awareness of being recorded might alter participants&#x2019; sleep behavior, either positively or negatively. The use of unfamiliar devices could also play a role, as participants may initially experience discomfort or anxiety, which diminishes over time. External conditions such as noise and room temperature, which were not controlled in this study, could also significantly impact sleep quality. Therefore, while the data suggest improvements, it is crucial to consider these potential confounding factors when interpreting the results.</p><fig position="float" id="figure12"><label>Figure 12.</label><caption><p>Comparison of reported sleep quality with and without PSG (N=186). Green: improved; yellow: identical; red: deteriorated; black: first night with PSG; grey: second night without PSG. In both cases, the participant used a WSA and two ScanWatch devices. PSG: polysomnography; WSA: Withings Sleep Analyzer.</p></caption><graphic alt-version="no" mimetype="image" position="float" xlink:type="simple" xlink:href="humanfactors_v13i1e77033_fig12.png"/></fig><p><xref ref-type="table" rid="table6">Table 6</xref> highlights that participants slept as well with WSA as they typically do. On the second night, 59.7% (111/186) of participants reported the same sleep quality, 16.7% (31/186) reported better sleep, and 3.2% (6/186) reported much better sleep compared to their usual experience. This suggests that Withings sleep monitoring devices do not negatively impact sleep quality and may even enhance it for some users.</p></sec></sec><sec id="s4" sec-type="discussion"><title>Discussion</title><sec id="s4-1"><title>Main Findings</title><p>The evaluation of the WSA for sleep stage detection in a cohort of 117 participants in a home setting revealed several key insights. The device demonstrated a high sensitivity of 93% for detecting sleep, underscoring its strong capability to accurately identify sleep periods. However, the specificity was moderate at 73%. The duration of the recording before actual sleep onset and after wake-up significantly affects observed performance of wake detection, with shorter periods inflating specificity, accuracy, and Cohen &#x03BA;. This occurs due to a shortening of quiet wake periods hard to distinguish from sleep (reading or screen time in bed, for instance), leading to fewer false positives while true negatives remain relatively constant. Conversely, overly long (eg, 24-hour) recordings, dominated by easily identifiable diurnal wakefulness, also tend to inflate specificity. In both cases, the performance of the evaluated device is overestimated. The most clinically relevant and challenging scenario for performance evaluation involves analyzing data encompassing the entire in-bed period, including calm wakefulness before sleep onset and after awakening. While AASM guidelines suggest using lights-off and lights-on as proxies for night boundaries, this approach truncates crucial pre&#x2013; and post&#x2013;sleep wake data, therefore introducing a bias in TST and classification performance endpoints. To mitigate this, we used all available PSG annotations, irrespective of lights-off and lights-on times, to provide a more comprehensive and unbiased assessment of performance across the full in-bed duration.</p><p>The classification of sleep stages (into wake, REM, light, and deep phases) is more challenging. The confusion matrix (<xref ref-type="fig" rid="figure3">Figure 3</xref>) shows that 40% of deep sleep phases, 37% of REM sleep, and 20% of wake phases were misclassified as light sleep by the WSA. As a result, the corresponding sensitivities were rather low (0.56, 0.53, and 0.73, respectively). Thirty-two percent of light sleep stages were misclassified, in similar proportions, into REM, deep sleep, and wake. In consequence, (1) the REM and deep sleep total durations were underestimated (by approximately 30% and 15%), while light sleep duration was overestimated by almost 48% (biases in <xref ref-type="table" rid="table3">Table 3</xref>), and (2) the specificities for wake, REM, and deep sleep are very high (0.93, 0.94, and 0.94, respectively), while the specificity for light sleep is moderate (0.69).</p><p>We showed that these misclassifications of WSA mirror the disagreements between PSG reviewers, who mainly disagree on light versus all the other sleep stages (<xref ref-type="fig" rid="figure11">Figure 11</xref>). WSA classification was indeed significantly better on epochs where reviewers agreed (79% of the epochs) than on epochs where they disagreed. WSA&#x2019;s sleep stage classification uses an algorithm trained by supervised learning on PSG data annotated by technician experts, so it is expected that WSA performance is limited by the interreader variability.</p><p>Consistent with existing validation studies [<xref ref-type="bibr" rid="ref33">33</xref>,<xref ref-type="bibr" rid="ref44">44</xref>], we also report accuracy and Cohen &#x03BA;. We caution that these performance metrics are strongly dependent on the prevalence of the classes (here, wake, sleep, REM, deep, and light), which creates difficulties in comparing results between studies. In particular, for sleep studies, two factors modify the prevalence of the classes significantly. First, there is no standardized definition of the beginning of the night. Second, the choice of the reference device has some importance, causing more or less sleep disturbances.</p><p>With these caveats in mind, the WSA achieved an overall accuracy of 87% for sleep-wake distinction, which is promising for a contactless home monitoring device. Despite this, the accuracy for classifying specific sleep stages was moderate, with REM sleep at 53%, light sleep at 68%, and deep sleep at 56%. The overall accuracy for sleep stage classification was 63%, with a Cohen &#x03BA; of 0.49.</p><p>Notably, the WSA&#x2019;s performance was consistent across various demographic subgroups, including different age and BMI categories. Importantly for a device under the mattress, there was no difference between individuals who slept alone and those with a bed partner, nor between different types or thicknesses of mattresses. Other groups analyzed included sex, PSQI scores, self-reported sleep quality, and whether individuals woke up during the night, all of which also showed no significant differences in MAE, except for wake proportion by subjective sleep duration group. This consistency suggests the device may be useful for a wide range of participants.</p></sec><sec id="s4-2"><title>Comparison With Previous Research</title><sec id="s4-2-1"><title>Differences in Studies&#x2019; Protocols</title><p>To contextualize our findings, we used published validation studies of other consumer sleep trackers. We advise interpreting these comparisons with caution, as study protocols vary significantly (eg, in-lab vs at-home settings, population characteristics, and data handling procedures). We compare our results on WSA with influential studies that have contributed to the understanding of consumer sleep-tracking technology. Studies [<xref ref-type="bibr" rid="ref29">29</xref>], [<xref ref-type="bibr" rid="ref37">37</xref>], and [<xref ref-type="bibr" rid="ref33">33</xref>], respectively, evaluated 7, 5, and 6 consumer devices against PSG, mainly wearable devices, revealing significant variability in their accuracy for sleep stage detection. Studies [<xref ref-type="bibr" rid="ref33">33</xref>,<xref ref-type="bibr" rid="ref54">54</xref>-<xref ref-type="bibr" rid="ref60">60</xref>] compared a total of 8 contact-free devices and 1 wearable against PSG. These studies provide a valuable context for evaluating our device&#x2019;s performance, illustrating both the advancements and challenges in the field of consumer sleep technology. All the data used for this comparison can be found in <xref ref-type="supplementary-material" rid="app3">Multimedia Appendix 3</xref>.</p><p>We compared the performance metrics reported by other studies on their respective datasets to the performance we obtained on our dataset, without reproducing their results or running their device algorithms on our data. When a result was not explicitly provided in the study report, we calculated it from the confusion matrix if it was available.</p><p>Consistent with recent validations [<xref ref-type="bibr" rid="ref39">39</xref>], our study population encompasses a diverse range of cofactors of sleep quality, presenting a wide range of age and BMI, as was the case in only 2 of the 11 studies used for the comparison [<xref ref-type="bibr" rid="ref55">55</xref>,<xref ref-type="bibr" rid="ref59">59</xref>]. Four studies [<xref ref-type="bibr" rid="ref37">37</xref>,<xref ref-type="bibr" rid="ref38">38</xref>,<xref ref-type="bibr" rid="ref44">44</xref>,<xref ref-type="bibr" rid="ref58">58</xref>] included only young adults, and one study focused on older adults [<xref ref-type="bibr" rid="ref33">33</xref>].</p><p>The conditions of our study are not controlled since participants stayed at home, as in only one other study [<xref ref-type="bibr" rid="ref54">54</xref>] but on a much smaller scale (n=20). Our dataset is therefore richer regarding important environmental cofactors of sleep quality, including sleeping arrangements (alone or with a partner), mattress types, ambient temperature, lighting and sound, prebedtime activities (eg, no restriction on caffeine or alcohol consumption, on screen time, no forced sleep regularity), and activities during time in bed (eg, no forced turning off of the lights).</p><p>In addition, some studies use strict exclusion criteria also after data collection [<xref ref-type="bibr" rid="ref38">38</xref>] to ensure data quality and reliability, such as excluding individual nights with a total recording time of less than 7 hours and 50 minutes [<xref ref-type="bibr" rid="ref37">37</xref>].</p><p>Thus, our real-world home setting captures the natural variability in sleep patterns and environmental factors. While this enhances the generalizability of our results, reflecting typical user experiences, it also presents a less favorable scenario for the device, posing additional challenges for accurate sleep stage detection and analysis (for instance, activities in bed like reading or screen time can be confounded by the device as sleep). Consequently, our findings provide a more realistic evaluation of the device&#x2019;s performance in everyday conditions.</p></sec><sec id="s4-2-2"><title>Sleep-Wake Classification</title><p>The choice of a sleep monitoring device requires being informed about the trade-off between sleep and wake identification. This is illustrated in <xref ref-type="fig" rid="figure13">Figure 13</xref>. Devices with high sleep sensitivity (&#x2265;0.98) exhibit low specificity (&#x003C;0.30), as observed with the Garmin Forerunner 245, Emfit QS [<xref ref-type="bibr" rid="ref33">33</xref>], Garmin Vivosmart 3, and Garmin Fenix S5. Conversely, devices achieving higher specificity (&#x2265;0.70), such as the EarlySense [<xref ref-type="bibr" rid="ref54">54</xref>] and WSA, tend to show slightly lower sensitivity (0.90&#x2010;0.95).</p><fig position="float" id="figure13"><label>Figure 13.</label><caption><p>Overview of sleep-wake reported sensitivities from varying validation studies. Indication [0] denotes this study. Note: Direct comparison is limited by differences in study protocols and populations [<xref ref-type="bibr" rid="ref33">33</xref>,<xref ref-type="bibr" rid="ref37">37</xref>,<xref ref-type="bibr" rid="ref44">44</xref>,<xref ref-type="bibr" rid="ref54">54</xref>,<xref ref-type="bibr" rid="ref60">60</xref>]. The exact data points corresponding to the figure are fully detailed in <xref ref-type="supplementary-material" rid="app3">Multimedia Appendix 3</xref>.</p></caption><graphic alt-version="no" mimetype="image" position="float" xlink:type="simple" xlink:href="humanfactors_v13i1e77033_fig13.png"/></fig><p>As explained above, the proportion of wake stages in the dataset before and after sleep onset can significantly impact the sleep/wake endpoints. These studies vary in the proportions of wake epochs, which refer to the total time spent awake divided by the total recording duration of the entire dataset. Specifically, these proportions ranged from 8% to 14% in [<xref ref-type="bibr" rid="ref37">37</xref>], 15% in [<xref ref-type="bibr" rid="ref54">54</xref>], ranged from 20% to 33% in [<xref ref-type="bibr" rid="ref44">44</xref>], and from 34% to 42% in [<xref ref-type="bibr" rid="ref33">33</xref>], compared to 30% in our dataset. This information was unfortunately not available for most of the studies evaluating nearable devices [<xref ref-type="bibr" rid="ref55">55</xref>-<xref ref-type="bibr" rid="ref60">60</xref>]. Lower proportions of wake data can inflate overall accuracies and kappas if sleep epoch classification dominates, as noted in [<xref ref-type="bibr" rid="ref61">61</xref>]. In datasets with a low proportion of wake epochs, overall accuracy and kappa can be misleadingly high due to the dominance of sleep epoch classification, which is better classified than wake epochs as indicated in the previous paragraph.</p></sec><sec id="s4-2-3"><title>Sleep Stages Classification</title><p>The trade-off observed in sleep-wake classification is even more pronounced in sleep stage analysis, where no single device consistently outperforms the others across all stages (<xref ref-type="fig" rid="figure14">Figure 14</xref>). The range of sensitivities is particularly large for REM, from 0.37 to 0.80, and quite large for deep sleep (0.28 to 0.68), even after excluding wearables (0.40 to 0.68). The sensitivities for light sleep detection are more homogeneous, with 12 sensitivities between 0.6 and 0.7. The WSA is in the top tier of devices for deep sleep classification, but midrange for light sleep and REM.</p><fig position="float" id="figure14"><label>Figure 14.</label><caption><p>Overview of sleep stage sensitivities from varying validation studies. Indication [0] denotes this study. Note: Direct comparison is limited by differences in study protocols and populations [<xref ref-type="bibr" rid="ref33">33</xref>,<xref ref-type="bibr" rid="ref37">37</xref>,<xref ref-type="bibr" rid="ref44">44</xref>,<xref ref-type="bibr" rid="ref54">54</xref>,<xref ref-type="bibr" rid="ref55">55</xref>,<xref ref-type="bibr" rid="ref59">59</xref>,<xref ref-type="bibr" rid="ref60">60</xref>].</p></caption><graphic alt-version="no" mimetype="image" position="float" xlink:type="simple" xlink:href="humanfactors_v13i1e77033_fig14.png"/></fig><p>The confusion matrices show that, for all devices, the highest proportion of misclassification for each stage is wrong light sleep detection, which can be explained by the inherent difficulty in distinguishing light from the other sleep stages by human experts, as shown in the Results section.</p></sec><sec id="s4-2-4"><title>Device Comparison Conclusion</title><p>This analysis highlights the necessity of considering a comprehensive set of metrics to accurately evaluate the capabilities of each device. Relying on isolated overall metrics such as accuracy or kappa is insufficient to provide a fair assessment [<xref ref-type="bibr" rid="ref62">62</xref>,<xref ref-type="bibr" rid="ref63">63</xref>]. Every device exhibits relative strengths and weaknesses, and no single device clearly outperforms the others across all tasks. The WSA specifically demonstrates robust performance in sleep-wake distinction, while the precise identification of individual sleep stages remains a more challenging task.</p></sec></sec><sec id="s4-3"><title>Methodological Aspects and Strengths of the Study</title><p>The rapid adoption of new sleep technologies in consumer and clinical settings demands rigorous performance evaluation [<xref ref-type="bibr" rid="ref64">64</xref>]. To improve the reliability and comparability of sleep research, we describe our methodology in detail and with transparency, an approach that is supported by recent guidelines advocating for uniform analysis pipelines [<xref ref-type="bibr" rid="ref41">41</xref>,<xref ref-type="bibr" rid="ref42">42</xref>,<xref ref-type="bibr" rid="ref44">44</xref>]. Our study was designed to resolve methodological issues frequently found in the literature.</p><p>The study&#x2019;s strength lies first in its diverse sample of over 100 participants, who are for the most part healthy and with diverse demographic characteristics. Additionally, the inclusion of relevant factors that may negatively impact the device&#x2019;s performance, like the presence of a bed partner and variations in mattress type and thickness, further enriches the dataset, allowing for a comprehensive evaluation of the device&#x2019;s robustness across different real-life conditions in a healthy population. This allowed us to conduct meaningful subgroup analyses.</p><p>A second strength of the study is the method of PSG analysis. Unlike [<xref ref-type="bibr" rid="ref44">44</xref>,<xref ref-type="bibr" rid="ref55">55</xref>-<xref ref-type="bibr" rid="ref58">58</xref>], which opted for a single reviewer, or two reviewers without consensus as in [<xref ref-type="bibr" rid="ref37">37</xref>], our study is aligned with [<xref ref-type="bibr" rid="ref33">33</xref>,<xref ref-type="bibr" rid="ref38">38</xref>] by implementing a double review process with adjudication by a third reviewer in case of disagreement. This consensus methodology is preferable since it enhances the reliability of the sleep stage classification. In particular, we have shown that reviewers often err by misclassifying light sleep stages, a finding consistent with previous research reporting that the interrater reliabilities for light and deep stages were moderate [<xref ref-type="bibr" rid="ref61">61</xref>]. A reliable assessment of devices&#x2019; performance in sleep stage classification therefore requires a strong methodology to establish the ground truth.</p><p>Third, with a view to limit the participants&#x2019; discomfort, we chose to perform PSG at home with a limited number of sensors, without the nasal cannula and oximeter. This setup reduces the sleep disturbances typically associated with lab-based PSG, allowing for a more natural assessment of sleep patterns. This limited set of sensors is sufficient for the evaluation of TST and sleep stage classification, with the trade-off that sleep onset, time in bed, and wakefulness after sleep onset cannot be assessed. Yet, significant sleep disturbances were reported by the participant during the PSG test, underscoring the challenges of completely undisturbed monitoring even in home environments. Despite this, the study offers a realistic evaluation of the WSA&#x2019;s capabilities under typical sleeping conditions.</p><p>Fourth, we aimed to give a comprehensive report of the device&#x2019;s performance. Collecting epoch-by-epoch data enables a granular examination of sleep patterns, the consistency of measurement errors over time, and thus enables an accurate assessment of the reliability and utility of sleep monitoring devices in real-world settings. We emphasized the need for such comprehensive reporting and the elements of the protocol that may bias the performance estimates. Thus, transparency requires a presentation of the results including all the performance endpoints, each presenting a different facet of the device&#x2019;s performance [<xref ref-type="bibr" rid="ref41">41</xref>-<xref ref-type="bibr" rid="ref43">43</xref>].</p><p>In conclusion, given these methodological strengths, our study provides valuable insights into the WSA sleep stage algorithm&#x2019;s performance in real-world settings.</p></sec><sec id="s4-4"><title>Limitations and Future Work</title><p>Despite our efforts for a solid methodology, the study faced several challenges.</p><sec id="s4-4-1"><title>Challenges in Defining Bedtime and Wake Time in Sleep Studies</title><p>A first challenge is created by the lack of a standardized definition of the start time and end time of a sleep study. As per AASM guidelines [<xref ref-type="bibr" rid="ref50">50</xref>], bedtime and wake time are defined as the &#x201C;lights-off&#x201D; and &#x201C;lights-on,&#x201D; respectively. This is not adapted to studies in real-world settings, where participants often go to bed and engage in activities before attempting to fall asleep. In everyday life, individuals may not turn off the lights immediately upon going to bed, nor do they always intend to sleep right away. Similarly, in the morning, people may not turn on the lights immediately upon awakening, and their actual wake time may not coincide with the &#x201C;lights-on&#x201D; reference. This discrepancy is compounded by the lack of a position sensor, which makes it difficult to accurately determine when a person intends to sleep. In other studies [<xref ref-type="bibr" rid="ref37">37</xref>], start and end times of sleep are determined by the participants themselves, as suggested in standard sleep diaries [<xref ref-type="bibr" rid="ref65">65</xref>], but the precision of this method is poor.</p><p>This lack of standardization is detrimental to the assessment of nearable and wearable devices intended to be used in home settings. Errors in sleep estimation, where wakefulness is mistakenly classified as sleep, are more frequent at the beginning and end of the night. The reason is that many devices, including the WSA, rely heavily on movement detection to distinguish wake from sleep. Thus, wake periods when the participant is immobile and calm in bed, such as when reading or scrolling with a low heart rate, are frequently mistaken as sleep by the device.</p><p>Additionally, the practice of activating the PSG immediately before sleep and deactivating it early prevents the gathering of comprehensive data on a participant&#x2019;s sleep habits. This includes behaviors such as spending extended periods in bed without the intention to sleep. To address this limitation, future studies could extend the duration of PSG recordings to capture activities that occur between the time a person gets into bed and falls asleep, as well as between waking and getting out of bed. This approach would provide a more complete picture of sleep behaviors and enable a thorough evaluation of sleep stage classification algorithms in real-world settings.</p></sec><sec id="s4-4-2"><title>Challenges in Data Collection From a Nearable</title><p>A second challenge in studies with connected devices is data loss. Our study is no exception since nearly 19% of the data were lost, primarily due to the wireless transfer by WSA of a large amount of raw sensor data (250 samples per second). Note that this high rate is not representative of the intended use of the device, which, in its commercial version, only transfers processed data at a low frequency. To mitigate the risk of data loss, Wi-Fi routers paired with the WSA were installed at the participant&#x2019;s home. The routers experienced occasional connectivity problems. Data loss was further exacerbated by issues such as accidental unplugging of the device and improper reconnection without calibration. These technical challenges underscore the difficulties of gathering high-quality, high-frequency data in uncontrolled settings.</p><p>Another factor impacted the accuracy of sleep stage classification; despite receiving instructions from a technician, participants with large beds did not always sleep above the sensor but on the other side of the bed. In such cases, the WSA is not operated optimally, which may have restricted its performance.</p></sec><sec id="s4-4-3"><title>Future Work</title><p>To validate the utility of longitudinal passive data collection, it is essential to demonstrate that errors in sleep quality measures are consistent over time for a given user.</p><p>In addition, our study population only includes healthy participants. There is no data on the performance of the device in special populations that might benefit the most from a longitudinal follow-up.</p><p>Looking ahead, the contactless devices hold significant potential for a wide range of research and clinical applications [<xref ref-type="bibr" rid="ref14">14</xref>,<xref ref-type="bibr" rid="ref64">64</xref>,<xref ref-type="bibr" rid="ref66">66</xref>-<xref ref-type="bibr" rid="ref70">70</xref>]. Their capability to monitor sleep in natural environments [<xref ref-type="bibr" rid="ref68">68</xref>] underscores their versatility and relevance in advancing our understanding of sleep health and its implications.</p></sec></sec><sec id="s4-5"><title>Conclusions</title><p>In this study, we aimed to (1) assess the performance of a contactless device for sleep stage identification against the gold standard PSG, (2) benchmark it against other comparable devices, and (3) better understand the limitations of such devices. Our paper contributes to those, while also laying out important methodological issues.</p><p>This study contributes to the growing body of evidence supporting the utility of nearables for longitudinal sleep monitoring. The WSA&#x2019;s contactless, undermattress design facilitates unobtrusive data collection in free-living conditions and demonstrates sleep-wake detection performance comparable to established consumer devices. While precise sleep stage classification remains a technical challenge, our results highlight the importance of testing on large, diverse, challenging datasets to capture real-world variability. This research underscores the need for standardized performance assessment methodologies to enable reliable comparisons across devices and studies, offering insights for future device design and guidance for utilization, advancing the goal of improved sleep monitoring for the general population [<xref ref-type="bibr" rid="ref71">71</xref>].</p></sec></sec></body><back><ack><p>We would like to acknowledge Paul Edouard and S&#x00E9;bastien Ducrot, both employees of Withings, for their crucial support and technical expertise in the offline run of the algorithm. We are also grateful to two anonymous reviewers and the journal editor for their suggestions and comments, which contributed to improving this manuscript. We declare the use of generative AI in the writing process; according to the GAIDeT taxonomy (2025), proofreading was delegated to the Gemini Pro 2.5 tool under full human supervision.</p></ack><notes><sec><title>Funding</title><p>This study received funding from Withings.</p></sec><sec><title>Data Availability</title><p>The dataset analyzed during this study is not publicly available due to concerns for privacy, ethical, and legal reasons, but queries for data access can be directed to the corresponding author at privacy@withings.com.</p></sec></notes><fn-group><fn fn-type="con"><p>Conceptualization: MAS</p><p>Methodology: MAS (lead), DC (lead), MDG (equal), GDL (equal)</p><p>Software: MAS</p><p>Formal analysis: MAS</p><p>Investigation: MAS</p><p>Data Curation: MAS</p><p>Visualization: MAS</p><p>Writing &#x2013; original draft preparation: MAS</p><p>Supervision: DC (lead), MDG (lead), GDL (lead), PAG (equal), ASI (equal)</p><p>Writing &#x2013; review &#x0026; editing: DC (lead), MDG (equal), GDL (equal), PAG (supporting), ASI (supporting)</p></fn><fn fn-type="conflict"><p>This study received funding from Withings, the manufacturer of the device evaluated in this study. MAS is a PhD student affiliated with Universit&#x00E9; Paris Cit&#x00E9;, Reykjav&#x00ED;k University, and Withings. MDG, GDL, and DC are employees of Withings. PE is a consultant for Withings. Withings employees contributed to all the stages of this study, from conceptualization to manuscript writing. No other competing interests.</p></fn></fn-group><glossary><title>Abbreviations</title><def-list><def-item><term id="abb1">AASM</term><def><p>American Academy of Sleep Medicine</p></def></def-item><def-item><term id="abb2">ECG</term><def><p>electrocardiogram</p></def></def-item><def-item><term id="abb3">EEG</term><def><p>electroencephalogram</p></def></def-item><def-item><term id="abb4">EMG</term><def><p>electromyogram</p></def></def-item><def-item><term id="abb5">EOG</term><def><p>electrooculogram</p></def></def-item><def-item><term id="abb6">MAE</term><def><p>mean absolute error</p></def></def-item><def-item><term id="abb7">MCAR</term><def><p>missing completely at random</p></def></def-item><def-item><term id="abb8">NEDeep</term><def><p>number of episodes in deep sleep stage</p></def></def-item><def-item><term id="abb9">NELight</term><def><p>number of episodes in light sleep stage</p></def></def-item><def-item><term id="abb10">NEREM</term><def><p>number of episodes in REM sleep stage</p></def></def-item><def-item><term id="abb11">NEWake</term><def><p>number of episodes in wake stage</p></def></def-item><def-item><term id="abb12">PIDeep</term><def><p>proportion of the night in deep sleep stage</p></def></def-item><def-item><term id="abb13">PILight</term><def><p>proportion of the night in light sleep stage</p></def></def-item><def-item><term id="abb14">PIREM</term><def><p>proportion of the night in REM sleep stage</p></def></def-item><def-item><term id="abb15">PIWake</term><def><p>proportion of the night in wake stage</p></def></def-item><def-item><term id="abb16">PSG</term><def><p>polysomnography</p></def></def-item><def-item><term id="abb17">PSQI</term><def><p>Pittsburgh Sleep Quality Index</p></def></def-item><def-item><term id="abb18">REM</term><def><p>rapid eye movement (sleep stage)</p></def></def-item><def-item><term id="abb19">TIDeep</term><def><p>time spent in deep sleep stage</p></def></def-item><def-item><term id="abb20">TILight</term><def><p>time spent in light sleep stage</p></def></def-item><def-item><term id="abb21">TIREM</term><def><p>time spent in REM sleep stage</p></def></def-item><def-item><term id="abb22">TIWake</term><def><p>time spent in wake stage</p></def></def-item><def-item><term id="abb23">TST</term><def><p>total sleep time</p></def></def-item><def-item><term id="abb24">WSA</term><def><p>Withings Sleep Analyzer</p></def></def-item></def-list></glossary><ref-list><title>References</title><ref id="ref1"><label>1</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Steptoe</surname><given-names>A</given-names> </name><name name-style="western"><surname>O&#x2019;Donnell</surname><given-names>K</given-names> </name><name name-style="western"><surname>Marmot</surname><given-names>M</given-names> </name><name name-style="western"><surname>Wardle</surname><given-names>J</given-names> </name></person-group><article-title>Positive affect, psychological well-being, and good sleep</article-title><source>J Psychosom Res</source><year>2008</year><month>04</month><volume>64</volume><issue>4</issue><fpage>409</fpage><lpage>415</lpage><pub-id pub-id-type="doi">10.1016/j.jpsychores.2007.11.008</pub-id></nlm-citation></ref><ref id="ref2"><label>2</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>O&#x2019;Leary</surname><given-names>K</given-names> </name><name name-style="western"><surname>Bylsma</surname><given-names>LM</given-names> </name><name name-style="western"><surname>Rottenberg</surname><given-names>J</given-names> </name></person-group><article-title>Why might poor sleep quality lead to depression? A role for emotion regulation</article-title><source>Cogn Emot</source><year>2017</year><month>12</month><volume>31</volume><issue>8</issue><fpage>1698</fpage><lpage>1706</lpage><pub-id pub-id-type="doi">10.1080/02699931.2016.1247035</pub-id><pub-id pub-id-type="medline">27807996</pub-id></nlm-citation></ref><ref id="ref3"><label>3</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Lallukka</surname><given-names>T</given-names> </name><name name-style="western"><surname>Sivertsen</surname><given-names>B</given-names> </name><name name-style="western"><surname>Kronholm</surname><given-names>E</given-names> </name><name name-style="western"><surname>Bin</surname><given-names>YS</given-names> </name><name name-style="western"><surname>&#x00D8;verland</surname><given-names>S</given-names> </name><name name-style="western"><surname>Glozier</surname><given-names>N</given-names> </name></person-group><article-title>Association of sleep duration and sleep quality with the physical, social, and emotional functioning among Australian adults</article-title><source>Sleep Health</source><year>2018</year><month>04</month><volume>4</volume><issue>2</issue><fpage>194</fpage><lpage>200</lpage><pub-id pub-id-type="doi">10.1016/j.sleh.2017.11.006</pub-id></nlm-citation></ref><ref id="ref4"><label>4</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Grandner</surname><given-names>MA</given-names> </name></person-group><article-title>Sleep, health, and society</article-title><source>Sleep Med Clin</source><year>2022</year><month>06</month><volume>17</volume><issue>2</issue><fpage>117</fpage><lpage>139</lpage><pub-id pub-id-type="doi">10.1016/j.jsmc.2022.03.001</pub-id><pub-id pub-id-type="medline">35659068</pub-id></nlm-citation></ref><ref id="ref5"><label>5</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Geoffroy</surname><given-names>PA</given-names> </name><name name-style="western"><surname>Hoertel</surname><given-names>N</given-names> </name><name name-style="western"><surname>Etain</surname><given-names>B</given-names> </name><etal/></person-group><article-title>Insomnia and hypersomnia in major depressive episode: prevalence, sociodemographic characteristics and psychiatric comorbidity in a population-based study</article-title><source>J Affect Disord</source><year>2018</year><month>01</month><volume>226</volume><fpage>132</fpage><lpage>141</lpage><pub-id pub-id-type="doi">10.1016/j.jad.2017.09.032</pub-id></nlm-citation></ref><ref id="ref6"><label>6</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Morin</surname><given-names>CM</given-names> </name><name name-style="western"><surname>Jarrin</surname><given-names>DC</given-names> </name></person-group><article-title>Epidemiology of insomnia: prevalence, course, risk factors, and public health burden</article-title><source>Sleep Med Clin</source><year>2013</year><volume>8</volume><issue>3</issue><pub-id pub-id-type="doi">10.1016/j.jsmc.2013.05.002</pub-id><pub-id pub-id-type="medline">35659072</pub-id></nlm-citation></ref><ref id="ref7"><label>7</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Young</surname><given-names>TB</given-names> </name></person-group><article-title>Epidemiology of daytime sleepiness: definitions, symptomatology, and prevalence</article-title><source>J Clin Psychiatry</source><year>2004</year><volume>65 Suppl 16</volume><issue>Suppl 16</issue><fpage>12</fpage><lpage>16</lpage><pub-id pub-id-type="medline">15575799</pub-id></nlm-citation></ref><ref id="ref8"><label>8</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Senaratna</surname><given-names>CV</given-names> </name><name name-style="western"><surname>Perret</surname><given-names>JL</given-names> </name><name name-style="western"><surname>Lodge</surname><given-names>CJ</given-names> </name><etal/></person-group><article-title>Prevalence of obstructive sleep apnea in the general population: a systematic review</article-title><source>Sleep Med Rev</source><year>2017</year><month>08</month><volume>34</volume><fpage>70</fpage><lpage>81</lpage><pub-id pub-id-type="doi">10.1016/j.smrv.2016.07.002</pub-id></nlm-citation></ref><ref id="ref9"><label>9</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Rundo</surname><given-names>JV</given-names> </name><name name-style="western"><surname>Downey</surname><given-names>RI</given-names> </name></person-group><article-title>Polysomnography</article-title><source>Handb Clin Neurol</source><year>2019</year><volume>160</volume><fpage>381</fpage><lpage>392</lpage><pub-id pub-id-type="doi">10.1016/B978-0-444-64032-1.00025-4</pub-id><pub-id pub-id-type="medline">31277862</pub-id></nlm-citation></ref><ref id="ref10"><label>10</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Rajaratnam</surname><given-names>SMW</given-names> </name><name name-style="western"><surname>Barger</surname><given-names>LK</given-names> </name><name name-style="western"><surname>Lockley</surname><given-names>SW</given-names> </name><etal/></person-group><article-title>Sleep disorders, health, and safety in police officers</article-title><source>JAMA</source><year>2011</year><month>12</month><day>21</day><volume>306</volume><issue>23</issue><fpage>2567</fpage><lpage>2578</lpage><pub-id pub-id-type="doi">10.1001/jama.2011.1851</pub-id></nlm-citation></ref><ref id="ref11"><label>11</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Bloch</surname><given-names>KE</given-names> </name></person-group><article-title>Polysomnography: a systematic review</article-title><source>Technol Health Care</source><year>1997</year><month>10</month><volume>5</volume><issue>4</issue><fpage>285</fpage><lpage>305</lpage><pub-id pub-id-type="doi">10.3233/THC-1997-5403</pub-id><pub-id pub-id-type="medline">9429270</pub-id></nlm-citation></ref><ref id="ref12"><label>12</label><nlm-citation citation-type="book"><person-group person-group-type="author"><name name-style="western"><surname>Keenan</surname><given-names>SA</given-names> </name></person-group><person-group person-group-type="editor"><name name-style="western"><surname>Chokroverty</surname><given-names>S</given-names> </name></person-group><article-title>Polysomnographic technique: an overview</article-title><source>Sleep Disorders Medicine: Basic Science, Technical Considerations, and Clinical Aspects</source><year>1994</year><publisher-name>Butterworth-Heinemann</publisher-name><fpage>79</fpage><lpage>94</lpage><pub-id pub-id-type="doi">10.1016/B978-0-7506-9002-7.50011-2</pub-id></nlm-citation></ref><ref id="ref13"><label>13</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Kang</surname><given-names>SG</given-names> </name><name name-style="western"><surname>Kang</surname><given-names>JM</given-names> </name><name name-style="western"><surname>Ko</surname><given-names>KP</given-names> </name><name name-style="western"><surname>Park</surname><given-names>SC</given-names> </name><name name-style="western"><surname>Mariani</surname><given-names>S</given-names> </name><name name-style="western"><surname>Weng</surname><given-names>J</given-names> </name></person-group><article-title>Validity of a commercial wearable sleep tracker in adult insomnia disorder patients and good sleepers</article-title><source>J Psychosom Res</source><year>2017</year><month>06</month><volume>97</volume><fpage>38</fpage><lpage>44</lpage><pub-id pub-id-type="doi">10.1016/j.jpsychores.2017.03.009</pub-id></nlm-citation></ref><ref id="ref14"><label>14</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Lechat</surname><given-names>B</given-names> </name><name name-style="western"><surname>Scott</surname><given-names>H</given-names> </name><name name-style="western"><surname>Manners</surname><given-names>J</given-names> </name><etal/></person-group><article-title>Multi-night measurement for diagnosis and simplified monitoring of obstructive sleep apnoea</article-title><source>Sleep Med Rev</source><year>2023</year><month>12</month><volume>72</volume><fpage>101843</fpage><pub-id pub-id-type="doi">10.1016/j.smrv.2023.101843</pub-id></nlm-citation></ref><ref id="ref15"><label>15</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Toussaint</surname><given-names>M</given-names> </name><name name-style="western"><surname>Luthringer</surname><given-names>R</given-names> </name><name name-style="western"><surname>Schaltenbrand</surname><given-names>N</given-names> </name><etal/></person-group><article-title>First-night effect in normal subjects and psychiatric inpatients</article-title><source>Sleep</source><year>1995</year><month>07</month><volume>18</volume><issue>6</issue><fpage>463</fpage><lpage>469</lpage><pub-id pub-id-type="doi">10.1093/sleep/18.6.463</pub-id><pub-id pub-id-type="medline">7481418</pub-id></nlm-citation></ref><ref id="ref16"><label>16</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Smith</surname><given-names>MT</given-names> </name><name name-style="western"><surname>McCrae</surname><given-names>CS</given-names> </name><name name-style="western"><surname>Cheung</surname><given-names>J</given-names> </name><etal/></person-group><article-title>Use of actigraphy for the evaluation of sleep disorders and circadian rhythm sleep-wake disorders: an American Academy of Sleep Medicine systematic review, meta-analysis, and GRADE assessment</article-title><source>J Clin Sleep Med</source><year>2018</year><month>07</month><day>15</day><volume>14</volume><issue>07</issue><fpage>1209</fpage><lpage>1230</lpage><pub-id pub-id-type="doi">10.5664/jcsm.7228</pub-id></nlm-citation></ref><ref id="ref17"><label>17</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Kapur</surname><given-names>VK</given-names> </name><name name-style="western"><surname>Auckley</surname><given-names>DH</given-names> </name><name name-style="western"><surname>Chowdhuri</surname><given-names>S</given-names> </name><etal/></person-group><article-title>Clinical practice guideline for diagnostic testing for adult obstructive sleep apnea: an American Academy of Sleep Medicine clinical practice guideline</article-title><source>J Clin Sleep Med</source><year>2017</year><month>03</month><day>15</day><volume>13</volume><issue>03</issue><fpage>479</fpage><lpage>504</lpage><pub-id pub-id-type="doi">10.5664/jcsm.6506</pub-id></nlm-citation></ref><ref id="ref18"><label>18</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Braun</surname><given-names>M</given-names> </name><name name-style="western"><surname>Stockhoff</surname><given-names>M</given-names> </name><name name-style="western"><surname>Tijssen</surname><given-names>M</given-names> </name><name name-style="western"><surname>Dietz-Terjung</surname><given-names>S</given-names> </name><name name-style="western"><surname>Coughlin</surname><given-names>S</given-names> </name><name name-style="western"><surname>Sch&#x00F6;bel</surname><given-names>C</given-names> </name></person-group><article-title>A systematic review on the technical feasibility of home-polysomnography for diagnosis of sleep disorders in adults</article-title><source>Curr Sleep Medicine Rep</source><year>2024</year><month>06</month><day>1</day><volume>10</volume><issue>2</issue><fpage>276</fpage><lpage>288</lpage><pub-id pub-id-type="doi">10.1007/s40675-024-00301-z</pub-id></nlm-citation></ref><ref id="ref19"><label>19</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Mykytyn</surname><given-names>IJ</given-names> </name><name name-style="western"><surname>Sajkov</surname><given-names>D</given-names> </name><name name-style="western"><surname>Neill</surname><given-names>AM</given-names> </name><name name-style="western"><surname>Mc Evoy</surname><given-names>RD</given-names> </name></person-group><article-title>Portable computerized polysomnography in attended and unattended settings</article-title><source>Chest</source><year>1999</year><month>01</month><volume>115</volume><issue>1</issue><fpage>114</fpage><lpage>122</lpage><pub-id pub-id-type="doi">10.1378/chest.115.1.114</pub-id></nlm-citation></ref><ref id="ref20"><label>20</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Andrade</surname><given-names>L</given-names> </name><name name-style="western"><surname>Paiva</surname><given-names>T</given-names> </name></person-group><article-title>Ambulatory versus laboratory polysomnography in obstructive sleep apnea: comparative assessment of quality, clinical efficacy, treatment compliance, and quality of life</article-title><source>J Clin Sleep Med</source><year>2018</year><month>08</month><day>15</day><volume>14</volume><issue>8</issue><fpage>1323</fpage><lpage>1331</lpage><pub-id pub-id-type="doi">10.5664/jcsm.7264</pub-id><pub-id pub-id-type="medline">30092885</pub-id></nlm-citation></ref><ref id="ref21"><label>21</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Van de Water</surname><given-names>ATM</given-names> </name><name name-style="western"><surname>Holmes</surname><given-names>A</given-names> </name><name name-style="western"><surname>Hurley</surname><given-names>DA</given-names> </name></person-group><article-title>Objective measurements of sleep for non-laboratory settings as alternatives to polysomnography &#x2013; a systematic review</article-title><source>J Sleep Res</source><year>2011</year><month>03</month><volume>20</volume><issue>1 Pt 2</issue><fpage>183</fpage><lpage>200</lpage><pub-id pub-id-type="doi">10.1111/j.1365-2869.2009.00814.x</pub-id><pub-id pub-id-type="medline">20374444</pub-id></nlm-citation></ref><ref id="ref22"><label>22</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Pan</surname><given-names>Q</given-names> </name><name name-style="western"><surname>Brulin</surname><given-names>D</given-names> </name><name name-style="western"><surname>Campo</surname><given-names>E</given-names> </name></person-group><article-title>Current status and future challenges of sleep monitoring systems: systematic review</article-title><source>JMIR Biomed Eng</source><year>2020</year><month>08</month><day>26</day><volume>5</volume><issue>1</issue><fpage>e20921</fpage><pub-id pub-id-type="doi">10.2196/20921</pub-id></nlm-citation></ref><ref id="ref23"><label>23</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Vitazkova</surname><given-names>D</given-names> </name><name name-style="western"><surname>Kosnacova</surname><given-names>H</given-names> </name><name name-style="western"><surname>Turonova</surname><given-names>D</given-names> </name><etal/></person-group><article-title>Transforming sleep monitoring: review of wearable and remote devices advancing home polysomnography and their role in predicting neurological disorders</article-title><source>Biosensors (Basel)</source><year>2025</year><month>02</month><day>17</day><volume>15</volume><issue>2</issue><fpage>117</fpage><pub-id pub-id-type="doi">10.3390/bios15020117</pub-id><pub-id pub-id-type="medline">39997019</pub-id></nlm-citation></ref><ref id="ref24"><label>24</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Sivertsen</surname><given-names>B</given-names> </name><name name-style="western"><surname>Omvik</surname><given-names>S</given-names> </name><name name-style="western"><surname>Havik</surname><given-names>OE</given-names> </name><etal/></person-group><article-title>A comparison of actigraphy and polysomnography in older adults treated for chronic primary insomnia</article-title><source>Sleep</source><year>2006</year><month>10</month><volume>29</volume><issue>10</issue><fpage>1353</fpage><lpage>1358</lpage><pub-id pub-id-type="doi">10.1093/sleep/29.10.1353</pub-id></nlm-citation></ref><ref id="ref25"><label>25</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Paquet</surname><given-names>J</given-names> </name><name name-style="western"><surname>Kawinska</surname><given-names>A</given-names> </name><name name-style="western"><surname>Carrier</surname><given-names>J</given-names> </name></person-group><article-title>Wake detection capacity of actigraphy during sleep</article-title><source>Sleep</source><year>2007</year><month>10</month><volume>30</volume><issue>10</issue><fpage>1362</fpage><lpage>1369</lpage><pub-id pub-id-type="doi">10.1093/sleep/30.10.1362</pub-id><pub-id pub-id-type="medline">17969470</pub-id></nlm-citation></ref><ref id="ref26"><label>26</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>de Zambotti</surname><given-names>M</given-names> </name><name name-style="western"><surname>Goldstein</surname><given-names>C</given-names> </name><name name-style="western"><surname>Cook</surname><given-names>J</given-names> </name><etal/></person-group><article-title>State of the science and recommendations for using wearable technology in sleep and circadian research</article-title><source>Sleep</source><year>2024</year><month>04</month><day>12</day><volume>47</volume><issue>4</issue><fpage>38149978</fpage><pub-id pub-id-type="doi">10.1093/sleep/zsad325</pub-id></nlm-citation></ref><ref id="ref27"><label>27</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Kolla</surname><given-names>BP</given-names> </name><name name-style="western"><surname>Mansukhani</surname><given-names>S</given-names> </name><name name-style="western"><surname>Mansukhani</surname><given-names>MP</given-names> </name></person-group><article-title>Consumer sleep tracking devices: a review of mechanisms, validity and utility</article-title><source>Expert Rev Med Devices</source><year>2016</year><month>05</month><volume>13</volume><issue>5</issue><fpage>497</fpage><lpage>506</lpage><pub-id pub-id-type="doi">10.1586/17434440.2016.1171708</pub-id><pub-id pub-id-type="medline">27043070</pub-id></nlm-citation></ref><ref id="ref28"><label>28</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Edouard</surname><given-names>P</given-names> </name><name name-style="western"><surname>Campo</surname><given-names>D</given-names> </name><name name-style="western"><surname>Bartet</surname><given-names>P</given-names> </name><etal/></person-group><article-title>Validation of the Withings Sleep Analyzer, an under-the-mattress device for the detection of moderate-severe sleep apnea syndrome</article-title><source>J Clin Sleep Med</source><year>2021</year><month>06</month><volume>17</volume><issue>6</issue><fpage>1217</fpage><lpage>1227</lpage><pub-id pub-id-type="doi">10.5664/jcsm.9168</pub-id></nlm-citation></ref><ref id="ref29"><label>29</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Lechat</surname><given-names>B</given-names> </name><name name-style="western"><surname>Naik</surname><given-names>G</given-names> </name><name name-style="western"><surname>Reynolds</surname><given-names>A</given-names> </name><etal/></person-group><article-title>Multinight prevalence, variability, and diagnostic misclassification of obstructive sleep apnea</article-title><source>Am J Respir Crit Care Med</source><year>2022</year><month>03</month><day>1</day><volume>205</volume><issue>5</issue><fpage>563</fpage><lpage>569</lpage><pub-id pub-id-type="doi">10.1164/rccm.202107-1761OC</pub-id></nlm-citation></ref><ref id="ref30"><label>30</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>G Ravindran</surname><given-names>KK</given-names> </name><name name-style="western"><surname>della Monica</surname><given-names>C</given-names> </name><name name-style="western"><surname>Atzori</surname><given-names>G</given-names> </name><etal/></person-group><article-title>Reliable contactless monitoring of heart rate, breathing rate, and breathing disturbance during sleep in aging: digital health technology evaluation study.</article-title><source>JMIR Mhealth Uhealth</source><year>2024</year><volume>12</volume><fpage>e53643</fpage><pub-id pub-id-type="doi">10.2196/53643</pub-id></nlm-citation></ref><ref id="ref31"><label>31</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Jagielski</surname><given-names>JT</given-names> </name><name name-style="western"><surname>Bibi</surname><given-names>N</given-names> </name><name name-style="western"><surname>Gay</surname><given-names>PC</given-names> </name><etal/></person-group><article-title>Evaluating an under-mattress sleep monitor compared to a peripheral arterial tonometry home sleep apnea test device in the diagnosis of obstructive sleep apnea</article-title><source>Sleep Breath</source><year>2023</year><month>08</month><volume>27</volume><issue>4</issue><fpage>1433</fpage><lpage>1441</lpage><pub-id pub-id-type="doi">10.1007/s11325-022-02751-7</pub-id></nlm-citation></ref><ref id="ref32"><label>32</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Huyett</surname><given-names>P</given-names> </name><name name-style="western"><surname>Yu</surname><given-names>PK</given-names> </name><name name-style="western"><surname>Kent</surname><given-names>D</given-names> </name><etal/></person-group><article-title>Comparison of home sleep devices and sleep study testing in hypoglossal nerve stimulation patients</article-title><source>Laryngoscope</source><year>2025</year><month>01</month><volume>135</volume><issue>1</issue><fpage>469</fpage><lpage>477</lpage><pub-id pub-id-type="doi">10.1002/lary.31710</pub-id><pub-id pub-id-type="medline">39162306</pub-id></nlm-citation></ref><ref id="ref33"><label>33</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Ravindran</surname><given-names>KKG</given-names> </name><name name-style="western"><surname>della Monica</surname><given-names>C</given-names> </name><name name-style="western"><surname>Atzori</surname><given-names>G</given-names> </name><etal/></person-group><article-title>Contactless and longitudinal monitoring of nocturnal sleep and daytime naps in older men and women: a digital health technology evaluation study</article-title><source>Sleep</source><year>2023</year><month>10</month><day>11</day><volume>46</volume><issue>10</issue><fpage>zsad194</fpage><pub-id pub-id-type="doi">10.1093/sleep/zsad194</pub-id></nlm-citation></ref><ref id="ref34"><label>34</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Yang</surname><given-names>RY</given-names> </name><name name-style="western"><surname>Bendjoudi</surname><given-names>A</given-names> </name><name name-style="western"><surname>Buard</surname><given-names>N</given-names> </name><name name-style="western"><surname>Boutouyrie</surname><given-names>P</given-names> </name></person-group><article-title>Pneumatic sensor for cardiorespiratory monitoring during sleep</article-title><source>Biomed Phys Eng Express</source><year>2019</year><volume>5</volume><issue>5</issue><fpage>055014</fpage><pub-id pub-id-type="doi">10.1088/2057-1976/ab3ac9</pub-id></nlm-citation></ref><ref id="ref35"><label>35</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Hedner</surname><given-names>J</given-names> </name><name name-style="western"><surname>White</surname><given-names>DP</given-names> </name><name name-style="western"><surname>Malhotra</surname><given-names>A</given-names> </name><etal/></person-group><article-title>Sleep staging based on autonomic signals: a multi-center validation study</article-title><source>J Clin Sleep Med</source><year>2011</year><month>06</month><day>15</day><volume>7</volume><issue>3</issue><fpage>301</fpage><lpage>306</lpage><pub-id pub-id-type="doi">10.5664/JCSM.1078</pub-id><pub-id pub-id-type="medline">21677901</pub-id></nlm-citation></ref><ref id="ref36"><label>36</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Toften</surname><given-names>S</given-names> </name><name name-style="western"><surname>Pallesen</surname><given-names>S</given-names> </name><name name-style="western"><surname>Hrozanova</surname><given-names>M</given-names> </name><name name-style="western"><surname>Moen</surname><given-names>F</given-names> </name><name name-style="western"><surname>Gr&#x00F8;nli</surname><given-names>J</given-names> </name></person-group><article-title>Validation of sleep stage classification using non-contact radar technology and machine learning (Somnofy&#x00AE;)</article-title><source>Sleep Med</source><year>2020</year><month>11</month><volume>75</volume><fpage>54</fpage><lpage>61</lpage><pub-id pub-id-type="doi">10.1016/j.sleep.2020.02.022</pub-id></nlm-citation></ref><ref id="ref37"><label>37</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Chinoy</surname><given-names>ED</given-names> </name><name name-style="western"><surname>Cuellar</surname><given-names>JA</given-names> </name><name name-style="western"><surname>Huwa</surname><given-names>KE</given-names> </name><etal/></person-group><article-title>Performance of seven consumer sleep-tracking devices compared with polysomnography</article-title><source>Sleep</source><year>2021</year><month>05</month><day>14</day><volume>44</volume><issue>5</issue><fpage>zsaa291</fpage><pub-id pub-id-type="doi">10.1093/sleep/zsaa291</pub-id><pub-id pub-id-type="medline">33378539</pub-id></nlm-citation></ref><ref id="ref38"><label>38</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Kainec</surname><given-names>KA</given-names> </name><name name-style="western"><surname>Caccavaro</surname><given-names>J</given-names> </name><name name-style="western"><surname>Barnes</surname><given-names>M</given-names> </name><name name-style="western"><surname>Hoff</surname><given-names>C</given-names> </name><name name-style="western"><surname>Berlin</surname><given-names>A</given-names> </name><name name-style="western"><surname>Spencer</surname><given-names>RMC</given-names> </name></person-group><article-title>Evaluating accuracy in five commercial sleep-tracking devices compared to research-grade actigraphy and polysomnography</article-title><source>Sensors (Basel)</source><year>2024</year><volume>24</volume><issue>2</issue><fpage>635</fpage><pub-id pub-id-type="doi">10.3390/s24020635</pub-id></nlm-citation></ref><ref id="ref39"><label>39</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Nelson</surname><given-names>BW</given-names> </name><name name-style="western"><surname>Saeb</surname><given-names>S</given-names> </name><name name-style="western"><surname>Barman</surname><given-names>P</given-names> </name><etal/></person-group><article-title>Performance evaluation of the verily numetric watch sleep suite for digital sleep assessment against in-lab polysomnography</article-title><source>J Sleep Res</source><year>2025</year><month>10</month><volume>34</volume><issue>5</issue><fpage>e70036</fpage><pub-id pub-id-type="doi">10.1111/jsr.70036</pub-id><pub-id pub-id-type="medline">40170300</pub-id></nlm-citation></ref><ref id="ref40"><label>40</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Willoughby</surname><given-names>AR</given-names> </name><name name-style="western"><surname>Golkashani</surname><given-names>HA</given-names> </name><name name-style="western"><surname>Ghorbani</surname><given-names>S</given-names> </name><etal/></person-group><article-title>Performance of wearable sleep trackers during nocturnal sleep and periods of simulated real-world smartphone use</article-title><source>Sleep Health</source><year>2024</year><month>06</month><volume>10</volume><issue>3</issue><fpage>356</fpage><lpage>368</lpage><pub-id pub-id-type="doi">10.1016/j.sleh.2024.02.007</pub-id><pub-id pub-id-type="medline">38570223</pub-id></nlm-citation></ref><ref id="ref41"><label>41</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Benedetti</surname><given-names>D</given-names> </name><name name-style="western"><surname>Menghini</surname><given-names>L</given-names> </name><name name-style="western"><surname>Vallat</surname><given-names>R</given-names> </name><etal/></person-group><article-title>Call to action: an open-source pipeline for standardized performance evaluation of sleep-tracking technology</article-title><source>Sleep</source><year>2023</year><month>02</month><day>8</day><volume>46</volume><issue>2</issue><fpage>zsac304</fpage><pub-id pub-id-type="doi">10.1093/sleep/zsac304</pub-id><pub-id pub-id-type="medline">36611112</pub-id></nlm-citation></ref><ref id="ref42"><label>42</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Menghini</surname><given-names>L</given-names> </name><name name-style="western"><surname>Cellini</surname><given-names>N</given-names> </name><name name-style="western"><surname>Goldstone</surname><given-names>A</given-names> </name><name name-style="western"><surname>Baker</surname><given-names>FC</given-names> </name><name name-style="western"><surname>de Zambotti</surname><given-names>M</given-names> </name></person-group><article-title>A standardized framework for testing the performance of sleep-tracking technology: step-by-step guidelines and open-source code</article-title><source>Sleep</source><year>2021</year><month>02</month><day>12</day><volume>44</volume><issue>2</issue><fpage>zsaa170</fpage><pub-id pub-id-type="doi">10.1093/sleep/zsaa170</pub-id><pub-id pub-id-type="medline">32882005</pub-id></nlm-citation></ref><ref id="ref43"><label>43</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Chee</surname><given-names>MWL</given-names> </name><name name-style="western"><surname>Baumert</surname><given-names>M</given-names> </name><name name-style="western"><surname>Scott</surname><given-names>H</given-names> </name><etal/></person-group><article-title>World Sleep Society recommendations for the use of wearable consumer health trackers that monitor sleep</article-title><source>Sleep Med</source><year>2025</year><month>07</month><volume>131</volume><fpage>106506</fpage><pub-id pub-id-type="doi">10.1016/j.sleep.2025.106506</pub-id></nlm-citation></ref><ref id="ref44"><label>44</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Miller</surname><given-names>DJ</given-names> </name><name name-style="western"><surname>Sargent</surname><given-names>C</given-names> </name><name name-style="western"><surname>Roach</surname><given-names>GD</given-names> </name></person-group><article-title>A validation of six wearable devices for estimating sleep, heart rate and heart rate variability in healthy adults</article-title><source>Sensors (Basel)</source><year>2022</year><month>08</month><day>22</day><volume>22</volume><issue>16</issue><fpage>6317</fpage><pub-id pub-id-type="doi">10.3390/s22166317</pub-id><pub-id pub-id-type="medline">36016077</pub-id></nlm-citation></ref><ref id="ref45"><label>45</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Birrer</surname><given-names>V</given-names> </name><name name-style="western"><surname>Elgendi</surname><given-names>M</given-names> </name><name name-style="western"><surname>Lambercy</surname><given-names>O</given-names> </name><name name-style="western"><surname>Menon</surname><given-names>C</given-names> </name></person-group><article-title>Evaluating reliability in wearable devices for sleep staging</article-title><source>NPJ Digit Med</source><year>2024</year><month>03</month><day>18</day><volume>7</volume><issue>1</issue><fpage>74</fpage><pub-id pub-id-type="doi">10.1038/s41746-024-01016-9</pub-id><pub-id pub-id-type="medline">38499793</pub-id></nlm-citation></ref><ref id="ref46"><label>46</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Yuan</surname><given-names>H</given-names> </name><name name-style="western"><surname>Hill</surname><given-names>EA</given-names> </name><name name-style="western"><surname>Kyle</surname><given-names>SD</given-names> </name><name name-style="western"><surname>Doherty</surname><given-names>A</given-names> </name></person-group><article-title>A systematic review of the performance of actigraphy in measuring sleep stages</article-title><source>J Sleep Res</source><year>2024</year><month>10</month><volume>33</volume><issue>5</issue><fpage>e14143</fpage><pub-id pub-id-type="doi">10.1111/jsr.14143</pub-id><pub-id pub-id-type="medline">38384163</pub-id></nlm-citation></ref><ref id="ref47"><label>47</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Imtiaz</surname><given-names>SA</given-names> </name></person-group><article-title>A systematic review of sensing technologies for wearable sleep staging</article-title><source>Sensors (Basel)</source><year>2021</year><month>01</month><volume>21</volume><issue>5</issue><fpage>1562</fpage><pub-id pub-id-type="doi">10.3390/s21051562</pub-id></nlm-citation></ref><ref id="ref48"><label>48</label><nlm-citation citation-type="book"><person-group person-group-type="author"><name name-style="western"><surname>Berry</surname><given-names>RB</given-names> </name></person-group><source>Fundamentals of Sleep Medicine</source><year>2012</year><publisher-name>Elsevier</publisher-name><pub-id pub-id-type="other">9781437703269</pub-id></nlm-citation></ref><ref id="ref49"><label>49</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Buysse</surname><given-names>DJ</given-names> </name><name name-style="western"><surname>Reynolds</surname><given-names>CF</given-names>  <suffix>III</suffix></name><name name-style="western"><surname>Monk</surname><given-names>TH</given-names> </name><name name-style="western"><surname>Berman</surname><given-names>SR</given-names> </name><name name-style="western"><surname>Kupfer</surname><given-names>DJ</given-names> </name></person-group><article-title>The Pittsburgh Sleep Quality Index: a new instrument for psychiatric practice and research</article-title><source>Psychiatry Res</source><year>1989</year><month>05</month><volume>28</volume><issue>2</issue><fpage>193</fpage><lpage>213</lpage><pub-id pub-id-type="doi">10.1016/0165-1781(89)90047-4</pub-id><pub-id pub-id-type="medline">2748771</pub-id></nlm-citation></ref><ref id="ref50"><label>50</label><nlm-citation citation-type="book"><person-group person-group-type="author"><name name-style="western"><surname>Berry</surname><given-names>RB</given-names> </name><name name-style="western"><surname>Brooks</surname><given-names>R</given-names> </name><name name-style="western"><surname>Gamaldo</surname><given-names>CE</given-names> </name><name name-style="western"><surname>Harding</surname><given-names>SM</given-names> </name><name name-style="western"><surname>Marcus</surname><given-names>CL</given-names> </name><name name-style="western"><surname>Vaughn</surname><given-names>BV</given-names> </name></person-group><source>The AASM Manual for the Scoring of Sleep and Associated Events: Rules, Terminology and Technical Specifications</source><year>2015</year><access-date>2026-02-14</access-date><publisher-name>American Academy of Sleep Medicine</publisher-name><comment><ext-link ext-link-type="uri" xlink:href="https://aasm.org/resources/pdf/scoring-manual-preface.pdf">https://aasm.org/resources/pdf/scoring-manual-preface.pdf</ext-link></comment></nlm-citation></ref><ref id="ref51"><label>51</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Schmidt</surname><given-names>M</given-names> </name><name name-style="western"><surname>Schumann</surname><given-names>A</given-names> </name><name name-style="western"><surname>M&#x00FC;ller</surname><given-names>J</given-names> </name><name name-style="western"><surname>B&#x00E4;r</surname><given-names>KJ</given-names> </name><name name-style="western"><surname>Rose</surname><given-names>G</given-names> </name></person-group><article-title>ECG derived respiration: comparison of time-domain approaches and application to altered breathing patterns of patients with schizophrenia</article-title><source>Physiol Meas</source><year>2017</year><month>04</month><day>1</day><volume>38</volume><issue>4</issue><fpage>601</fpage><lpage>615</lpage><pub-id pub-id-type="doi">10.1088/1361-6579/aa5feb</pub-id></nlm-citation></ref><ref id="ref52"><label>52</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>de Zambotti</surname><given-names>M</given-names> </name><name name-style="western"><surname>Goldstone</surname><given-names>A</given-names> </name><name name-style="western"><surname>Claudatos</surname><given-names>S</given-names> </name><name name-style="western"><surname>Colrain</surname><given-names>IM</given-names> </name><name name-style="western"><surname>Baker</surname><given-names>FC</given-names> </name></person-group><article-title>A validation study of Fitbit Charge 2<sup>TM</sup> compared with polysomnography in adults</article-title><source>Chronobiol Int</source><year>2018</year><month>04</month><volume>35</volume><issue>4</issue><fpage>465</fpage><lpage>476</lpage><pub-id pub-id-type="doi">10.1080/07420528.2017.1413578</pub-id><pub-id pub-id-type="medline">29235907</pub-id></nlm-citation></ref><ref id="ref53"><label>53</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Lee</surname><given-names>YJ</given-names> </name><name name-style="western"><surname>Lee</surname><given-names>JY</given-names> </name><name name-style="western"><surname>Cho</surname><given-names>JH</given-names> </name><name name-style="western"><surname>Choi</surname><given-names>JH</given-names> </name></person-group><article-title>Interrater reliability of sleep stage scoring: a meta-analysis</article-title><source>J Clin Sleep Med</source><year>2022</year><month>01</month><volume>18</volume><issue>1</issue><fpage>193</fpage><lpage>202</lpage><pub-id pub-id-type="doi">10.5664/jcsm.9538</pub-id></nlm-citation></ref><ref id="ref54"><label>54</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Tal</surname><given-names>A</given-names> </name><name name-style="western"><surname>Shinar</surname><given-names>Z</given-names> </name><name name-style="western"><surname>Shaki</surname><given-names>D</given-names> </name><name name-style="western"><surname>Codish</surname><given-names>S</given-names> </name><name name-style="western"><surname>Goldbart</surname><given-names>A</given-names> </name></person-group><article-title>Validation of contact-free sleep monitoring device with comparison to polysomnography.</article-title><source>J Clin Sleep Med</source><year>2017</year><month>03</month><day>15</day><volume>13</volume><issue>3</issue><fpage>517</fpage><lpage>522</lpage><pub-id pub-id-type="doi">10.5664/jcsm.6514</pub-id><pub-id pub-id-type="medline">27998378</pub-id></nlm-citation></ref><ref id="ref55"><label>55</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Ding</surname><given-names>F</given-names> </name><name name-style="western"><surname>Cotton-Clay</surname><given-names>A</given-names> </name><name name-style="western"><surname>Fava</surname><given-names>L</given-names> </name><etal/></person-group><article-title>Polysomnographic validation of an under-mattress monitoring device in estimating sleep architecture and obstructive sleep apnea in adults</article-title><source>Sleep Med</source><year>2022</year><month>08</month><volume>96</volume><fpage>20</fpage><lpage>27</lpage><pub-id pub-id-type="doi">10.1016/j.sleep.2022.04.010</pub-id></nlm-citation></ref><ref id="ref56"><label>56</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Ellender</surname><given-names>CM</given-names> </name><name name-style="western"><surname>Zahir</surname><given-names>SF</given-names> </name><name name-style="western"><surname>Meaklim</surname><given-names>H</given-names> </name><name name-style="western"><surname>Joyce</surname><given-names>R</given-names> </name><name name-style="western"><surname>Cunnington</surname><given-names>D</given-names> </name><name name-style="western"><surname>Swieca</surname><given-names>J</given-names> </name></person-group><article-title>Prospective cohort study to evaluate the accuracy of sleep measurement by consumer-grade smart devices compared with polysomnography in a sleep disorders population</article-title><source>BMJ Open</source><year>2021</year><month>11</month><volume>11</volume><fpage>e044015</fpage><pub-id pub-id-type="doi">10.1136/bmjopen-2020-044015</pub-id></nlm-citation></ref><ref id="ref57"><label>57</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Hsiou</surname><given-names>DA</given-names> </name><name name-style="western"><surname>Gao</surname><given-names>C</given-names> </name><name name-style="western"><surname>Matlock</surname><given-names>RC</given-names> </name><name name-style="western"><surname>Scullin</surname><given-names>MK</given-names> </name></person-group><article-title>Validation of a nonwearable device in healthy adults with normal and short sleep durations</article-title><source>J Clin Sleep Med</source><year>2022</year><month>03</month><day>1</day><volume>18</volume><issue>3</issue><fpage>751</fpage><lpage>757</lpage><pub-id pub-id-type="doi">10.5664/jcsm.9700</pub-id><pub-id pub-id-type="medline">34608858</pub-id></nlm-citation></ref><ref id="ref58"><label>58</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Tuominen</surname><given-names>J</given-names> </name><name name-style="western"><surname>Peltola</surname><given-names>K</given-names> </name><name name-style="western"><surname>Saaresranta</surname><given-names>T</given-names> </name><name name-style="western"><surname>Valli</surname><given-names>K</given-names> </name></person-group><article-title>Sleep parameter assessment accuracy of a consumer home sleep monitoring ballistocardiograph beddit sleep tracker: a validation study.</article-title><source>J Clin Sleep Med</source><year>2019</year><month>03</month><day>15</day><volume>15</volume><issue>3</issue><fpage>483</fpage><lpage>487</lpage><pub-id pub-id-type="doi">10.5664/jcsm.7682</pub-id><pub-id pub-id-type="medline">30853052</pub-id></nlm-citation></ref><ref id="ref59"><label>59</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Kholghi</surname><given-names>M</given-names> </name><name name-style="western"><surname>Szollosi</surname><given-names>I</given-names> </name><name name-style="western"><surname>Hollamby</surname><given-names>M</given-names> </name><name name-style="western"><surname>Bradford</surname><given-names>D</given-names> </name><name name-style="western"><surname>Zhang</surname><given-names>Q</given-names> </name></person-group><article-title>A validation study of a ballistocardiograph sleep tracker against polysomnography</article-title><source>J Clin Sleep Med</source><year>2022</year><month>04</month><day>1</day><volume>18</volume><issue>4</issue><fpage>1203</fpage><lpage>1210</lpage><pub-id pub-id-type="doi">10.5664/jcsm.9754</pub-id><pub-id pub-id-type="medline">34705630</pub-id></nlm-citation></ref><ref id="ref60"><label>60</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Manners</surname><given-names>J</given-names> </name><name name-style="western"><surname>Kemps</surname><given-names>E</given-names> </name><name name-style="western"><surname>Lechat</surname><given-names>B</given-names> </name><name name-style="western"><surname>Catcheside</surname><given-names>P</given-names> </name><name name-style="western"><surname>Eckert</surname><given-names>DJ</given-names> </name><name name-style="western"><surname>Scott</surname><given-names>H</given-names> </name></person-group><article-title>Performance evaluation of an under-mattress sleep sensor versus polysomnography in &#x003E;&#x2009;400 nights with healthy and unhealthy sleep</article-title><source>J Sleep Res</source><year>2025</year><month>12</month><volume>34</volume><issue>6</issue><fpage>e14480</fpage><pub-id pub-id-type="doi">10.1111/jsr.14480</pub-id><pub-id pub-id-type="medline">40017337</pub-id></nlm-citation></ref><ref id="ref61"><label>61</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Kelly</surname><given-names>JM</given-names> </name><name name-style="western"><surname>Strecker</surname><given-names>RE</given-names> </name><name name-style="western"><surname>Bianchi</surname><given-names>MT</given-names> </name></person-group><article-title>Recent developments in home sleep-monitoring devices</article-title><source>ISRN Neurol</source><year>2012</year><month>10</month><day>14</day><volume>2012</volume><fpage>1</fpage><lpage>10</lpage><pub-id pub-id-type="doi">10.5402/2012/768794</pub-id></nlm-citation></ref><ref id="ref62"><label>62</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Byrt</surname><given-names>T</given-names> </name><name name-style="western"><surname>Bishop</surname><given-names>J</given-names> </name><name name-style="western"><surname>Carlin</surname><given-names>JB</given-names> </name></person-group><article-title>Bias, prevalence and kappa</article-title><source>J Clin Epidemiol</source><year>1993</year><month>05</month><volume>46</volume><issue>5</issue><fpage>423</fpage><lpage>429</lpage><pub-id pub-id-type="doi">10.1016/0895-4356(93)90018-v</pub-id><pub-id pub-id-type="medline">8501467</pub-id></nlm-citation></ref><ref id="ref63"><label>63</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Gj&#x00F8;rup</surname><given-names>T</given-names> </name></person-group><article-title>The kappa coefficient and the prevalence of a diagnosis</article-title><source>Methods Inf Med</source><year>1988</year><month>10</month><volume>27</volume><issue>4</issue><fpage>184</fpage><lpage>186</lpage><pub-id pub-id-type="doi">10.1055/s-0038-1635539</pub-id><pub-id pub-id-type="medline">3226333</pub-id></nlm-citation></ref><ref id="ref64"><label>64</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Pellegrini</surname><given-names>M</given-names> </name><name name-style="western"><surname>Lannin</surname><given-names>NA</given-names> </name><name name-style="western"><surname>Mychasiuk</surname><given-names>R</given-names> </name><name name-style="western"><surname>Graco</surname><given-names>M</given-names> </name><name name-style="western"><surname>Kramer</surname><given-names>SF</given-names> </name><name name-style="western"><surname>Giummarra</surname><given-names>MJ</given-names> </name></person-group><article-title>Measuring sleep quality in the hospital environment with wearable and non-wearable devices in adults with stroke undergoing inpatient rehabilitation.</article-title><source>Int J Environ Res Public Health</source><year>2023</year><month>02</month><day>23</day><volume>20</volume><issue>5</issue><fpage>3984</fpage><pub-id pub-id-type="doi">10.3390/ijerph20053984</pub-id><pub-id pub-id-type="medline">36900995</pub-id></nlm-citation></ref><ref id="ref65"><label>65</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Carney</surname><given-names>CE</given-names> </name><name name-style="western"><surname>Buysse</surname><given-names>DJ</given-names> </name><name name-style="western"><surname>Ancoli-Israel</surname><given-names>S</given-names> </name><etal/></person-group><article-title>The consensus sleep diary: standardizing prospective sleep self-monitoring</article-title><source>Sleep</source><year>2012</year><month>02</month><volume>35</volume><issue>2</issue><fpage>287</fpage><lpage>302</lpage><pub-id pub-id-type="doi">10.5665/sleep.1642</pub-id></nlm-citation></ref><ref id="ref66"><label>66</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Lechat</surname><given-names>B</given-names> </name><name name-style="western"><surname>Naik</surname><given-names>G</given-names> </name><name name-style="western"><surname>Appleton</surname><given-names>S</given-names> </name><etal/></person-group><article-title>Multi-night assessment of snoring is associated with hypertension independent of OSA severity [Abstract]</article-title><source>Am J Respir Crit Care Med</source><year>2023</year><volume>207</volume><fpage>A6200</fpage><pub-id pub-id-type="doi">10.1164/ajrccm-conference.2023.207.1_MeetingAbstracts.A6200</pub-id></nlm-citation></ref><ref id="ref67"><label>67</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>de Havenon</surname><given-names>A</given-names> </name><name name-style="western"><surname>Falcone</surname><given-names>G</given-names> </name><name name-style="western"><surname>Rivier</surname><given-names>C</given-names> </name><etal/></person-group><article-title>Impact of sleep quality and physical activity on blood pressure variability</article-title><source>PLoS ONE</source><year>2024</year><volume>19</volume><issue>4</issue><fpage>e0301631</fpage><pub-id pub-id-type="doi">10.1371/journal.pone.0301631</pub-id></nlm-citation></ref><ref id="ref68"><label>68</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Scott</surname><given-names>H</given-names> </name><name name-style="western"><surname>Lechat</surname><given-names>B</given-names> </name><name name-style="western"><surname>Guyett</surname><given-names>A</given-names> </name><etal/></person-group><article-title>Sleep irregularity is associated with hypertension: findings from over 2 million nights with a large global population sample</article-title><source>Hypertension</source><year>2023</year><month>05</month><volume>80</volume><issue>5</issue><fpage>1117</fpage><lpage>1126</lpage><pub-id pub-id-type="doi">10.1161/HYPERTENSIONAHA.122.20513</pub-id></nlm-citation></ref><ref id="ref69"><label>69</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Scott</surname><given-names>H</given-names> </name><name name-style="western"><surname>Naik</surname><given-names>G</given-names> </name><name name-style="western"><surname>Lechat</surname><given-names>B</given-names> </name><etal/></person-group><article-title>Are we getting enough sleep? Frequent irregular sleep found in an analysis of over 11 million nights of objective in-home sleep data</article-title><source>Sleep Health</source><year>2024</year><month>02</month><volume>10</volume><issue>1</issue><fpage>91</fpage><lpage>97</lpage><pub-id pub-id-type="doi">10.1016/j.sleh.2023.10.016</pub-id></nlm-citation></ref><ref id="ref70"><label>70</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Chapple</surname><given-names>C</given-names> </name><name name-style="western"><surname>Bliwise</surname><given-names>D</given-names> </name><name name-style="western"><surname>Maislisch</surname><given-names>L</given-names> </name><name name-style="western"><surname>Roitmann</surname><given-names>E</given-names> </name><name name-style="western"><surname>Burtea</surname><given-names>T</given-names> </name></person-group><article-title>Night-time voids, level of bother and sleep characteristics in a non-patient population of wearable devices users</article-title><source>Int J Clin Pract</source><year>2020</year><month>07</month><volume>74</volume><issue>7</issue><fpage>e13495</fpage><pub-id pub-id-type="doi">10.1111/ijcp.13495</pub-id><pub-id pub-id-type="medline">32100396</pub-id></nlm-citation></ref><ref id="ref71"><label>71</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Chaudhry</surname><given-names>FF</given-names> </name><name name-style="western"><surname>Danieletto</surname><given-names>M</given-names> </name><name name-style="western"><surname>Golden</surname><given-names>E</given-names> </name><etal/></person-group><article-title>Sleep in the natural environment: a pilot study</article-title><source>Sensors (Basel)</source><year>2020</year><volume>20</volume><issue>5</issue><fpage>1378</fpage><pub-id pub-id-type="doi">10.3390/s20051378</pub-id></nlm-citation></ref></ref-list><app-group><supplementary-material id="app1"><label>Multimedia Appendix 1</label><p>Details on methods and algorithm performance per sleep stage.</p><media xlink:href="humanfactors_v13i1e77033_app1.docx" xlink:title="DOCX File, 3319 KB"/></supplementary-material><supplementary-material id="app2"><label>Multimedia Appendix 2</label><p>Results of Kruskal-Wallis and Brown-Forsythe statistical tests followed by Holm-Bonferroni correction.</p><media xlink:href="humanfactors_v13i1e77033_app2.xlsx" xlink:title="XLSX File, 38 KB"/></supplementary-material><supplementary-material id="app3"><label>Multimedia Appendix 3</label><p>Comparison with previous research.</p><media xlink:href="humanfactors_v13i1e77033_app3.xlsx" xlink:title="XLSX File, 65 KB"/></supplementary-material></app-group></back></article>